Total
402865 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-51135 | 1 Totolink | 2 X2000r, X2000r Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| TOTOLINK X2000R Gh v1.0.0-B20230221.0948.web was discovered to contain a stack overflow via the function formPasswordSetup. | |||||
| CVE-2023-51133 | 1 Totolink | 2 X2000r, X2000r Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| TOTOLINK X2000R Gh v1.0.0-B20230221.0948.web was discovered to contain a stack overflow via the function formRoute. | |||||
| CVE-2023-51127 | 1 Flir | 2 Flir Ax8, Flir Ax8 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction. This vulnerability allows an unauthenticated, remote attacker to obtain arbitrary sensitive file contents by uploading a specially crafted symbolic link file. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16. | |||||
| CVE-2023-51126 | 1 Flir | 2 Flir Ax8, Flir Ax8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Command injection vulnerability in /usr/www/res.php in FLIR AX8 up to 1.46.16 allows attackers to run arbitrary commands via the value parameter. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16. | |||||
| CVE-2023-51123 | 1 Dlink | 2 Dir-815, Dir-815 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| An issue discovered in D-Link dir815 v.1.01SSb08.bin allows a remote attacker to execute arbitrary code via a crafted POST request to the service parameter in the soapcgi_main function of the cgibin binary component. | |||||
| CVE-2023-51107 | 1 Artifex | 1 Mupdf | 2026-06-17 | N/A | 7.5 HIGH |
| A floating point exception (divide-by-zero) vulnerability was discovered in Artifex MuPDF 1.23.4 in functon compute_color() of jquant2.c. NOTE: this is disputed by the supplier because there was not reasonable evidence to determine the existence of a vulnerability or identify the affected product. | |||||
| CVE-2023-51106 | 1 Artifex | 1 Mupdf | 2026-06-17 | N/A | 7.5 HIGH |
| A floating point exception (divide-by-zero) vulnerability was discovered in mupdf 1.23.4 in function pnm_binary_read_image() of load-pnm.c when fz_colorspace_n returns zero. | |||||
| CVE-2023-51105 | 1 Artifex | 1 Mupdf | 2026-06-17 | N/A | 7.5 HIGH |
| A floating point exception (divide-by-zero) vulnerability was discovered in Artifex MuPDF 1.23.4 in function bmp_decompress_rle4() of load-bmp.c. | |||||
| CVE-2023-51104 | 1 Artifex | 1 Mupdf | 2026-06-17 | N/A | 7.5 HIGH |
| A floating point exception (divide-by-zero) vulnerability was discovered in Artifex MuPDF 1.23.4 in function pnm_binary_read_image() of load-pnm.c when span equals zero. | |||||
| CVE-2023-51103 | 1 Artifex | 1 Mupdf | 2026-06-17 | N/A | 7.5 HIGH |
| A floating point exception (divide-by-zero) vulnerability was discovered in Artifex MuPDF 1.23.4 in the function fz_new_pixmap_from_float_data() of pixmap.c. | |||||
| CVE-2023-51102 | 1 Tenda | 2 W9, W9 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formWifiMacFilterSet. | |||||
| CVE-2023-51101 | 1 Tenda | 2 W9, W9 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetUplinkInfo. | |||||
| CVE-2023-51100 | 1 Tenda | 2 W9, W9 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formGetDiagnoseInfo . | |||||
| CVE-2023-51099 | 1 Tenda | 2 W9, W9 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formexeCommand . | |||||
| CVE-2023-51098 | 1 Tenda | 2 W9, W9 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formSetDiagnoseInfo . | |||||
| CVE-2023-51097 | 1 Tenda | 2 W9, W9 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetAutoPing. | |||||
| CVE-2023-51095 | 1 Tenda | 2 M3, M3 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function formDelWlRfPolicy. | |||||
| CVE-2023-51094 | 1 Tenda | 2 M3, M3 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a Command Execution vulnerability via the function TendaTelnet. | |||||
| CVE-2023-51093 | 1 Tenda | 2 M3, M3 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function fromSetLocalVlanInfo. | |||||
| CVE-2023-51092 | 1 Tenda | 2 M3, M3 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function upgrade. | |||||
