| CVE-2017-6038 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2026-06-17 | 5.8 MEDIUM | 7.1 HIGH |
| A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request. | |||||
| CVE-2017-6037 | 1 We-con | 1 Levi Studio Hmi Editor | 2026-06-17 | 9.3 HIGH | 8.8 HIGH |
| A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system. | |||||
| CVE-2017-6036 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2026-06-17 | 4.3 MEDIUM | 6.5 MEDIUM |
| A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination. | |||||
| CVE-2017-6035 | 1 We-con | 1 Levi Studio Hmi Editor | 2026-06-17 | 9.3 HIGH | 8.8 HIGH |
| A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system. | |||||
| CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | |||||
| CVE-2017-6033 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. | |||||
| CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | |||||
| CVE-2017-6031 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2026-06-17 | 6.8 MEDIUM | 8.8 HIGH |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. | |||||
| CVE-2017-6030 | 1 Schneider-electric | 6 Modicon M221, Modicon M221 Firmware, Modicon M241 and 3 more | 2026-06-17 | 6.4 MEDIUM | 6.5 MEDIUM |
| A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections. | |||||
| CVE-2017-6029 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2026-06-17 | 3.5 LOW | 5.4 MEDIUM |
| A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution. | |||||
| CVE-2017-6028 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2026-06-17 | 5.0 MEDIUM | 9.8 CRITICAL |
| An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application. | |||||
| CVE-2017-6027 | 1 Codesys | 1 Web Server | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution. | |||||
| CVE-2017-6026 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2026-06-17 | 6.4 MEDIUM | 9.1 CRITICAL |
| A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised. | |||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | |||||
| CVE-2017-6024 | 1 Rockwellautomation | 4 Compactlogix 5380, Compactlogix 5380 Firmware, Controllogix 5580 and 1 more | 2026-06-17 | 7.1 HIGH | 5.9 MEDIUM |
| A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller. | |||||
| CVE-2017-6023 | 1 Fatek | 5 Ethernet Module Configuration Tool Cbe Firmware, Ethernet Module Configuration Tool Cbeh Firmware, Ethernet Module Configuration Tool Cm25e Firmware and 2 more | 2026-06-17 | 9.0 HIGH | 9.8 CRITICAL |
| An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device. | |||||
| CVE-2017-6022 | 1 Bd | 2 Kla Journal Service, Performa | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. | |||||
| CVE-2017-6021 | 2 Aveva, Schneider-electric | 2 Clearscada, Clearscada | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | |||||
| CVE-2017-6020 | 1 Lcds | 1 Laquis Scada | 2026-06-17 | 4.0 MEDIUM | 5.3 MEDIUM |
| Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level. | |||||
| CVE-2017-6019 | 1 Schneider-electric | 2 Conext Combox 865-1058, Conext Combox 865-1058 Firmware | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot. | |||||