Total
6763 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-50374 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation. | |||||
| CVE-2024-50373 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation. | |||||
| CVE-2024-50372 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation. | |||||
| CVE-2024-50371 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation. | |||||
| CVE-2024-50370 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation. | |||||
| CVE-2024-50369 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50368 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50367 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50366 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50365 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50364 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50363 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50362 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50361 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50360 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-50359 | 1 Advantech | 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more | 2026-06-17 | N/A | 7.2 HIGH |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands. | |||||
| CVE-2024-4965 | 1 Dlink | 2 Dar-7000, Dar-7000 Firmware | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This issue affects some unknown processing of the file /useratte/resmanage.php. The manipulation of the argument load leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264533 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced. | |||||
| CVE-2024-4884 | 1 Progress | 1 Whatsup Gold | 2026-06-17 | N/A | 9.8 CRITICAL |
| In WhatsUp Gold versions released before 2023.1.3, an unauthenticated Remote Code Execution vulnerability in Progress WhatsUpGold. The Apm.UI.Areas.APM.Controllers.CommunityController allows execution of commands with iisapppool\nmconsole privileges. | |||||
| CVE-2024-4883 | 1 Progress | 1 Whatsup Gold | 2026-06-17 | N/A | 9.8 CRITICAL |
| In WhatsUp Gold versions released before 2023.1.3, a Remote Code Execution issue exists in Progress WhatsUp Gold. This vulnerability allows an unauthenticated attacker to achieve the RCE as a service account through NmApi.exe. | |||||
| CVE-2024-4816 | 1 Ruijie | 54 Rg-uac 6000-cc, Rg-uac 6000-cc Firmware, Rg-uac 6000-e10 and 51 more | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| A vulnerability, which was classified as critical, was found in Ruijie RG-UAC up to 20240506. This affects an unknown part of the file /view/networkConfig/GRE/gre_add_commit.php. The manipulation of the argument name/remote/local/IP leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
