Total
398576 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-40841 | 1 Ericsson | 2 Indoor Connect 8855, Indoor Connect 8855 Firmware | 2026-06-17 | N/A | 4.3 MEDIUM |
| Ericsson Indoor Connect 8855 versions prior to 2025.Q3 contains a Cross-Site Request Forgery (CSRF) vulnerability which, if exploited, can lead to unauthorized modification of certain information. | |||||
| CVE-2025-40838 | 1 Ericsson | 2 Indoor Connect 8855, Indoor Connect 8855 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| Ericsson Indoor Connect 8855 contains a vulnerability where server-side security can be bypassed in the client which if exploited can lead to unauthorized disclosure of certain information. | |||||
| CVE-2025-40837 | 1 Ericsson | 2 Indoor Connect 8855, Indoor Connect 8855 Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| Ericsson Indoor Connect 8855 contains a missing authorization vulnerability which if exploited can allow access to the system as a user with higher privileges than intended. | |||||
| CVE-2025-40836 | 1 Ericsson | 2 Indoor Connect 8855, Indoor Connect 8855 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Ericsson Indoor Connect 8855 contains an improper input validation vulnerability which if exploited can allow an attacker to execute commands with escalated privileges. | |||||
| CVE-2025-40834 | 2026-06-17 | N/A | 5.7 MEDIUM | ||
| A vulnerability has been identified in Mendix RichText (All versions >= V4.0.0 < V4.6.1). Affected widget does not properly neutralize the input. This could allow an attacker to execute cross-site scripting attacks. | |||||
| CVE-2025-40831 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 6.5 MEDIUM |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality. | |||||
| CVE-2025-40830 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor. | |||||
| CVE-2025-40829 | 1 Siemens | 1 Simcenter Femap | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146) | |||||
| CVE-2025-40827 | 2026-06-17 | N/A | 7.8 HIGH | ||
| A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. | |||||
| CVE-2025-40820 | 2026-06-17 | N/A | 7.5 HIGH | ||
| Affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of service. The attack succeeds only if an attacker can inject IP packets with spoofed addresses at precisely timed moments, and it affects only TCP-based services. | |||||
| CVE-2025-40819 | 1 Siemens | 1 Sinema Remote Connect Server | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications do not properly validate license restrictions against the database, allowing direct modification of the system_ticketinfo table to bypass license limitations without proper enforcement checks. This could allow with database access to circumvent licensing restrictions by directly modifying database values and potentially enabling unauthorized use beyond the permitted scope. | |||||
| CVE-2025-40818 | 1 Siemens | 1 Sinema Remote Connect Server | 2026-06-17 | N/A | 3.3 LOW |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates. | |||||
| CVE-2025-40817 | 2026-06-17 | N/A | 6.5 MEDIUM | ||
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. | |||||
| CVE-2025-40816 | 2026-06-17 | N/A | 7.6 HIGH | ||
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. | |||||
| CVE-2025-40815 | 2026-06-17 | N/A | 7.2 HIGH | ||
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. | |||||
| CVE-2025-40812 | 1 Siemens | 2 Solid Edge Se2024, Solid Edge Se2025 | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process. | |||||
| CVE-2025-40811 | 1 Siemens | 2 Solid Edge Se2024, Solid Edge Se2025 | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process. | |||||
| CVE-2025-40810 | 1 Siemens | 2 Solid Edge Se2024, Solid Edge Se2025 | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process. | |||||
| CVE-2025-40809 | 1 Siemens | 2 Solid Edge Se2024, Solid Edge Se2025 | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process. | |||||
| CVE-2025-40807 | 1 Siemens | 1 Gridscale X Prepay | 2026-06-17 | N/A | 6.3 MEDIUM |
| A vulnerability has been identified in Gridscale X Prepay (All versions < V4.2.1). The affected application is vulnerable to capture-replay of authentication tokens. This could allow an authenticated but already locked-out user to establish still valid user sessions. | |||||
