Total
420475 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-31910 | 1 Jetbrains | 1 Teamcity | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| In JetBrains TeamCity before 2020.2.3, information disclosure via SSRF was possible. | |||||
| CVE-2021-31909 | 1 Jetbrains | 1 Teamcity | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| In JetBrains TeamCity before 2020.2.3, argument injection leading to remote code execution was possible. | |||||
| CVE-2021-31908 | 1 Jetbrains | 1 Teamcity | 2026-06-17 | 3.5 LOW | 5.4 MEDIUM |
| In JetBrains TeamCity before 2020.2.3, stored XSS was possible on several pages. | |||||
| CVE-2021-31907 | 1 Jetbrains | 1 Teamcity | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| In JetBrains TeamCity before 2020.2.2, permission checks for changing TeamCity plugins were implemented improperly. | |||||
| CVE-2021-31906 | 1 Jetbrains | 1 Teamcity | 2026-06-17 | 4.0 MEDIUM | 2.7 LOW |
| In JetBrains TeamCity before 2020.2.2, audit logs were not sufficient when an administrator uploaded a file. | |||||
| CVE-2021-31905 | 1 Jetbrains | 1 Youtrack | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| In JetBrains YouTrack before 2020.6.8801, information disclosure in an issue preview was possible. | |||||
| CVE-2021-31904 | 1 Jetbrains | 1 Teamcity | 2026-06-17 | 4.3 MEDIUM | 6.1 MEDIUM |
| In JetBrains TeamCity before 2020.2.2, XSS was potentially possible on the test history page. | |||||
| CVE-2021-31903 | 1 Jetbrains | 1 Youtrack | 2026-06-17 | 4.3 MEDIUM | 6.1 MEDIUM |
| In JetBrains YouTrack before 2021.1.9819, a pull request's title was sanitized insufficiently, leading to XSS. | |||||
| CVE-2021-31902 | 1 Jetbrains | 1 Youtrack | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| In JetBrains YouTrack before 2020.6.6600, access control during the exporting of issues was implemented improperly. | |||||
| CVE-2021-31901 | 1 Jetbrains | 1 Hub | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| In JetBrains Hub before 2021.1.13079, two-factor authentication wasn't enabled properly for the All Users group. | |||||
| CVE-2021-31900 | 1 Jetbrains | 1 Code With Me | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| In JetBrains Code With Me bundled to the compatible IDE versions before 2021.1, a client could open a browser on a host. | |||||
| CVE-2021-31899 | 1 Jetbrains | 1 Code With Me | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| In JetBrains Code With Me bundled to the compatible IDEs before version 2021.1, the client could execute code in read-only mode. | |||||
| CVE-2021-31898 | 1 Jetbrains | 1 Webstorm | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| In JetBrains WebStorm before 2021.1, HTTP requests were used instead of HTTPS. | |||||
| CVE-2021-31897 | 1 Jetbrains | 1 Webstorm | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| In JetBrains WebStorm before 2021.1, code execution without user confirmation was possible for untrusted projects. | |||||
| CVE-2021-31895 | 1 Siemens | 104 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 101 more | 2026-06-17 | 7.5 HIGH | 8.1 HIGH |
| A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution. | |||||
| CVE-2021-31894 | 1 Siemens | 8 Simatic Pcs 7, Simatic Pcs 7 Firmware, Simatic Pdm and 5 more | 2026-06-17 | 7.2 HIGH | 8.8 HIGH |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software. | |||||
| CVE-2021-31893 | 1 Siemens | 8 Simatic Pcs, Simatic Pcs Firmware, Simatic Pdm and 5 more | 2026-06-17 | 7.2 HIGH | 7.8 HIGH |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution. | |||||
| CVE-2021-31892 | 1 Siemens | 20 Sinumerik Analyse Mycondition, Sinumerik Analyse Mycondition Firmware, Sinumerik Analyze Myperformance and 17 more | 2026-06-17 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario. | |||||
| CVE-2021-31891 | 2 Debian, Siemens | 6 Debian Linux, Desigo Cc, Gma-manager and 3 more | 2026-06-17 | 10.0 HIGH | 10.0 CRITICAL |
| A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges. | |||||
| CVE-2021-31890 | 1 Siemens | 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more | 2026-06-17 | 6.4 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017) | |||||