Vulnerabilities (CVE)

Total 395538 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-47917 2026-06-17 N/A 7.5 HIGH
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-47916 2026-06-17 N/A 7.5 HIGH
Boa web server - CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-47915 2026-06-17 N/A 7.5 HIGH
VaeMendis - CWE-200: Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-47914 2026-06-17 N/A 4.5 MEDIUM
VaeMendis - CWE-352: Cross-Site Request Forgery (CSRF)
CVE-2024-47913 1 Mediawiki 1 Mediawiki 2026-06-17 N/A 5.3 MEDIUM
An issue was discovered in the AbuseFilter extension for MediaWiki before 1.39.9, 1.40.x and 1.41.x before 1.41.3, and 1.42.x before 1.42.2. An API caller can match a filter condition against AbuseFilter logs even if the caller is not authorized to view the log details for the filter.
CVE-2024-47912 1 Mitel 1 Micollab 2026-06-17 N/A 8.2 HIGH
A vulnerability in the AWV (Audio, Web, and Video) Conferencing component of Mitel MiCollab through 9.8 SP1 FP2 (9.8.1.201) could allow an unauthenticated attacker to perform unauthorized data-access attacks due to missing authentication mechanisms. A successful exploit could allow an attacker to access and delete sensitive information.
CVE-2024-47911 1 Sonarsource 1 Sonarqube 2026-06-17 N/A 6.7 MEDIUM
In SonarSource SonarQube 10.4 through 10.5 before 10.6, a vulnerability was discovered in the authorizations/group-memberships API endpoint that allows SonarQube users with the administrator role to inject blind SQL commands.
CVE-2024-47910 2026-06-17 N/A 7.2 HIGH
An issue was discovered in SonarSource SonarQube before 9.9.5 LTA and 10.x before 10.5. A SonarQube user with the Administrator role can modify an existing configuration of a GitHub integration to exfiltrate a pre-signed JWT.
CVE-2024-47909 1 Ivanti 2 Connect Secure, Policy Secure 2026-06-17 N/A 4.9 MEDIUM
A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.3 and Ivanti Policy Secure before version 22.7R1.2 allows a remote authenticated attacker with admin privileges to cause a denial of service.
CVE-2024-47908 1 Ivanti 1 Cloud Services Appliance 2026-06-17 N/A 9.1 CRITICAL
OS command injection in the admin web console of Ivanti CSA before version 5.0.5 allows a remote authenticated attacker with admin privileges to achieve remote code execution.
CVE-2024-47907 1 Ivanti 1 Connect Secure 2026-06-17 N/A 7.5 HIGH
A stack-based buffer overflow in IPsec of Ivanti Connect Secure before version 22.7R2.3 allows a remote unauthenticated attacker to cause a denial of service.
CVE-2024-47906 1 Ivanti 2 Connect Secure, Policy Secure 2026-06-17 N/A 7.8 HIGH
Excessive binary privileges in Ivanti Connect Secure before version 22.7R2.3 (Not Applicable to 9.1Rx) and Ivanti Policy Secure before version 22.7R1.2 (Not Applicable to 9.1Rx) allows a local authenticated attacker to escalate privileges.
CVE-2024-47905 1 Ivanti 2 Connect Secure, Policy Secure 2026-06-17 N/A 4.9 MEDIUM
A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.3 and Ivanti Policy Secure before version 22.7R1.2 allows a remote authenticated attacker with admin privileges to cause a denial of service.
CVE-2024-47904 1 Siemens 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.
CVE-2024-47903 1 Siemens 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware 2026-06-17 N/A 5.8 MEDIUM
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices allows to write arbitrary files to the web server's DocumentRoot directory.
CVE-2024-47902 1 Siemens 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware 2026-06-17 N/A 7.2 HIGH
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.
CVE-2024-47901 1 Siemens 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware 2026-06-17 N/A 10.0 CRITICAL
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
CVE-2024-47900 2026-06-17 N/A 7.8 HIGH
Software installed and run as a non-privileged user may conduct improper GPU system calls to access OOB kernel memory.
CVE-2024-47899 2026-06-17 N/A 7.8 HIGH
Software installed and run as a non-privileged user may conduct improper GPU system calls to trigger use-after-free kernel exceptions.
CVE-2024-47898 2026-06-17 N/A 7.8 HIGH
Software installed and run as a non-privileged user may conduct improper GPU system calls to trigger use-after-free kernel exceptions.