Vulnerabilities (CVE)

Total 397434 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-29966 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 7.5 HIGH
Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance's root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.
CVE-2024-29965 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 6.8 MEDIUM
In Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface ("SSH"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.
CVE-2024-29964 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 5.7 MEDIUM
Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files. An unprivileged attacker who gains access to the server can read sensitive information from these files.
CVE-2024-29963 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 1.9 LOW
Brocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn't have access to remote Docker registries.
CVE-2024-29962 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 5.5 MEDIUM
Brocade SANnav OVA before v2.3.1 and v2.3.0a have an insecure file permission setting that makes files world-readable. This could allow a local user without the required privileges to access sensitive information or a Java binary.
CVE-2024-29961 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 8.2 HIGH
A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.
CVE-2024-29960 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 6.8 MEDIUM
In Brocade SANnav server before v2.3.1 and v2.3.0a, the SSH keys inside the OVA image are identical in the VM every time SANnav is installed. Any Brocade SAnnav VM based on the official OVA images is vulnerable to MITM over SSH. An attacker can decrypt and compromise the SSH traffic to the SANnav.
CVE-2024-29959 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 8.6 HIGH
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node's support save.
CVE-2024-29958 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 7.5 HIGH
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node. This could provide attackers an additional, less protected path to acquiring the encryption key.
CVE-2024-29957 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 7.5 HIGH
When Brocade SANnav before v2.3.1 and v2.3.0a servers are configured in Disaster Recovery mode, the encryption key is stored in the DR log files. This could provide attackers with an additional, less-protected path to acquiring the encryption key.
CVE-2024-29956 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 6.5 MEDIUM
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the Brocade SANnav password in clear text in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav.
CVE-2024-29955 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 5.0 MEDIUM
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow a privileged user to print the SANnav encrypted key in PostgreSQL startup logs. This could provide attackers with an additional, less-protected path to acquiring the encryption key.
CVE-2024-29954 1 Broadcom 1 Fabric Operating System 2026-06-17 N/A 5.9 MEDIUM
A vulnerability in a password management API in Brocade Fabric OS versions before v9.2.1, v9.2.0b, v9.1.1d, and v8.2.3e prints sensitive information in log files. This could allow an authenticated user to view the server passwords for protocols such as scp and sftp. Detail. When the firmwaredownload command is incorrectly entered or points to an erroneous file, the firmware download log captures the failed command, including any password entered in the command line.
CVE-2024-29953 1 Broadcom 1 Fabric Operating System 2026-06-17 N/A 4.3 MEDIUM
A vulnerability in the web interface in Brocade Fabric OS before v9.2.1, v9.2.0b, and v9.1.1d prints encoded session passwords on session storage for Virtual Fabric platforms. This could allow an authenticated user to view other users' session encoded passwords.
CVE-2024-29952 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 5.5 MEDIUM
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow an authenticated user to print the Auth, Priv, and SSL key store passwords in unencrypted logs by manipulating command variables.
CVE-2024-29951 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 5.7 MEDIUM
Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.
CVE-2024-29950 1 Broadcom 1 Brocade Sannav 2026-06-17 N/A 7.5 HIGH
The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash. The vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.
CVE-2024-29949 2026-06-17 N/A 7.2 HIGH
There is a command injection vulnerability in some Hikvision NVRs. This could allow an authenticated user with administrative rights to execute arbitrary commands.
CVE-2024-29948 2026-06-17 N/A 3.8 LOW
There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality.
CVE-2024-29947 2026-06-17 N/A 2.7 LOW
There is a NULL dereference pointer vulnerability in some Hikvision NVRs. Due to an insufficient validation of a parameter in a message, an attacker may send specially crafted messages to an affected product, causing a process abnormality.