Total
3268 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2018-25140 | 2026-06-17 | N/A | 7.5 HIGH | ||
| FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication. | |||||
| CVE-2018-25139 | 1 Flir | 2 Flir Ax8, Flir Ax8 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| FLIR AX8 Thermal Camera 1.32.16 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly connect to the RTSP stream using tools like VLC or FFmpeg to view and record thermal camera footage. | |||||
| CVE-2018-25137 | 2026-06-17 | N/A | 7.5 HIGH | ||
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability in the ExportConfig REST API that allows attackers to download sensitive configuration files. Attackers can exploit the getConfigExportFile.cgi endpoint to retrieve system configurations, potentially enabling authentication bypass and privilege escalation. | |||||
| CVE-2018-25136 | 2026-06-17 | N/A | 7.5 HIGH | ||
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can retrieve video stream images by directly accessing multiple image endpoints like middleImage.jpg, rightimage.jpg, and leftimage.jpg. | |||||
| CVE-2018-25134 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. | |||||
| CVE-2018-21132 | 1 Netgear | 4 Wac505, Wac505 Firmware, Wac510 and 1 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| Certain NETGEAR devices are affected by authentication bypass. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17. | |||||
| CVE-2018-21041 | 1 Google | 1 Android | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| An issue was discovered on Samsung mobile devices with O(8.x) software. Access to Gallery in the Secure Folder can occur without authentication. The Samsung ID is SVE-2018-13057 (December 2018). | |||||
| CVE-2018-20507 | 1 Gitlab | 1 Gitlab | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| An issue was discovered in GitLab Enterprise Edition 11.2.x through 11.4.x before 11.4.13, 11.5.x before 11.5.6, and 11.6.x before 11.6.1. It has Incorrect Access Control. | |||||
| CVE-2018-20220 | 1 Teracue | 6 Enc-400 Hdmi, Enc-400 Hdmi2, Enc-400 Hdmi2 Firmware and 3 more | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. While the web interface requires authentication before it can be interacted with, a large portion of the HTTP endpoints are missing authentication. An attacker is able to view these pages before being authenticated, and some of these pages may disclose sensitive information. | |||||
| CVE-2018-1757 | 1 Ibm | 1 Security Identity Governance And Intelligence | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| IBM Security Identity Governance and Intelligence 5.2.3.2 and 5.2.4 could allow an attacker to obtain sensitive information due to missing authentication in IGI for the survey application. IBM X-Force ID: 148601. | |||||
| CVE-2018-1745 | 1 Ibm | 1 Security Key Lifecycle Manager | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| IBM Security Key Lifecycle Manager 2.7 and 3.0 could allow an unauthenticated user to restart the SKLM server due to missing authentication. IBM X-Force ID: 148424. | |||||
| CVE-2018-1501 | 1 Ibm | 1 Security Guardium | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| IBM Security Guardium 10.5, 10.6, and 11.0 could allow an unauthorized user to obtain sensitive information due to missing security controls. IBM X-Force ID: 141226. | |||||
| CVE-2018-1164 | 1 Zyxel | 2 P-870h-51, P-870h-51 Firmware | 2026-06-17 | 10.0 HIGH | 9.8 CRITICAL |
| This vulnerability allows remote attackers to cause a denial-of-service condition on vulnerable installations of ZyXEL P-870H-51 DSL Router 1.00(AWG.3)D5. Authentication is not required to exploit this vulnerability. The specific flaw exists within numerous exposed CGI endpoints. The vulnerability is caused by improper access controls that allow access to critical functions without authentication. An attacker can use this vulnerability to reboot affected devices, along with other actions. Was ZDI-CAN-4540. | |||||
| CVE-2018-19636 | 1 Opensuse | 1 Supportutils | 2026-06-17 | 7.2 HIGH | 7.3 HIGH |
| Supportutils, before version 3.1-5.7.1, when run with command line argument -A searched the file system for a ndspath binary. If an attacker provides one at an arbitrary location it is executed with root privileges | |||||
| CVE-2018-19248 | 1 Epson | 2 Epson Workforce Wf-2861, Epson Workforce Wf-2861 Firmware | 2026-06-17 | 6.4 MEDIUM | 9.1 CRITICAL |
| The web service on Epson WorkForce WF-2861 10.48 LQ22I3(Recovery-mode), WF-2861 10.51.LQ20I6, and WF-2861 10.52.LQ17IA devices allows remote attackers to upload a firmware file and reset the printer without authentication by making a request to the /DOWN/FIRMWAREUPDATE/ROM1 URI and a POST request to the /FIRMWAREUPDATE URI. | |||||
| CVE-2018-19079 | 2 Foscam, Opticam | 6 C2, C2 Application Firmware, C2 System Firmware and 3 more | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The ONVIF devicemgmt SystemReboot method allows unauthenticated reboot. | |||||
| CVE-2018-18995 | 1 Abb | 4 Gate-e1, Gate-e1 Firmware, Gate-e2 and 1 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses. | |||||
| CVE-2018-18264 | 1 Kubernetes | 1 Dashboard | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| Kubernetes Dashboard before 1.10.1 allows attackers to bypass authentication and use Dashboard's Service Account for reading secrets within the cluster. | |||||
| CVE-2018-17924 | 1 Rockwellautomation | 32 1756-en2f Series A, 1756-en2f Series A Firmware, 1756-en2f Series B and 29 more | 2026-06-17 | 7.8 HIGH | 8.6 HIGH |
| Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address. | |||||
| CVE-2018-17906 | 1 Philips | 2 Intellispace Pacs, Isite Pacs | 2026-06-17 | 3.3 LOW | 8.8 HIGH |
| Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system. | |||||