Filtered by vendor Siemens
Subscribe
Total
2206 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-47904 | 1 Siemens | 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges. | |||||
| CVE-2024-47903 | 1 Siemens | 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware | 2026-06-17 | N/A | 5.8 MEDIUM |
| A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices allows to write arbitrary files to the web server's DocumentRoot directory. | |||||
| CVE-2024-47902 | 1 Siemens | 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware | 2026-06-17 | N/A | 7.2 HIGH |
| A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level. | |||||
| CVE-2024-47901 | 1 Siemens | 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware | 2026-06-17 | N/A | 10.0 CRITICAL |
| A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges. | |||||
| CVE-2024-47808 | 1 Siemens | 1 Sinec Nms | 2026-06-17 | N/A | 8.4 HIGH |
| A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restrict the permissions of users to write to the filesystem of the host system. This could allow an authenticated medium-privileged attacker to write arbitrary content to any location in the filesystem of the host system. | |||||
| CVE-2024-47783 | 1 Siemens | 1 Siport | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in SIPORT (All versions < V3.4.0). The affected application improperly assigns file permissions to installation folders. This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges. | |||||
| CVE-2024-47565 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate that user input complies with a list of allowed values. This could allow an authenticated remote attacker to compromise the integrity of the configuration of the affected application. | |||||
| CVE-2024-47563 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 5.3 MEDIUM |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate a file path that is supplied to an endpoint intended to create CSR files. This could allow an unauthenticated remote attacker to create files in writable directories outside the intended location and thus compromise integrity of files in those writable directories. | |||||
| CVE-2024-47562 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command. This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS. | |||||
| CVE-2024-47553 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 9.9 CRITICAL |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ```ssmctl-client``` command. This could allow an authenticated, lowly privileged remote attacker to execute arbitrary code with root privileges on the underlying OS. | |||||
| CVE-2024-47196 | 1 Siemens | 2 Modelsim, Questa | 2026-06-17 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in ModelSim (All versions < V2025.2), Questa (All versions < V2025.2). vsimk.exe in affected applications allows a specific tcl file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vsimk.exe from a user-writable directory. | |||||
| CVE-2024-47195 | 1 Siemens | 2 Modelsim, Questa | 2026-06-17 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). gdb.exe in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch gdb.exe from a user-writable directory. | |||||
| CVE-2024-47194 | 1 Siemens | 2 Modelsim, Questa | 2026-06-17 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). vish2.exe in affected applications allows a specific DLL file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch vish2.exe from a user-writable directory. | |||||
| CVE-2024-47046 | 1 Siemens | 1 Simcenter Nastran | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to memory corruption while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-46894 | 1 Siemens | 1 Sinec Ins | 2026-06-17 | N/A | 6.3 MEDIUM |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate authorization of a user to query the "/api/sftp/users" endpoint. This could allow an authenticated remote attacker to gain knowledge about the list of configured users of the SFTP service and also modify that configuration. | |||||
| CVE-2024-46892 | 1 Siemens | 1 Sinec Ins | 2026-06-17 | N/A | 4.9 MEDIUM |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled. | |||||
| CVE-2024-46891 | 1 Siemens | 1 Sinec Ins | 2026-06-17 | N/A | 5.3 MEDIUM |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition. | |||||
| CVE-2024-46890 | 1 Siemens | 1 Sinec Ins | 2026-06-17 | N/A | 9.1 CRITICAL |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS. | |||||
| CVE-2024-46889 | 1 Siemens | 1 Sinec Ins | 2026-06-17 | N/A | 5.3 MEDIUM |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application uses hard-coded cryptographic key material to obfuscate configuration files. This could allow an attacker to learn that cryptographic key material through reverse engineering of the application binary and decrypt arbitrary backup files. | |||||
| CVE-2024-46888 | 1 Siemens | 1 Sinec Ins | 2026-06-17 | N/A | 9.9 CRITICAL |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths for SFTP-based file up- and downloads. This could allow an authenticated remote attacker to manipulate arbitrary files on the filesystem and achieve arbitrary code execution on the device. | |||||