| CVE-2024-5632 | 2026-06-17 | N/A | N/A | ||
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password. A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. | |||||
| CVE-2024-5245 | 1 Netgear | 1 Prosafe Network Management System | 2026-06-17 | N/A | 7.8 HIGH |
| NETGEAR ProSAFE Network Management System Default Credentials Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the product installer. The issue results from the use of default MySQL credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22755. | |||||
| CVE-2024-54015 | 2026-06-17 | N/A | 7.5 HIGH | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. | |||||
| CVE-2024-4622 | 2026-06-17 | N/A | N/A | ||
| If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator. | |||||
| CVE-2024-4007 | 1 Abb | 26 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 23 more | 2026-06-17 | N/A | 8.8 HIGH |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. | |||||
| CVE-2024-46899 | 2026-06-17 | N/A | 7.1 HIGH | ||
| Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04. | |||||
| CVE-2024-45068 | 2026-06-17 | N/A | 7.1 HIGH | ||
| Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA. This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01. | |||||
| CVE-2024-40113 | 1 Sitecom | 2 Wlx-2006, Wlx-2006 Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials. | |||||
| CVE-2024-39747 | 3 Ibm, Linux, Microsoft | 4 Aix, Sterling Connect Direct Web Services, Linux Kernel and 1 more | 2026-06-17 | N/A | 8.1 HIGH |
| IBM Sterling Connect:Direct Web Services 6.0, 6.1, 6.2, and 6.3 uses default credentials for potentially critical functionality. | |||||
| CVE-2024-39584 | 1 Dell | 40 Alienware Area 51m R2, Alienware Area 51m R2 Firmware, Alienware Aurora R13 and 37 more | 2026-06-17 | N/A | 8.2 HIGH |
| Dell Client Platform BIOS contains a Use of Default Cryptographic Key Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Secure Boot bypass and arbitrary code execution. | |||||
| CVE-2024-31069 | 2026-06-17 | N/A | 7.4 HIGH | ||
| IO-1020 Micro ELD web server uses a default password for authentication. | |||||
| CVE-2024-30210 | 2026-06-17 | N/A | 7.4 HIGH | ||
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device. | |||||
| CVE-2024-29844 | 1 Cs-technologies | 1 Evolution | 2026-06-17 | N/A | 9.8 CRITICAL |
| Default credentials on the Web Interface of Evolution Controller 2.x allows anyone to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the password. There is no warning or prompt to ask the user to change the default password. | |||||
| CVE-2024-28093 | 2026-06-17 | N/A | 8.8 HIGH | ||
| The TELNET service of AdTran NetVanta 3120 18.01.01.00.E devices is enabled by default, and has default credentials for a root-level account. | |||||
| CVE-2024-27158 | 2026-06-17 | N/A | 7.4 HIGH | ||
| All the Toshiba printers share the same hardcoded root password. As for the affected products/models/versions, see the reference URL. | |||||
| CVE-2024-13893 | 2026-06-17 | N/A | N/A | ||
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory. For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created. Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared. Newer firmware versions might be vulnerable as well. | |||||
| CVE-2024-12902 | 2026-06-17 | N/A | 8.4 HIGH | ||
| ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials. | |||||
| CVE-2024-12856 | 1 Four-faith | 4 F3x24, F3x24 Firmware, F3x36 and 1 more | 2026-06-17 | N/A | 7.2 HIGH |
| The Four-Faith router models F3x24 and F3x36 are affected by an operating system (OS) command injection vulnerability. At least firmware version 2.0 allows authenticated and remote attackers to execute arbitrary OS commands over HTTP when modifying the system time via apply.cgi. Additionally, this firmware version has default credentials which, if not changed, would effectively change this vulnerability into an unauthenticated and remote OS command execution issue. | |||||
| CVE-2024-12286 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. | |||||
| CVE-2024-12013 | 2026-06-17 | N/A | 7.6 HIGH | ||
| A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. | |||||