Total
3997 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-26627 | 1 Microsoft | 1 Azure Arc | 2026-06-17 | N/A | 7.0 HIGH |
| Improper neutralization of special elements used in a command ('command injection') in Azure Arc allows an authorized attacker to elevate privileges locally. | |||||
| CVE-2025-26385 | 2026-06-17 | N/A | N/A | ||
| Johnson Controls Metasys component listed below have Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution This issue affects * Metasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation, * Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation, * LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1, * System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior, * Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior. | |||||
| CVE-2025-26331 | 1 Dell | 12 Latitude 3420, Latitude 3440, Latitude 5440 and 9 more | 2026-06-17 | N/A | 7.8 HIGH |
| Dell ThinOS 2411 and prior, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution. | |||||
| CVE-2025-26262 | 2026-06-17 | N/A | 6.5 MEDIUM | ||
| An issue in the component /internals/functions of R-fx Networks Linux Malware Detect v1.6.5 allows attackers to escalate privileges and execute arbitrary code via supplying a file that contains a crafted filename. | |||||
| CVE-2025-26063 | 1 Intelbras | 4 Rx 1500, Rx 1500 Firmware, Rx 3000 and 1 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network. | |||||
| CVE-2025-26056 | 2026-06-17 | N/A | 5.4 MEDIUM | ||
| A command injection vulnerability exists in the Infinxt iEdge 100 2.1.32 in the Troubleshoot module "MTR" functionality. The vulnerability is due to improper validation of user-supplied input in the mtrIp parameter. An attacker can exploit this flaw to execute arbitrary operating system commands on the underlying system with the same privileges as the web application process. | |||||
| CVE-2025-25768 | 1 Mrcms | 1 Mrcms | 2026-06-17 | N/A | 5.4 MEDIUM |
| MRCMS v3.1.2 was discovered to contain a server-side template injection (SSTI) vulnerability in the component \servlet\DispatcherServlet.java. This vulnerability allows attackers to execute arbitrary code via a crafted payload. | |||||
| CVE-2025-25766 | 1 Mrcms | 1 Mrcms | 2026-06-17 | N/A | 4.8 MEDIUM |
| An arbitrary file upload vulnerability in the component /file/savefile.do of MRCMS v3.1.2 allows attackers to execute arbitrary code via uploading a crafted .jsp file. | |||||
| CVE-2025-25743 | 1 Dlink | 2 Dir-853, Dir-853 Firmware | 2026-06-17 | N/A | 7.2 HIGH |
| D-Link DIR-853 A1 FW1.20B07 was discovered to contain a command injection vulnerability in the SetVirtualServerSettings module. | |||||
| CVE-2025-25675 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution. | |||||
| CVE-2025-25632 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. | |||||
| CVE-2025-25605 | 1 Totolink | 2 X5000r, X5000r Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| Totolink X5000R V9.1.0u.6369_B20230113 is vulnerable to command injection via the apcli_wps_gen_pincode function in mtkwifi.lua. | |||||
| CVE-2025-25604 | 1 Totolink | 2 X5000r, X5000r Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| Totolink X5000R V9.1.0u.6369_B20230113 is vulnerable to command injection via the vif_disable function in mtkwifi.lua. | |||||
| CVE-2025-25364 | 1 Connectify | 1 Speedify | 2026-06-17 | N/A | 8.4 HIGH |
| A command injection vulnerability in the me.connectify.SMJobBlessHelper XPC service of Speedify VPN up to v15.0.0 allows attackers to execute arbitrary commands with root-level privileges. | |||||
| CVE-2025-25274 | 1 Mattermost | 1 Mattermost Server | 2026-06-17 | N/A | 4.3 MEDIUM |
| Mattermost versions 10.4.x <= 10.4.2, 10.3.x <= 10.3.3, 9.11.x <= 9.11.8 fail to restrict command execution in archived channels, which allows authenticated users to run commands in archived channels. | |||||
| CVE-2025-24861 | 1 Outbackpower | 2 Mojave Inverter Oghi8048a, Mojave Inverter Oghi8048a Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| An attacker may inject commands via specially-crafted post requests. | |||||
| CVE-2025-24333 | 2026-06-17 | N/A | 6.4 MEDIUM | ||
| Nokia Single RAN baseband software earlier than 24R1-SR 1.0 MP contains administrative shell input validation fault, which authenticated admin user can, in theory, potentially use for injecting arbitrary commands for unprivileged baseband OAM service process execution via special characters added to baseband internal COMA_config.xml file. This issue has been corrected starting from release 24R1-SR 1.0 MP and later, by adding proper input validation to OAM service process which prevents injecting special characters via baseband internal COMA_config.xml file. | |||||
| CVE-2025-24285 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| Multiple Improper Input Validation vulnerabilities in UniFi Connect EV Station Lite may allow a Command Injection by a malicious actor with network access to the UniFi Connect EV Station Lite. Affected Products: UniFi Connect EV Station Lite (Version 1.5.1 and earlier) Mitigation: Update UniFi Connect EV Station Lite to Version 1.5.2 or later | |||||
| CVE-2025-24150 | 1 Apple | 4 Ipados, Iphone Os, Macos and 1 more | 2026-06-17 | N/A | 8.8 HIGH |
| A privacy issue was addressed with improved handling of files. This issue is fixed in Safari 18.3, iOS 18.3 and iPadOS 18.3, macOS Sequoia 15.3. Copying a URL from Web Inspector may lead to command injection. | |||||
| CVE-2025-24049 | 1 Microsoft | 1 Azure Command-line Interface | 2026-06-17 | N/A | 8.4 HIGH |
| Improper neutralization of special elements used in a command ('command injection') in Azure Command Line Integration (CLI) allows an unauthorized attacker to elevate privileges locally. | |||||
