CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-36140 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2026-06-17 N/A 6.8 MEDIUM
A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to stored cross-site scripting (XSS) attacks. This could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges than the attacker.
CVE-2024-35212 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 6.2 MEDIUM
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application lacks input validation due to which an attacker can gain access to the Database entries.
CVE-2024-35211 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 5.5 MEDIUM
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server, after a successful login, sets the session cookie on the browser, without applying any security attributes (such as “Secure”, “HttpOnly”, or “SameSite”).
CVE-2024-35210 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 5.1 MEDIUM
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is not enforcing HSTS. This could allow an attacker to perform downgrade attacks exposing confidential information.
CVE-2024-35209 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 6.2 MEDIUM
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server is allowing HTTP methods like PUT and Delete. This could allow an attacker to modify unauthorized files.
CVE-2024-35208 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 6.3 MEDIUM
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server stored the password in cleartext. This could allow attacker in a privileged position to obtain access passwords.
CVE-2024-35207 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
CVE-2024-35206 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 7.7 HIGH
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application does not expire the session. This could allow an attacker to get unauthorized access.
CVE-2024-34773 1 Siemens 1 Solid Edge Se2024 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 2). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-34772 1 Siemens 1 Solid Edge Se2024 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-34771 1 Siemens 1 Solid Edge Se2024 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 2). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-34086 1 Siemens 2 Jt2go, Teamcenter Visualization 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process.
CVE-2024-34085 1 Siemens 2 Jt2go, Teamcenter Visualization 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-34057 2 Siemens, Trianglemicroworks 9 Sicam A8000, Sicam A8000 Firmware, Sicam Egs and 6 more 2026-06-17 N/A 7.5 HIGH
Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.
CVE-2024-33654 1 Siemens 1 Simcenter Femap 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33653 1 Siemens 1 Simcenter Femap 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33577 1 Siemens 2 Simcenter Femap, Simcenter Nastran 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33493 1 Siemens 1 Solid Edge Se2024 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33492 1 Siemens 1 Solid Edge Se2024 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33491 1 Siemens 1 Solid Edge Se2024 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.