Total
11 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-14601 | 2026-08-31 | N/A | N/A | ||
| An OS command injection vulnerability in vsDesk allows an authenticated attacker with administrative privileges to execute arbitrary operating system commands due to insufficient input filtering. An attacker can exploit this flaw to disrupt web server operations, expose sensitive data, or potentially achieve full server compromise. Apply patch from vendor https://vsdesk.ru/ . Versions 14.0101 and on have the patch. | |||||
| CVE-2026-14501 | 1 Ibm | 2 Agentics, Db2 Genius Hub | 2026-08-11 | N/A | 4.3 MEDIUM |
| IBM Db2 Genius Hub 1.1, 1.1.1, 1.1.2 and IBM Agentics 1.0 could allow an attacker to execute arbitrary code or obtain sensitive information due to the use of dangerous functions without sufficient restrictions. | |||||
| CVE-2026-48696 | 1 Pavel-odintsov | 1 Fastnetmon | 2026-07-24 | N/A | 6.2 MEDIUM |
| FastNetMon Community Edition through 1.2.9 has a buffer overflow, a different vulnerability than CVE-2026-48686 and CVE-2026-48689. | |||||
| CVE-2026-54499 | 1 Stanford | 1 Stanza | 2026-07-13 | N/A | 7.5 HIGH |
| Stanza is a Stanford NLP Python library for tokenization, sentence segmentation, NER, and parsing of many human languages. Prior to 1.12.2, Stanza model loaders such as stanza.models.common.pretrain.Pretrain.load() attempt torch.load(..., weights_only=True) but fall back to torch.load(..., weights_only=False) on attacker-controllable pickle.UnpicklingError, allowing a malicious .pt pretrain or model file to execute arbitrary pickle code when a Stanza NLP pipeline loads it. This issue is fixed in version 1.12.2. | |||||
| CVE-2025-67604 | 1 Fortinet | 2 Fortianalyzer, Fortimanager | 2026-06-17 | N/A | 5.3 MEDIUM |
| A use of potentially dangerous function vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.8, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer 6.4 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.8, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager 6.4 all versions may allow an authenticated attacker to cause a system hang via multiple specially crafted HTTP requests causing crashes. This happens if internal locks are aligned, which is out of control of the attacker. | |||||
| CVE-2025-65117 | 1 Aveva | 1 Process Optimization | 2026-06-17 | N/A | 7.4 HIGH |
| The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Designer User) to embed OLE objects into graphics, and escalate their privileges to the identity of a victim user who subsequently interacts with the graphical elements. | |||||
| CVE-2024-50307 | 2026-06-17 | N/A | 5.5 MEDIUM | ||
| Use of potentially dangerous function issue exists in Chatwork Desktop Application (Windows) versions prior to 2.9.2. If a user clicks a specially crafted link in the application, an arbitrary file may be downloaded from an external website and executed. As a result, arbitrary code may be executed on the device that runs Chatwork Desktop Application (Windows). | |||||
| CVE-2024-38434 | 2026-06-17 | N/A | 6.5 MEDIUM | ||
| Unitronics Vision PLC – CWE-676: Use of Potentially Dangerous Function may allow security feature bypass | |||||
| CVE-2024-37387 | 2026-06-17 | N/A | 4.0 MEDIUM | ||
| Use of potentially dangerous function issue exists in Ricoh Streamline NX PC Client. If this vulnerability is exploited, files in the PC where the product is installed may be altered. | |||||
| CVE-2022-39063 | 1 Open5gs | 1 Open5gs | 2026-06-17 | N/A | 7.5 HIGH |
| When Open5GS UPF receives a PFCP Session Establishment Request, it stores related values for building the PFCP Session Establishment Response. Once UPF receives a request, it gets the f_teid_len from incoming message, and then uses it to copy data from incoming message to struct f_teid without checking the maximum length. If the pdi.local_f_teid.len exceeds the maximum length of the struct of f_teid, the memcpy() overwrites the fields (e.g., f_teid_len) after f_teid in the pdr struct. After parsing the request, the UPF starts to build a response. The f_teid_len with its overwritten value is used as a length for memcpy(). A segmentation fault occurs, as a result of a memcpy(), if this overwritten value is large enough. | |||||
| CVE-2021-27474 | 1 Rockwellautomation | 1 Factorytalk Assetcentre | 2026-06-17 | 5.0 MEDIUM | 10.0 CRITICAL |
| Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre. | |||||
