Vulnerabilities (CVE)

Total 395945 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-41806 2026-06-17 N/A 5.3 MEDIUM
The Open edX Platform is a learning management platform. Instructors can upload csv files containing learner information to create cohorts in the instructor dashboard. These files are uploaded using the django default storage. With certain storage backends, uploads may become publicly available when the uploader uses versions master, palm, olive, nutmeg, maple, lilac, koa, or juniper. The patch in commit cb729a3ced0404736dfa0ae768526c82b608657b ensures that cohorts data uploaded to AWS S3 buckets is written with a private ACL. Beyond patching, deployers should also ensure that existing cohorts uploads have a private ACL, or that other precautions are taken to avoid public access.
CVE-2024-41805 2026-06-17 N/A 6.1 MEDIUM
Tracks, a Getting Things Done (GTD) web application, is vulnerable to reflected cross-site scripting in versions prior to 2.7.1. Reflected cross-site scripting enables execution of malicious JavaScript in the context of a user’s browser if that user clicks on a malicious link, allowing phishing attacks that could lead to credential theft. Tracks version 2.7.1 is patched. No known complete workarounds are available.
CVE-2024-41804 1 Xibosignage 1 Xibo 2026-06-17 N/A 6.5 MEDIUM
Xibo is a content management system (CMS). An SQL injection vulnerability was discovered in the API route inside the CMS responsible for Adding/Editing DataSet Column Formulas. This allows an authenticated user to to obtain and modify arbitrary data from the Xibo database by injecting specially crafted values in to the `formula` parameter. Users should upgrade to version 3.3.12 or 4.0.14 which fix this issue.
CVE-2024-41803 1 Xibosignage 1 Xibo 2026-06-17 N/A 4.9 MEDIUM
Xibo is a content management system (CMS). An SQL injection vulnerability was discovered in the API routes inside the CMS responsible for Filtering DataSets. This allows an authenticated user to to obtain arbitrary data from the Xibo database by injecting specially crafted values in to the API for viewing DataSet data. Users should upgrade to version 3.3.12 or 4.0.14 which fix this issue.
CVE-2024-41802 1 Xibosignage 1 Xibo 2026-06-17 N/A 8.1 HIGH
Xibo is a content management system (CMS). An SQL injection vulnerability was discovered in the API routes inside the CMS responsible for Filtering DataSets. This allows an authenticated user to to obtain and modify arbitrary data from the Xibo database by injecting specially crafted values in to the APIs for importing JSON and importing a Layout containing DataSet data. Users should upgrade to version 3.3.12 or 4.0.14 which fix this issue
CVE-2024-41801 1 Openproject 1 Openproject 2026-06-17 N/A 4.7 MEDIUM
OpenProject is open source project management software. Prior to version 14.3.0, using a forged HOST header in the default configuration of packaged installations and using the "Login required" setting, an attacker could redirect to a remote host to initiate a phishing attack against an OpenProject user's account. This vulnerability affects default packaged installation of OpenProject without any additional configuration or modules on Apache (such as mod_security, manually setting a host name, having a fallthrough VirtualHost). It might also affect other installations that did not take care to fix the HOST/X-Forwarded-Host headers. Version 14.3.0 includes stronger protections for the hostname from within the application using the HostAuthorization middleware of Rails to reject any requests with a host name that does not match the configured one. Also, all generated links by the application are now ensured to use the built-in hostname. Users who aren't able to upgrade immediately may use mod_security for Apache2 or manually fix the Host and X-Forwarded-Host headers in their proxying application before reaching the application server of OpenProject. Alternatively, they can manually apply the patch to opt-in to host header protections in previous versions of OpenProject.
CVE-2024-41800 1 Craftcms 1 Craft Cms 2026-06-17 N/A 4.8 MEDIUM
Craft is a content management system (CMS). Craft CMS 5 allows reuse of TOTP tokens multiple times within the validity period. An attacker is able to re-submit a valid TOTP token to establish an authenticated session. This requires that the attacker has knowledge of the victim's credentials. This has been patched in Craft 5.2.3.
CVE-2024-41799 1 Tgstation13 1 Tgstation-server 2026-06-17 N/A 8.4 HIGH
tgstation-server is a production scale tool for BYOND server management. Prior to 6.8.0, low permission users using the "Set .dme Path" privilege could potentially set malicious .dme files existing on the host machine to be compiled and executed. These .dme files could be uploaded via tgstation-server (requiring a separate, isolated privilege) or some other means. A server configured to execute in BYOND's trusted security level (requiring a third separate, isolated privilege OR being set by another user) could lead to this escalating into remote code execution via BYOND's shell() proc. The ability to execute this kind of attack is a known side effect of having privileged TGS users, but normally requires multiple privileges with known weaknesses. This vector is not intentional as it does not require control over the where deployment code is sourced from and _may_ not require remote write access to an instance's `Configuration` directory. This problem is fixed in versions 6.8.0 and above.
CVE-2024-41798 2026-06-17 N/A 9.8 CRITICAL
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
CVE-2024-41797 2026-06-17 N/A 4.3 MEDIUM
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.1), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.1), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.1), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.1), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.1), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.1), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.1), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.1), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.1), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.1), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.1), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.1), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.1), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.1), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.1), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.1), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.1), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.1), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.1), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.1), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.1), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.1), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.1), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.1), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.1), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.1), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.1), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.1), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.1), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.1), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.1), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.1), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.1), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.1), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.1), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.1), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.1), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.1), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.1), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.1), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.1). Affected devices contain an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to invoke an internal "do system" command which exceeds their privileges. This command allows the execution of certain low-risk actions, the most critical of which is clearing the local system log.
CVE-2024-41796 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 6.5 MEDIUM
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack (CVE-2024-41795) an unauthenticated attacker could be able to set the password to an attacker-controlled value.
CVE-2024-41795 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 6.5 MEDIUM
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices is vulnerable to Cross-Site Request Forgery (CSRF) attacks. This could allow an unauthenticated attacker to change arbitrary device settings by tricking a legitimate device administrator to click on a malicious link.
CVE-2024-41794 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 10.0 CRITICAL
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).
CVE-2024-41793 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 8.6 HIGH
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could allow an unauthenticated remote attacker to enable remote access to the device via ssh.
CVE-2024-41792 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 8.6 HIGH
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges.
CVE-2024-41791 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 7.3 HIGH
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not authenticate report creation requests. This could allow an unauthenticated remote attacker to read or clear the log files on the device, reset the device or set the date and time.
CVE-2024-41790 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 9.1 CRITICAL
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2024-41789 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 9.1 CRITICAL
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the language parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2024-41788 1 Siemens 2 7kt Pac1260 Data Manager, 7kt Pac1260 Data Manager Firmware 2026-06-17 N/A 9.1 CRITICAL
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2024-41787 1 Ibm 1 Doors Next 2026-06-17 N/A 9.8 CRITICAL
IBM Engineering Requirements Management DOORS Next 7.0.2 and 7.0.3 could allow a remote attacker to bypass security restrictions, caused by a race condition. By sending a specially crafted request, an attacker could exploit this vulnerability to remotely execute code.