| CVE-2021-31889 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2026-06-17 | 6.4 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015) | |||||
| CVE-2021-31888 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018) | |||||
| CVE-2021-31887 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016) | |||||
| CVE-2021-31886 | 1 Siemens | 41 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 38 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010) | |||||
| CVE-2021-31885 | 1 Siemens | 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009) | |||||
| CVE-2021-31884 | 1 Siemens | 42 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 39 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014) | |||||
| CVE-2021-31883 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2026-06-17 | 5.0 MEDIUM | 7.1 HIGH |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013) | |||||
| CVE-2021-31882 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2026-06-17 | 5.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011) | |||||
| CVE-2021-31881 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2026-06-17 | 5.0 MEDIUM | 7.1 HIGH |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008) | |||||
| CVE-2021-31878 | 1 Digium | 1 Asterisk | 2026-06-17 | 4.0 MEDIUM | 6.5 MEDIUM |
| An issue was discovered in PJSIP in Asterisk before 16.19.1 and before 18.5.1. To exploit, a re-INVITE without SDP must be received after Asterisk has sent a BYE request. | |||||
| CVE-2021-31876 | 1 Bitcoin | 1 Bitcoin | 2026-06-17 | 6.4 MEDIUM | 6.5 MEDIUM |
| Bitcoin Core 0.12.0 through 0.21.1 does not properly implement the replacement policy specified in BIP125, which makes it easier for attackers to trigger a loss of funds, or a denial of service attack against downstream projects such as Lightning network nodes. An unconfirmed child transaction with nSequence = 0xff_ff_ff_ff, spending an unconfirmed parent with nSequence <= 0xff_ff_ff_fd, should be replaceable because there is inherited signaling by the child transaction. However, the actual PreChecks implementation does not enforce this. Instead, mempool rejects the replacement attempt of the unconfirmed child transaction. | |||||
| CVE-2021-31875 | 1 Cesanta | 1 Mongooseos Mjs | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| In mjs_json.c in Cesanta MongooseOS mJS 1.26, a maliciously formed JSON string can trigger an off-by-one heap-based buffer overflow in mjs_json_parse, which can potentially lead to redirection of control flow. NOTE: the original reporter disputes the significance of this finding because "there isn’t very much of an opportunity to exploit this reliably for an information leak, so there isn’t any real security impact." | |||||
| CVE-2021-31874 | 1 Zohocorp | 1 Manageengine Adselfservice Plus | 2026-06-17 | 4.3 MEDIUM | 5.9 MEDIUM |
| Zoho ManageEngine ADSelfService Plus before 6104, in rare situations, allows attackers to obtain sensitive information about the password-sync database application. | |||||
| CVE-2021-31873 | 2 Debian, Klibc Project | 2 Debian Linux, Klibc | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in klibc before 2.0.9. Additions in the malloc() function may result in an integer overflow and a subsequent heap buffer overflow. | |||||
| CVE-2021-31872 | 2 Debian, Klibc Project | 2 Debian Linux, Klibc | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in klibc before 2.0.9. Multiple possible integer overflows in the cpio command on 32-bit systems may result in a buffer overflow or other security impact. | |||||
| CVE-2021-31871 | 2 Debian, Klibc Project | 2 Debian Linux, Klibc | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| An issue was discovered in klibc before 2.0.9. An integer overflow in the cpio command may result in a NULL pointer dereference on 64-bit systems. | |||||
| CVE-2021-31870 | 2 Debian, Klibc Project | 2 Debian Linux, Klibc | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in klibc before 2.0.9. Multiplication in the calloc() function may result in an integer overflow and a subsequent heap buffer overflow. | |||||
| CVE-2021-31869 | 1 Pimcore | 1 Pimcore | 2026-06-17 | 5.0 MEDIUM | 6.5 MEDIUM |
| Pimcore AdminBundle version 6.8.0 and earlier suffers from a SQL injection issue in the specificID variable used by the application. This issue was fixed in version 6.9.4 of the product. | |||||
| CVE-2021-31868 | 1 Rapid7 | 1 Nexpose | 2026-06-17 | 5.5 MEDIUM | 4.3 MEDIUM |
| Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021. | |||||
| CVE-2021-31867 | 1 Pimcore | 1 Customer Management Framework | 2026-06-17 | 5.0 MEDIUM | 6.5 MEDIUM |
| Pimcore Customer Data Framework version 3.0.0 and earlier suffers from a Boolean-based blind SQL injection issue in the $id parameter of the SegmentAssignmentController.php component of the application. This issue was fixed in version 3.0.2 of the product. | |||||