| CVE-2017-9970 | 1 Schneider-electric | 1 Struxureon Gateway | 2026-06-17 | 9.0 HIGH | 7.2 HIGH |
| A remote code execution vulnerability exists in Schneider Electric's StruxureOn Gateway versions 1.1.3 and prior. Uploading a zip which contains carefully crafted metadata allows for the file to be uploaded to any directory on the host machine information which could lead to remote code execution. | |||||
| CVE-2017-9969 | 1 Schneider-electric | 1 Igss Mobile | 2026-06-17 | 2.1 LOW | 6.7 MEDIUM |
| An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information. | |||||
| CVE-2017-9968 | 1 Schneider-electric | 1 Igss Mobile | 2026-06-17 | 4.3 MEDIUM | 5.9 MEDIUM |
| A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack. | |||||
| CVE-2017-9967 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2026-06-17 | 4.6 MEDIUM | 7.8 HIGH |
| A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security. | |||||
| CVE-2017-9966 | 1 Schneider-electric | 1 Pelco Videoxpert | 2026-06-17 | 7.1 HIGH | 7.1 HIGH |
| A privilege escalation vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. By replacing certain files, an unauthorized user can obtain system privileges and the inserted code would execute at an elevated privilege level. | |||||
| CVE-2017-9965 | 1 Schneider-electric | 1 Pelco Videoxpert | 2026-06-17 | 5.0 MEDIUM | 5.8 MEDIUM |
| An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files. | |||||
| CVE-2017-9964 | 1 Schneider-electric | 1 Pelco Videoxpert | 2026-06-17 | 5.8 MEDIUM | 6.9 MEDIUM |
| A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack. | |||||
| CVE-2017-9963 | 1 Schneider-electric | 1 Powerscada Anywhere | 2026-06-17 | 5.8 MEDIUM | 8.1 HIGH |
| A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack. | |||||
| CVE-2017-9962 | 1 Aveva | 1 Clearscada | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. Client applications affected include ViewX and the Server Icon. | |||||
| CVE-2017-9961 | 1 Schneider-electric | 1 Pro-face Gp Pro Ex | 2026-06-17 | 4.6 MEDIUM | 7.8 HIGH |
| A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process. | |||||
| CVE-2017-9960 | 1 Schneider-electric | 1 U.motion Builder | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error provides more information than should be available to an unauthenticated user. | |||||
| CVE-2017-9959 | 1 Schneider-electric | 1 U.motion Builder | 2026-06-17 | 4.9 MEDIUM | 5.5 MEDIUM |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. | |||||
| CVE-2017-9958 | 1 Schneider-electric | 1 U.motion Builder | 2026-06-17 | 7.2 HIGH | 7.8 HIGH |
| An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the system configuration can allow an attacker to execute arbitrary code under the context of root. | |||||
| CVE-2017-9957 | 1 Schneider-electric | 1 U.motion Builder | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials. | |||||
| CVE-2017-9956 | 1 Schneider-electric | 1 U.motion Builder | 2026-06-17 | 7.5 HIGH | 7.3 HIGH |
| An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass | |||||
| CVE-2017-9955 | 1 Gnu | 1 Binutils | 2026-06-17 | 4.3 MEDIUM | 5.5 MEDIUM |
| The get_build_id function in opncls.c in the Binary File Descriptor (BFD) library (aka libbfd), as distributed in GNU Binutils 2.28, allows remote attackers to cause a denial of service (heap-based buffer over-read and application crash) via a crafted file in which a certain size field is larger than a corresponding data field, as demonstrated by mishandling within the objdump program. | |||||
| CVE-2017-9954 | 1 Gnu | 1 Binutils | 2026-06-17 | 4.3 MEDIUM | 5.5 MEDIUM |
| The getvalue function in tekhex.c in the Binary File Descriptor (BFD) library (aka libbfd), as distributed in GNU Binutils 2.28, allows remote attackers to cause a denial of service (stack-based buffer over-read and application crash) via a crafted tekhex file, as demonstrated by mishandling within the nm program. | |||||
| CVE-2017-9953 | 2 Exiv2, Redhat | 2 Exiv2, Enterprise Linux | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| There is an invalid free in Image::printIFDStructure that leads to a Segmentation fault in Exiv2 0.26. A crafted input will lead to a remote denial of service attack. | |||||
| CVE-2017-9951 | 1 Memcached | 1 Memcached | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| The try_read_command function in memcached.c in memcached before 1.4.39 allows remote attackers to cause a denial of service (segmentation fault) via a request to add/set a key, which makes a comparison between signed and unsigned int and triggers a heap-based buffer over-read. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-8705. | |||||
| CVE-2017-9949 | 1 Radare | 1 Radare2 | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| The grub_memmove function in shlr/grub/kern/misc.c in radare2 1.5.0 allows remote attackers to cause a denial of service (stack-based buffer underflow and application crash) or possibly have unspecified other impact via a crafted binary file, possibly related to a buffer underflow in fs/ext2.c in GNU GRUB 2.02. | |||||