Vulnerabilities (CVE)

Filtered by CWE-787
Total 14871 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-2703 1 Tenda 2 Ac10u, Ac10u Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2616 1 Mozilla 2 Firefox, Thunderbird 2026-06-17 N/A 2.7 LOW
To harden ICU against exploitation, the behavior for out-of-memory conditions was changed to crash instead of attempt to continue. This vulnerability affects Firefox ESR < 115.9 and Thunderbird < 115.9.
CVE-2024-2615 1 Mozilla 1 Firefox 2026-06-17 N/A 9.8 CRITICAL
Memory safety bugs present in Firefox 123. Some of these bugs showed evidence of memory corruption and we presume that with enough effort some of these could have been exploited to run arbitrary code. This vulnerability affects Firefox < 124.
CVE-2024-2614 2 Debian, Mozilla 3 Debian Linux, Firefox, Thunderbird 2026-06-17 N/A 8.8 HIGH
Memory safety bugs present in Firefox 123, Firefox ESR 115.8, and Thunderbird 115.8. Some of these bugs showed evidence of memory corruption and we presume that with enough effort some of these could have been exploited to run arbitrary code. This vulnerability affects Firefox < 124, Firefox ESR < 115.9, and Thunderbird < 115.9.
CVE-2024-2581 1 Tenda 2 Ac10, Ac10 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
CVE-2024-2558 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2547 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2546 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2490 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2489 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2488 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2487 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2486 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
CVE-2024-2485 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2212 1 Eclipse 1 Threadx 2026-06-17 N/A 7.3 HIGH
In Eclipse ThreadX before 6.4.0, xQueueCreate() and xQueueCreateSet() functions from the FreeRTOS compatibility API (utility/rtos_compatibility_layers/FreeRTOS/tx_freertos.c) were missing parameter checks. This could lead to integer wraparound, under-allocations and heap buffer overflows.
CVE-2024-2184 2026-06-17 N/A 9.8 CRITICAL
Buffer overflow in identifier field of WSD probe request process of Small Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger the affected product being unresponsive or to execute arbitrary code.*:Satera MF740C Series/Satera MF640C Series/Satera LBP660C Series/Satera LBP620C Series firmware v12.07 and earlier, and Satera MF750C Series/Satera LBP670C Series firmware v03.09 and earlier sold in Japan.Color imageCLASS MF740C Series/Color imageCLASS MF640C Series/Color imageCLASS X MF1127C/Color imageCLASS LBP664Cdw/Color imageCLASS LBP622Cdw/Color imageCLASS X LBP1127C firmware v12.07 and earlier, and Color imageCLASS MF750C Series/Color imageCLASS X MF1333C/Color imageCLASS LBP674Cdw/Color imageCLASS X LBP1333C firmware v03.09 and earlier sold in US.i-SENSYS MF740C Series/i-SENSYS MF640C Series/C1127i Series/i-SENSYS LBP660C Series/i-SENSYS LBP620C Series/C1127P firmware v12.07 and earlier, and i-SENSYS MF750C Series/C1333i Series/i-SENSYS LBP673Cdw/C1333P firmware v03.09 and earlier sold in Europe.
CVE-2024-2174 2 Fedoraproject, Google 2 Fedora, Chrome 2026-06-17 N/A 8.8 HIGH
Inappropriate implementation in V8 in Google Chrome prior to 122.0.6261.111 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: High)
CVE-2024-2173 2 Fedoraproject, Google 2 Fedora, Chrome 2026-06-17 N/A 8.8 HIGH
Out of bounds memory access in V8 in Google Chrome prior to 122.0.6261.111 allowed a remote attacker to perform out of bounds memory access via a crafted HTML page. (Chromium security severity: High)
CVE-2024-2011 1 Hitachienergy 2 Foxman-un, Unem 2026-06-17 N/A 8.6 HIGH
A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can be used to execute arbitrary code, which is usually outside the scope of a program's implicit security policy
CVE-2024-29943 1 Mozilla 1 Firefox 2026-06-17 N/A 9.8 CRITICAL
An attacker was able to perform an out-of-bounds read or write on a JavaScript object by fooling range-based bounds check elimination. This vulnerability affects Firefox < 124.0.1.