| CVE-2023-46288 | 1 Apache | 1 Airflow | 2026-06-17 | N/A | 4.3 MEDIUM |
| Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Apache Airflow.This issue affects Apache Airflow from 2.4.0 to 2.7.0. Sensitive configuration information has been exposed to authenticated users with the ability to read configuration via Airflow REST API for configuration even when the expose_config option is set to non-sensitive-only. The expose_config option is False by default. It is recommended to upgrade to a version that is not affected if you set expose_config to non-sensitive-only configuration. This is a different error than CVE-2023-45348 which allows authenticated user to retrieve individual configuration values in 2.7.* by specially crafting their request (solved in 2.7.2). Users are recommended to upgrade to version 2.7.2, which fixes the issue and additionally fixes CVE-2023-45348. | |||||
| CVE-2023-46287 | 1 Nagvis | 1 Nagvis | 2026-06-17 | N/A | 6.1 MEDIUM |
| XSS exists in NagVis before 1.9.38 via the select function in share/server/core/functions/html.php. | |||||
| CVE-2023-46285 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2026-06-17 | N/A | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. | |||||
| CVE-2023-46284 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2026-06-17 | N/A | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. | |||||
| CVE-2023-46283 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2026-06-17 | N/A | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. | |||||
| CVE-2023-46282 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2026-06-17 | N/A | 7.1 HIGH |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. | |||||
| CVE-2023-46281 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2026-06-17 | N/A | 7.1 HIGH |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior. | |||||
| CVE-2023-46280 | 2026-06-17 | N/A | 6.5 MEDIUM | ||
| A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2), SINEC NMS (All versions < V3.0 SP1). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. | |||||
| CVE-2023-46279 | 1 Apache | 1 Dubbo | 2026-06-17 | N/A | 9.8 CRITICAL |
| Deserialization of Untrusted Data vulnerability in Apache Dubbo.This issue only affects Apache Dubbo 3.1.5. Users are recommended to upgrade to the latest version, which fixes the issue. | |||||
| CVE-2023-46278 | 1 Cybozu | 1 Cybozu Remote Service | 2026-06-17 | N/A | 6.5 MEDIUM |
| Uncontrolled resource consumption vulnerability in Cybozu Remote Service 4.1.0 to 4.1.1 allows a remote authenticated attacker to consume huge storage space or cause significantly delayed communication. | |||||
| CVE-2023-46277 | 1 Edneville | 1 Please | 2026-06-17 | N/A | 7.8 HIGH |
| please (aka pleaser) through 0.5.4 allows privilege escalation through the TIOCSTI and/or TIOCLINUX ioctl. (If both TIOCSTI and TIOCLINUX are disabled, this cannot be exploited.) | |||||
| CVE-2023-46272 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Buffer Overflow vulnerability in Extreme Networks IQ Engine before 10.6r1a, and through 10.6r4 before 10.6r5, allows an attacker to execute arbitrary code via the implementation of the ah_auth service | |||||
| CVE-2023-46271 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| Extreme Networks IQ Engine before 10.6r1a, and through 10.6r4 before 10.6r5, has a buffer overflow. This issue arises from the ah_webui service, which listens on TCP port 3009 by default. | |||||
| CVE-2023-46270 | 2026-06-17 | N/A | 3.3 LOW | ||
| MacPaw The Unarchiver before 4.3.6 contains vulnerability related to missing quarantine attributes for extracted items. | |||||
| CVE-2023-46266 | 1 Ivanti | 1 Avalanche | 2026-06-17 | N/A | 9.1 CRITICAL |
| An attacker can send a specially crafted request which could lead to leakage of sensitive data or potentially a resource-based DoS attack. | |||||
| CVE-2023-46265 | 1 Ivanti | 1 Avalanche | 2026-06-17 | N/A | 9.8 CRITICAL |
| An unauthenticated could abuse a XXE vulnerability in the Smart Device Server to leak data or perform a Server-Side Request Forgery (SSRF). | |||||
| CVE-2023-46264 | 2 Ivanti, Microsoft | 2 Avalanche, Windows | 2026-06-17 | N/A | 9.8 CRITICAL |
| An unrestricted upload of file with dangerous type vulnerability exists in Avalanche versions 6.4.1 and below that could allow an attacker to achieve a remove code execution. | |||||
| CVE-2023-46263 | 2 Ivanti, Microsoft | 2 Avalanche, Windows | 2026-06-17 | N/A | 9.8 CRITICAL |
| An unrestricted upload of file with dangerous type vulnerability exists in Avalanche versions 6.4.1 and below that could allow an attacker to achieve a remote code execution. | |||||
| CVE-2023-46262 | 1 Ivanti | 1 Avalanche | 2026-06-17 | N/A | 7.5 HIGH |
| An unauthenticated attacked could send a specifically crafted web request causing a Server-Side Request Forgery (SSRF) in Ivanti Avalanche Remote Control server. | |||||
| CVE-2023-46261 | 2 Ivanti, Microsoft | 2 Avalanche, Windows | 2026-06-17 | N/A | 9.8 CRITICAL |
| An attacker sending specially crafted data packets to the Mobile Device Server can cause memory corruption which could result to a Denial of Service (DoS) or code execution. | |||||