Total
6742 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2026-48362 | 1 Adobe | 1 Coldfusion | 2026-08-28 | N/A | 10.0 CRITICAL |
| ColdFusion is affected by an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability that could result in arbitrary code execution in the context of the current user. An attacker could exploit this vulnerability to execute arbitrary code. Exploitation of this issue does not require user interaction. Scope is changed. | |||||
| CVE-2026-48347 | 3 Adobe, Apple, Microsoft | 3 Animate, Macos, Windows | 2026-08-28 | N/A | 7.7 HIGH |
| Animate is affected by an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file. Scope is changed. | |||||
| CVE-2026-48345 | 3 Adobe, Apple, Microsoft | 3 Animate, Macos, Windows | 2026-08-28 | N/A | 8.2 HIGH |
| Animate is affected by an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file. Scope is changed. | |||||
| CVE-2026-21267 | 3 Adobe, Apple, Microsoft | 3 Dreamweaver, Macos, Windows | 2026-08-28 | N/A | 8.6 HIGH |
| Dreamweaver Desktop versions 21.6 and earlier are affected by an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability that could lead in arbitrary code execution by an attacker. Exploitation of this issue requires user interaction in that a victim must open a malicious file and scope is changed. | |||||
| CVE-2026-79623 | 2026-08-27 | 6.5 MEDIUM | 6.3 MEDIUM | ||
| A security vulnerability has been detected in FishCodeTech Muteki up to 0.2.5. The affected element is an unknown function of the file .claude/settings.json of the component Default Local Worker Backend. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The issue was closed with the comment (translated from Chinese): "The project will be refactored and shut down." | |||||
| CVE-2026-74233 | 2026-08-27 | N/A | 9.8 CRITICAL | ||
| Zbtlink WE1326, WE357, WE5926, WE5926-WD, WE826-Q, WE826-T2, WE826-WD, WG108, and WG3526 firmware 19.1101, Zbtlink WE2426-C firmware 19.1112, Zbtlink WE5926-EC_QP firmware 20.0516, Zbtlink WF3526-P firmware 19.051, CTN720-W1, LF-1541, and MT7620N firmware 19.1101, and WRC1 firmware 20.0622 contain an unauthenticated command injection in the infosrvd service (UDP/9992). A remote unauthenticated attacker can send a crafted UDP packet to execute arbitrary commands as root. The service's authentication uses a hardcoded salt and an all-zero wildcard MAC bypass, rendering it ineffective. | |||||
| CVE-2026-71931 | 2026-08-27 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the tftp_upgrade function. The vulnerability is caused by insufficient filtering before the filename field is concatenated into a command. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-71926 | 2026-08-27 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevice function. The vulnerability is caused by insufficient sanitization of the username, password, and location fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-71921 | 2026-08-27 | N/A | 9.8 CRITICAL | ||
| Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. | |||||
| CVE-2026-71916 | 2026-08-27 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the commandTable function. The vulnerability is caused by incomplete filtering of dangerous characters such as backticks, newline characters, and single quotes in the parameter field. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-71472 | 2026-08-27 | N/A | 9.1 CRITICAL | ||
| A flaw was found in acm-search-v2-rhel9. This vulnerability allows an authenticated attacker, such as a hub administrator or a Search Custom Resource (CR) editor, to inject malicious shell commands or SQL statements. This occurs because the WORK_MEM string provided in the Search CR is not properly validated before being used in a bash script and an SQL query. Successful exploitation could lead to arbitrary code execution within the privileged postgres pod, potentially compromising the system. | |||||
| CVE-2026-50112 | 1 Apache | 1 Cloudstack | 2026-08-27 | N/A | 8.8 HIGH |
| SSRF via Metalink Mirror URL Resolution: An authenticated tenant can register a template pointing to an attacker-controlled metalink file containing internal targets. The Secondary Storage VM will retrieve the data and persist it as a template file, which can later be downloaded through normal APIs. RCE on KVM hypervisor via NFS, Metalink files with/without Direct Downloads: An authenticated CloudStack tenant holding the default User role can execute arbitrary shell commands as root on the KVM hypervisor host that runs other tenants' VMs. This is cross-tenant root on the underlying compute, reachable via the public CloudStack API. When a User registers a VM template with directDownload=true and a URL pointing to a .metalink file, the management server fetches the metalink XML and dispatches download to the KVM agent. Inner URLs inside the metalink XML are never re-validated against the scheme allowlist. These issues affect Apache CloudStack: from 4.14.0.0 through 4.20.3.0 and from 4.21.0.0 through 4.22.1.0. Users are recommended to upgrade to version 4.20.3.1 or 4.22.1.1 or later, which fixes the issue. | |||||
| CVE-2026-47359 | 1 Apache | 1 Cloudstack | 2026-08-27 | N/A | 8.8 HIGH |
| Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Apache CloudStack's NAS backup provider plugin. The addBackupRepository API (available since 4.20.0.0) and updateBackupRepository API (introduced in 4.22.0.0) accept unsanitized command options for the backup repository. A malicious operator account can exploit this to inject arbitrary commands that execute on the KVM hypervisor host when any account subsequently performs a backup restore. This issue affects Apache CloudStack: from 4.20.0.0 through 4.20.3.0 and from 4.21.0.0 through 4.22.1.0. Users are recommended to upgrade to version 4.20.3.1 or 4.22.1.1 or later, which fixes the issue. | |||||
| CVE-2026-71906 | 2026-08-26 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorAP models contain a command injection vulnerability in the setLan function. The vulnerability is caused by insufficient validation of the lanIp and lanNetmask fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-58236 | 2026-08-26 | N/A | 5.5 MEDIUM | ||
| SAP NetWeaver Application Server ABAP and ABAP Platform allow an attacker with high privileges to bypass missing security controls on an internal code path leading to operating system command execution. Successful exploitation could allow the attacker to execute OS-level commands that write to the operating system or stop the SAP system, resulting in no impact on confidentiality, low impact on integrity, and high impact on availability. | |||||
| CVE-2026-41451 | 2026-08-26 | N/A | 7.8 HIGH | ||
| UAC (Unix-like Artifacts Collector) versions prior to 3.3.0 contain a command injection vulnerability in the user substitution logic within parse_artifact.sh where usernames and home directories from /etc/passwd are substituted directly into command strings without escaping before execution via eval. Attackers can inject shell metacharacters such as command substitution syntax or semicolons through crafted usernames or home directory paths in /etc/passwd entries to execute arbitrary commands on the analyst's host system. | |||||
| CVE-2026-71905 | 2026-08-26 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorAP models contain a command injection vulnerability in the ExportSettings function. The vulnerability is caused by insufficient filtering of the backupkey, backuptype, and realtime fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-71943 | 2026-08-26 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevNet function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-71928 | 2026-08-26 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the fdftDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||
| CVE-2026-71923 | 2026-08-26 | N/A | 7.2 HIGH | ||
| Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the auth_set function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface. | |||||