CVE-2018-10599 1 Philips 36 Avalon Fetal\/maternal Monitors Fm20, Avalon Fetal\/maternal Monitors Fm20 Firmware, Avalon Fetal\/maternal Monitors Fm30 and 33 more 2026-06-17 2.9 LOW 5.3 MEDIUM
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
CVE-2018-10597 1 Philips 36 Avalon Fetal\/maternal Monitors Fm20, Avalon Fetal\/maternal Monitors Fm20 Firmware, Avalon Fetal\/maternal Monitors Fm30 and 33 more 2026-06-17 5.4 MEDIUM 8.3 HIGH
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
CVE-2017-9658 1 Philips 2 Intellivue Mx40, Intellivue Mx40 Firmware 2026-06-17 6.1 MEDIUM 6.5 MEDIUM
Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
CVE-2017-9657 1 Philips 2 Intellivue Mx40, Intellivue Mx40 Firmware 2026-06-17 3.3 LOW 6.5 MEDIUM
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
CVE-2017-9656 1 Philips 1 Dosewise 2026-06-17 6.5 MEDIUM 9.1 CRITICAL
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.
CVE-2017-9654 1 Philips 1 Dosewise 2026-06-17 4.0 MEDIUM 8.8 HIGH
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
CVE-2017-3210 4 Fujitsu, Hp, Philips and 1 more 6 Displayview Click, Displayview Click Suite, Display Assistant and 3 more 2026-06-17 7.2 HIGH 7.8 HIGH
Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applications run the component pdiservice.exe with NT AUTHORITY/SYSTEM permissions. This component is also read/writable by all Authenticated Users. This allows local authenticated attackers to run arbitrary code with SYSTEM privileges. The following applications have been identified by Portrait Displays as affected: Fujitsu DisplayView Click: Version 6.0 and 6.01. The issue was fixed in Version 6.3. Fujitsu DisplayView Click Suite: Version 5. The issue is addressed by patch in Version 5.9. HP Display Assistant: Version 2.1. The issue was fixed in Version 2.11. HP My Display: Version 2.0. The issue was fixed in Version 2.1. Philips Smart Control Premium: Versions 2.23, 2.25. The issue was fixed in Version 2.26.
CVE-2017-14797 1 Philips 2 Hue Bridge Bsb002, Hue Bridge Bsb002 Firmware 2026-06-17 7.9 HIGH 7.5 HIGH
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network.
CVE-2017-14111 1 Philips 2 Intellispace Cardiovascular, Xcelera 2026-06-17 4.0 MEDIUM 7.2 HIGH
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
CVE-2017-0199 2 Microsoft, Philips 6 Office, Windows 7, Windows Server 2008 and 3 more 2026-06-17 9.3 HIGH 7.8 HIGH
Microsoft Office 2007 SP3, Microsoft Office 2010 SP2, Microsoft Office 2013 SP1, Microsoft Office 2016, Microsoft Windows Vista SP2, Windows Server 2008 SP2, Windows 7 SP1, Windows 8.1 allow remote attackers to execute arbitrary code via a crafted document, aka "Microsoft Office/WordPad Remote Code Execution Vulnerability w/Windows API."
CVE-2017-0143 3 Microsoft, Philips, Siemens 28 Server Message Block, Windows 10 1507, Windows 10 1511 and 25 more 2026-06-17 9.3 HIGH 8.8 HIGH
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148.
CVE-2015-2884 1 Philips 1 In.sight B120\\37 2026-06-17 5.0 MEDIUM 7.5 HIGH
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
CVE-2015-2883 1 Philips 1 In.sight B120\\37 2026-06-17 3.5 LOW 5.4 MEDIUM
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
CVE-2015-2882 1 Philips 1 In.sight B120\\37 2026-06-17 10.0 HIGH 9.8 CRITICAL
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
CVE-2013-2808 1 Philips 4 Xper Flex Cardio, Xper Information Management Physiomonitoring 5, Xper Information Management Vascular Monitoring 5 and 1 more 2026-06-16 9.3 HIGH N/A
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.