| CVE-2020-25196 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2026-06-17 | 5.0 MEDIUM | 9.8 CRITICAL |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication. | |||||
| CVE-2020-25195 | 1 Hosteng | 6 H0-ecom100, H0-ecom100 Firmware, H2-ecom100 and 3 more | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device. | |||||
| CVE-2020-25194 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges. | |||||
| CVE-2020-25193 | 1 Ge | 6 Rt430, Rt430 Firmware, Rt431 and 3 more | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. | |||||
| CVE-2020-25192 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization. | |||||
| CVE-2020-25191 | 1 Ni | 2 Compactrio, Compactrio Firmware | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely. | |||||
| CVE-2020-25190 | 1 Moxa | 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext. | |||||
| CVE-2020-25189 | 1 Paradox | 2 Ip150, Ip150 Firmware | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09). | |||||
| CVE-2020-25188 | 1 Laquisscada | 1 Scada | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability on the LAquis SCADA (Versions prior to 4.3.1.870). | |||||
| CVE-2020-25187 | 1 Medtronic | 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware | 2026-06-17 | 10.0 HIGH | 8.8 HIGH |
| Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device | |||||
| CVE-2020-25186 | 1 We-con | 1 Levistudiou | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| An XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file disclosure. | |||||
| CVE-2020-25185 | 1 Paradox | 2 Ip150, Ip150 Firmware | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| The affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09). | |||||
| CVE-2020-25184 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2026-06-17 | 2.1 LOW | 7.8 HIGH |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure. | |||||
| CVE-2020-25183 | 1 Medtronic | 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware | 2026-06-17 | 5.8 MEDIUM | 8.0 HIGH |
| Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication. | |||||
| CVE-2020-25182 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2026-06-17 | 4.6 MEDIUM | 6.7 MEDIUM |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems. | |||||
| CVE-2020-25181 | 1 We-con | 1 Plc Editor | 2026-06-17 | 6.8 MEDIUM | 8.8 HIGH |
| WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution. | |||||
| CVE-2020-25180 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2026-06-17 | 4.3 MEDIUM | 5.3 MEDIUM |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. | |||||
| CVE-2020-25179 | 1 Gehealthcare | 224 1.5t Brivo Mr355, 1.5t Brivo Mr355 Firmware, 3.0t Signa Hd 16 and 221 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network. | |||||
| CVE-2020-25178 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2026-06-17 | 9.3 HIGH | 7.5 HIGH |
| ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files. | |||||
| CVE-2020-25177 | 1 We-con | 1 Plc Editor | 2026-06-17 | 6.8 MEDIUM | 8.8 HIGH |
| WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution. | |||||