Vulnerabilities (CVE)

Total 396035 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2014-5424 1 Rockwellautomation 1 Connected Components Workbench 2026-06-17 7.5 HIGH N/A
Rockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler.
CVE-2014-5423 1 Carefusion 1 Pyxis Supplystation 2026-06-17 1.9 LOW N/A
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 allows local users to obtain potentially sensitive information by reading a temporary (1) debugging file or (2) developer file.
CVE-2014-5422 1 Carefusion 1 Pyxis Supplystation 2026-06-17 9.7 HIGH N/A
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded service password, which makes it easier for remote attackers to obtain access via unspecified vectors.
CVE-2014-5421 1 Carefusion 1 Pyxis Supplystation 2026-06-17 6.8 MEDIUM N/A
CareFusion Pyxis SupplyStation 8.1 with hardware test tool 1.0.16 and earlier has a hardcoded database password, which makes it easier for local users to gain privileges by leveraging cabinet access.
CVE-2014-5420 1 Carefusion 1 Pyxis Supplystation 2026-06-17 3.5 LOW N/A
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded application password, which makes it easier for remote authenticated users to obtain application-file access via unspecified vectors.
CVE-2014-5419 1 Ge 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more 2026-06-17 10.0 HIGH N/A
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.
CVE-2014-5418 1 Ge 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more 2026-06-17 5.0 MEDIUM N/A
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.
CVE-2014-5417 1 Meinberg 8 Lantime M100, Lantime M200, Lantime M300 and 5 more 2026-06-17 7.5 HIGH N/A
Cross-site scripting (XSS) vulnerability in Meinberg NTP Server firmware on LANTIME M-Series devices 6.15.019 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2014-5415 1 Beckhoff 2 Embedded Pc Images, Twincat 2026-06-17 9.4 HIGH 9.1 CRITICAL
Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components might allow remote attackers to obtain access via the (1) Windows CE Remote Configuration Tool, (2) CE Remote Display service, or (3) TELNET service.
CVE-2014-5414 1 Beckhoff 2 Embedded Pc Images, Twincat 2026-06-17 9.4 HIGH 9.1 CRITICAL
Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components do not restrict the number of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
CVE-2014-5413 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2026-06-17 6.4 MEDIUM N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
CVE-2014-5412 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2026-06-17 6.4 MEDIUM N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
CVE-2014-5411 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2026-06-17 4.9 MEDIUM N/A
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
CVE-2014-5410 1 Rockwellautomation 1 Ab Micrologix Controller 2026-06-17 7.1 HIGH N/A
The DNP3 feature on Rockwell Automation Allen-Bradley MicroLogix 1400 1766-Lxxxxx A FRN controllers 7 and earlier and 1400 1766-Lxxxxx B FRN controllers before 15.001 allows remote attackers to cause a denial of service (process disruption) via malformed packets over (1) an Ethernet network or (2) a serial line.
CVE-2014-5409 1 Ge 1 Hydran M2 2026-06-17 6.4 MEDIUM N/A
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values.
CVE-2014-5408 1 Nordex 1 Nordex Control 2 Scada 2026-06-17 7.5 HIGH N/A
Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.
CVE-2014-5407 1 Schneider-electric 1 Vampset 2026-06-17 4.1 MEDIUM N/A
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
CVE-2014-5406 1 Hospira 3 Lifecare Pca3, Lifecare Pca5, Lifecare Pcainfusion Firmware 2026-06-17 7.6 HIGH N/A
The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.
CVE-2014-5405 1 Hospira 1 Mednet 2026-06-17 9.0 HIGH N/A
Hospira MedNet before 6.1 uses a hardcoded cleartext password to control SQL database authorization, which allows remote authenticated users to bypass intended access restrictions by leveraging knowledge of this password.
CVE-2014-5403 1 Hospira 1 Mednet 2026-06-17 6.8 MEDIUM N/A
Hospira MedNet before 6.1 uses hardcoded cryptographic keys for protection of data transmission from infusion pumps, which allows remote attackers to obtain sensitive information by sniffing the network.