Filtered by vendor Siemens
Subscribe
Total
2206 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-32222 | 2 Nodejs, Siemens | 2 Node.js, Sinec Ins | 2026-06-17 | N/A | 5.3 MEDIUM |
| A cryptographic vulnerability exists on Node.js on linux in versions of 18.x prior to 18.40.0 which allowed a default path for openssl.cnf that might be accessible under some circumstances to a non-admin user instead of /etc/ssl as was the case in versions prior to the upgrade to OpenSSL 3. | |||||
| CVE-2022-32215 | 6 Debian, Fedoraproject, Llhttp and 3 more | 6 Debian Linux, Fedora, Llhttp and 3 more | 2026-06-17 | N/A | 6.5 MEDIUM |
| The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does not correctly handle multi-line Transfer-Encoding headers. This can lead to HTTP Request Smuggling (HRS). | |||||
| CVE-2022-32213 | 6 Debian, Fedoraproject, Llhttp and 3 more | 6 Debian Linux, Fedora, Llhttp and 3 more | 2026-06-17 | N/A | 6.5 MEDIUM |
| The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does not correctly parse and validate Transfer-Encoding headers and can lead to HTTP Request Smuggling (HRS). | |||||
| CVE-2022-32212 | 4 Debian, Fedoraproject, Nodejs and 1 more | 4 Debian Linux, Fedora, Node.js and 1 more | 2026-06-17 | N/A | 8.1 HIGH |
| A OS Command Injection vulnerability exists in Node.js versions <14.20.0, <16.20.0, <18.5.0 due to an insufficient IsAllowedHost check that can easily be bypassed because IsIPAddress does not properly check if an IP address is invalid before making DBS requests allowing rebinding attacks. | |||||
| CVE-2022-32145 | 1 Siemens | 1 Teamcenter Active Workspace | 2026-06-17 | 4.3 MEDIUM | 6.1 MEDIUM |
| A vulnerability has been identified in Teamcenter Active Workspace V5.2 (All versions < V5.2.9), Teamcenter Active Workspace V6.0 (All versions < V6.0.3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious code by tricking users into accessing a malicious link. | |||||
| CVE-2022-31812 | 1 Siemens | 1 Sipass Integrated | 2026-06-17 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18). Affected server applications contain an out of bounds read past the end of an allocated buffer while checking the integrity of incoming packets. This could allow an unauthenticated remote attacker to create a denial of service condition. | |||||
| CVE-2022-31807 | 1 Siemens | 4 Sipass Integrated Ac5102 \(acc-g2\), Sipass Integrated Ac5102 \(acc-g2\) Firmware, Sipass Integrated Acc-ap and 1 more | 2026-06-17 | N/A | 6.2 MEDIUM |
| A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly". | |||||
| CVE-2022-31766 | 1 Siemens | 32 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M804pb and 29 more | 2026-06-17 | N/A | 8.6 HIGH |
| A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.1.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.1.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.1.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.1.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.1.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.1.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.1.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.1.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.1.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.1.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.1.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.1.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.1.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.1.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.1.2), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions >= V1.1.0 < V3.0.0). Affected devices with TCP Event service enabled do not properly handle malformed packets. This could allow an unauthenticated remote attacker to cause a denial of service condition and reboot the device thus possibly affecting other network resources. | |||||
| CVE-2022-31765 | 1 Siemens | 372 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 369 more | 2026-06-17 | N/A | 8.8 HIGH |
| Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges. | |||||
| CVE-2022-31619 | 1 Siemens | 1 Teamcenter | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions < V13.1.0.9), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). Java EE Server Manager HTML Adaptor in Teamcenter consists of default hardcoded credentials. Access to the application allows a user to perform a series of actions that could potentially lead to remote code execution with elevated permissions. | |||||
| CVE-2022-31465 | 1 Siemens | 1 Xpedition Designer | 2026-06-17 | 4.6 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Xpedition Designer VX.2.10 (All versions < VX.2.10 Update 13), Xpedition Designer VX.2.11 (All versions < VX.2.11 Update 11), Xpedition Designer VX.2.12 (All versions < VX.2.12 Update 5), Xpedition Designer VX.2.13 (All versions < VX.2.13 Update 1). The affected application assigns improper access rights to the service executable. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges. | |||||
| CVE-2022-30938 | 1 Siemens | 6 En100 Ethernet Module, En100 Ethernet Module Dnp3 Ip Firmware, En100 Ethernet Module Iec 104 Firmware and 3 more | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition | |||||
| CVE-2022-30937 | 1 Siemens | 6 En100 Ethernet Module, En100 Ethernet Module Dnp3 Firmware, En100 Ethernet Module Iec 104 Firmware and 3 more | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition. | |||||
| CVE-2022-30694 | 1 Siemens | 223 6ag1151-8ab01-7ab0, 6ag1151-8ab01-7ab0 Firmware, 6ag1151-8fb01-2ab0 and 220 more | 2026-06-17 | N/A | 6.5 MEDIUM |
| The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. | |||||
| CVE-2022-30527 | 1 Siemens | 1 Sinec Nms | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application assigns improper access rights to specific folders containing executable files and libraries. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges. | |||||
| CVE-2022-30231 | 1 Siemens | 1 Sicam Gridedge Essential | 2026-06-17 | 4.0 MEDIUM | 4.9 MEDIUM |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve another user's password hash. | |||||
| CVE-2022-30230 | 1 Siemens | 1 Sicam Gridedge Essential | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions. | |||||
| CVE-2022-30229 | 1 Siemens | 1 Sicam Gridedge Essential | 2026-06-17 | 5.0 MEDIUM | 7.2 HIGH |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of a user, such as credentials, in case that user's id is known. | |||||
| CVE-2022-30228 | 1 Siemens | 1 Sicam Gridedge Essential | 2026-06-17 | 4.3 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could be executed. | |||||
| CVE-2022-2069 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2026-06-17 | N/A | 7.8 HIGH |
| The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. | |||||