Filtered by vendor Rockwellautomation
Subscribe
Total
352 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2026-9128 | 1 Rockwellautomation | 1 Studio 5000 Logix Designer | 2026-08-25 | N/A | 7.5 HIGH |
| A code execution security issue exists within Studio 5000 Logix Designer® due to an unquoted search path in the External Tools configuration. The executable paths specified in the external tools configuration file are not properly quoted, and because these paths contain spaces, the operating system may resolve them to unintended executables placed earlier in the search order. If exploited, an attacker could plant a malicious executable in a location within the search path, resulting in arbitrary code execution with the same permissions of the user running the application. | |||||
| CVE-2026-9108 | 1 Rockwellautomation | 1 Studio 5000 Logix Designer | 2026-08-25 | N/A | 7.5 HIGH |
| A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution. | |||||
| CVE-2026-9127 | 1 Rockwellautomation | 1 Studio 5000 Logix Designer | 2026-08-25 | N/A | 7.5 HIGH |
| A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality. | |||||
| CVE-2026-8085 | 1 Rockwellautomation | 1 Arena | 2026-07-15 | N/A | 7.3 HIGH |
| A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the model.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. | |||||
| CVE-2026-8312 | 1 Rockwellautomation | 1 Arena | 2026-07-15 | N/A | 7.3 HIGH |
| A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. | |||||
| CVE-2026-8313 | 1 Rockwellautomation | 1 Arena | 2026-07-15 | N/A | 7.3 HIGH |
| A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the linker.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. | |||||
| CVE-2026-8314 | 1 Rockwellautomation | 1 Arena | 2026-07-15 | N/A | 7.3 HIGH |
| A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the siman.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. | |||||
| CVE-2025-9466 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP and CIP grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | |||||
| CVE-2025-9465 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | |||||
| CVE-2025-9464 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. This vulnerability is triggered during fuzzing of multiple CIP classes, which causes the CIP port to become unresponsive. | |||||
| CVE-2025-9364 | 1 Rockwellautomation | 1 Factorytalk Analytics Logixai | 2026-06-17 | N/A | 8.8 HIGH |
| An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data. | |||||
| CVE-2025-9283 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limits Storms tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | |||||
| CVE-2025-9282 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive limited storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | |||||
| CVE-2025-9281 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive step limit storm tests, the device reboots | |||||
| CVE-2025-9280 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. Fuzzing performed using Defensics causes the device to become unresponsive, requiring a reboot. | |||||
| CVE-2025-9279 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limit Storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | |||||
| CVE-2025-9278 | 1 Rockwellautomation | 2 Armorstart Lt, Armorstart Lt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. After running a Burp Suite active scan, the device loses ICMP connectivity, causing the web application to become inaccessible. | |||||
| CVE-2025-9166 | 1 Rockwellautomation | 2 Controllogix 5580, Controllogix 5580 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A denial-of-service security issue exists in the affected product and version. The security issue stems from the controller repeatedly attempting to forward messages. The issue could result in a major nonrecoverable fault on the controller. | |||||
| CVE-2025-9161 | 1 Rockwellautomation | 1 Factorytalk Optix | 2026-06-17 | N/A | 8.8 HIGH |
| A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution. | |||||
| CVE-2025-9068 | 1 Rockwellautomation | 1 Factorytalk Linx | 2026-06-17 | N/A | 7.8 HIGH |
| A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources. | |||||
