Total
413371 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-14491 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2026-06-17 | 4.0 MEDIUM | 6.5 MEDIUM |
| OpenClinic GA versions 5.09.02 and 5.89.05b do not properly check permissions before executing SQL queries, which may allow a low-privilege user to access privileged information. | |||||
| CVE-2020-14490 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| OpenClinic GA 5.09.02 and 5.89.05b includes arbitrary local files specified within its parameter and executes some files, which may allow disclosure of sensitive files or the execution of malicious uploaded files. | |||||
| CVE-2020-14489 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2026-06-17 | 5.0 MEDIUM | 6.2 MEDIUM |
| OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques. | |||||
| CVE-2020-14488 | 1 Freemedsoftware | 1 Openclinic Ga | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| OpenClinic GA 5.09.02 and 5.89.05b does not properly verify uploaded files, which may allow a low-privilege user to upload and execute arbitrary files on the system. | |||||
| CVE-2020-14487 | 1 Freemedsoftware | 1 Openclinic Ga | 2026-06-17 | 7.5 HIGH | 9.4 CRITICAL |
| OpenClinic GA 5.09.02 contains a hidden default user account that may be accessed if an administrator has not expressly turned off this account, which may allow an attacker to login and execute arbitrary commands. | |||||
| CVE-2020-14486 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| An attacker may bypass permission/authorization checks in OpenClinic GA 5.09.02 and 5.89.05b by ignoring the redirect of a permission failure, which may allow unauthorized execution of commands. | |||||
| CVE-2020-14485 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries. | |||||
| CVE-2020-14484 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2026-06-17 | 5.0 MEDIUM | 9.8 CRITICAL |
| OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass the system’s account lockout protection, which may allow brute force password attacks. | |||||
| CVE-2020-14483 | 1 Tridium | 2 Niagara, Niagara Enterprise Security | 2026-06-17 | 3.3 LOW | 4.3 MEDIUM |
| A timeout during a TLS handshake can result in the connection failing to terminate. This can result in a Niagara thread hanging and requires a manual restart of Niagara (Versions 4.6.96.28, 4.7.109.20, 4.7.110.32, 4.8.0.110) and Niagara Enterprise Security (Versions 2.4.31, 2.4.45, 4.8.0.35) to correct. | |||||
| CVE-2020-14482 | 1 Deltaww | 1 Dopsoft | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Delta Industrial Automation DOPSoft, Version 4.00.08.15 and prior. Opening a specially crafted project file may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. | |||||
| CVE-2020-14481 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | 2.1 LOW | 7.8 HIGH |
| The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE. | |||||
| CVE-2020-14480 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | 2.1 LOW | 5.5 MEDIUM |
| Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials. | |||||
| CVE-2020-14479 | 1 Inductiveautomation | 1 Ignition | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server | |||||
| CVE-2020-14478 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2026-06-17 | 5.6 MEDIUM | 7.1 HIGH |
| A local, authenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service condition and allow the attacker to arbitrarily read any local file via system-level services. | |||||
| CVE-2020-14477 | 1 Philips | 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more | 2026-06-17 | 3.6 LOW | 3.6 LOW |
| In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information. | |||||
| CVE-2020-14475 | 1 Dolibarr | 1 Dolibarr Erp\/crm | 2026-06-17 | 4.3 MEDIUM | 6.1 MEDIUM |
| A reflected cross-site scripting (XSS) vulnerability in Dolibarr 11.0.3 allows remote attackers to inject arbitrary web script or HTML into public/notice.php (related to transphrase and transkey). | |||||
| CVE-2020-14474 | 1 Cellebrite | 2 Ufed, Ufed Firmware | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| The Cellebrite UFED physical device 5.0 through 7.5.0.845 relies on key material hardcoded within both the executable code supporting the decryption process, and within the encrypted files themselves by using a key enveloping technique. The recovered key material is the same for every device running the same version of the software, and does not appear to be changed with each new build. It is possible to reconstruct the decryption process using the hardcoded key material and obtain easy access to otherwise protected data. | |||||
| CVE-2020-14473 | 1 Draytek | 6 Vigor2960, Vigor2960 Firmware, Vigor300b and 3 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| Stack-based buffer overflow vulnerability in Vigor3900, Vigor2960, and Vigor300B with firmware before 1.5.1.1. | |||||
| CVE-2020-14472 | 1 Draytek | 6 Vigor2960, Vigor2960 Firmware, Vigor300b and 3 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| On Draytek Vigor3900, Vigor2960, and Vigor 300B devices before 1.5.1.1, there are some command-injection vulnerabilities in the mainfunction.cgi file. | |||||
| CVE-2020-14470 | 1 Octopus | 1 Octopus Deploy | 2026-06-17 | 4.0 MEDIUM | 6.5 MEDIUM |
| In Octopus Deploy 2018.8.0 through 2019.x before 2019.12.2, an authenticated user with could trigger a deployment that leaks the Helm Chart repository password. | |||||
