Vulnerabilities (CVE)

Total 398522 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2016-5823 1 Libical Project 1 Libical 2026-06-17 4.3 MEDIUM 5.5 MEDIUM
The icalproperty_new_clone function in libical 0.47 and 1.0 allows remote attackers to cause a denial of service (use-after-free) via a crafted ics file.
CVE-2016-5822 1 Huawei 1 Oceanstor 5800 V3 2026-06-17 7.8 HIGH 7.5 HIGH
Huawei Oceanstor 5800 before V300R002C10SPC100 allows remote attackers to cause a denial of service (CPU consumption) via a large number of crafted HTTP packets.
CVE-2016-5821 1 Huawei 1 Hisuite 2026-06-17 7.2 HIGH 7.8 HIGH
Huawei HiSuite before 4.0.4.204_ove (Out of China) and before 4.0.4.301 (China) use a weak ACL (FILE_WRITE_DATA for BUILTIN\Users) for the HiSuite service directory, which allows local users to gain SYSTEM privileges via a Trojan horse (1) SspiCli.dll or (2) USERENV.dll file or possibly other unspecified DLL files.
CVE-2016-5819 1 Moxa 10 Oncell G3100v2, Oncell G3100v2 Firmware, Oncell G3111 and 7 more 2026-06-17 4.3 MEDIUM 6.1 MEDIUM
Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user’s browser within the trust relationship between their browser and the server.
CVE-2016-5818 1 Schneider-electric 2 Powerlogic Pm8ecc, Powerlogic Pm8ecc Firmware 2026-06-17 7.5 HIGH 9.8 CRITICAL
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
CVE-2016-5817 1 Navis 1 Webaccess 2026-06-17 7.5 HIGH 9.8 CRITICAL
SQL injection vulnerability in news pages in Cargotec Navis WebAccess before 2016-08-10 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
CVE-2016-5816 1 Westermo 8 Mrd-305-din, Mrd-305-din Firmware, Mrd-315-din and 5 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source.
CVE-2016-5815 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2026-06-17 7.5 HIGH 9.8 CRITICAL
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
CVE-2016-5814 1 Rockwellautomation 5 Rslogix 500 Professional Edition, Rslogix 500 Standard Edition, Rslogix 500 Starter Edition and 2 more 2026-06-17 9.3 HIGH 8.6 HIGH
Buffer overflow in Rockwell Automation RSLogix Micro Starter Lite, RSLogix Micro Developer, RSLogix 500 Starter Edition, RSLogix 500 Standard Edition, and RSLogix 500 Professional Edition allows remote attackers to execute arbitrary code via a crafted RSS project file.
CVE-2016-5813 1 Visonic 2 Powerlink2, Powerlink2 Firmware 2026-06-17 5.0 MEDIUM 5.3 MEDIUM
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in the web server (INFORMATION EXPOSURE).
CVE-2016-5812 1 Moxa 7 Oncell G3001 Firmware, Oncell G3100v2, Oncell G3100v2 Firmware and 4 more 2026-06-17 2.1 LOW 3.3 LOW
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file.
CVE-2016-5811 1 Visonic 2 Powerlink2, Powerlink2 Firmware 2026-06-17 4.3 MEDIUM 6.1 MEDIUM
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. User controlled input is not neutralized prior to being placed in web page output (CROSS-SITE SCRIPTING).
CVE-2016-5810 1 Advantech 1 Webaccess 2026-06-17 4.0 MEDIUM 4.9 MEDIUM
upAdminPg.asp in Advantech WebAccess before 8.1_20160519 allows remote authenticated administrators to obtain sensitive password information via unspecified vectors.
CVE-2016-5809 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2026-06-17 6.8 MEDIUM 8.8 HIGH
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
CVE-2016-5807 1 Tollgrade 1 Lighthouse Sms 2026-06-17 5.5 MEDIUM 8.1 HIGH
Tollgrade LightHouse SMS before 5.1 patch 3 allows remote authenticated users to bypass an intended administrative-authentication requirement, and read or change parameter values, via a direct request.
CVE-2016-5805 1 Delta Electronics 3 Ispsoft, Pmsoft, Wplsoft 2026-06-17 6.8 MEDIUM 7.8 HIGH
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to2.10.10. There are multiple instances of heap-based buffer overflows that may allow malicious files to cause the execution of arbitrary code or a denial of service.
CVE-2016-5804 1 Moxa 10 Mgate Mb3170, Mgate Mb3170 Firmware, Mgate Mb3180 and 7 more 2026-06-17 5.0 MEDIUM 9.8 CRITICAL
Moxa MGate MB3180 before 1.8, MGate MB3280 before 2.7, MGate MB3480 before 2.6, MGate MB3170 before 2.5, and MGate MB3270 before 2.7 use weak encryption, which allows remote attackers to bypass authentication via a brute-force series of guesses for a parameter value.
CVE-2016-5803 1 Ca Technologies 1 Unified Infrastructure Management 2026-06-17 7.5 HIGH 8.6 HIGH
An issue was discovered in CA Unified Infrastructure Management Version 8.47 and earlier. The Unified Infrastructure Management software uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize sequences such as ".." that can resolve to a location that is outside of that directory.
CVE-2016-5802 1 Delta Electronics 3 Ispsoft, Pmsoft, Wplsoft 2026-06-17 6.8 MEDIUM 7.8 HIGH
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to 2.10.10. Multiple instances of out-of-bounds write conditions may allow malicious files to be read and executed by the affected software.
CVE-2016-5801 1 Omnimetrix 1 Omniview 2026-06-17 5.0 MEDIUM 7.5 HIGH
An issue was discovered in OmniMetrix OmniView, Version 1.2. Insufficient password requirements for the OmniView web application may allow an attacker to gain access by brute forcing account passwords.