Filtered by vendor Schneider-electric
Subscribe
Total
780 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2026-2401 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-06-17 | N/A | 5.0 MEDIUM |
| CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker. | |||||
| CVE-2026-2400 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-06-17 | N/A | 4.3 MEDIUM |
| CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload. | |||||
| CVE-2026-2399 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-06-17 | N/A | 6.1 MEDIUM |
| CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload. | |||||
| CVE-2024-9409 | 1 Schneider-electric | 6 Powerlogic Pm5320, Powerlogic Pm5320 Firmware, Powerlogic Pm5340 and 3 more | 2026-06-17 | N/A | 7.5 HIGH |
| CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network. | |||||
| CVE-2024-8422 | 1 Schneider-electric | 1 Zelio Soft 2 | 2026-06-17 | N/A | 7.8 HIGH |
| CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when application user opens a malicious Zelio Soft 2 project file. | |||||
| CVE-2024-8306 | 1 Schneider-electric | 2 Vijeo Designer, Vijeo Designer Embedded In Ecostruxure Machine Expert | 2026-06-17 | N/A | 7.8 HIGH |
| CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries. | |||||
| CVE-2024-6528 | 1 Schneider-electric | 10 Modicon Lmc058, Modicon Lmc058 Firmware, Modicon M241 and 7 more | 2026-06-17 | N/A | 5.4 MEDIUM |
| CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload. | |||||
| CVE-2024-6407 | 1 Schneider-electric | 2 Whc-5918a, Whc-5918a Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device. | |||||
| CVE-2024-5681 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2026-06-17 | N/A | 7.8 HIGH |
| CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | |||||
| CVE-2024-5680 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2026-06-17 | N/A | 7.1 HIGH |
| CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | |||||
| CVE-2024-5679 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2026-06-17 | N/A | 7.1 HIGH |
| CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or kernel memory leak when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | |||||
| CVE-2024-5560 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2026-06-17 | N/A | 5.3 MEDIUM |
| CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request. | |||||
| CVE-2024-5559 | 1 Schneider-electric | 2 Powerlogic P5, Powerlogic P5 Firmware | 2026-06-17 | N/A | 6.1 MEDIUM |
| CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device. | |||||
| CVE-2024-5558 | 1 Schneider-electric | 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more | 2026-06-17 | N/A | 6.4 MEDIUM |
| CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account. | |||||
| CVE-2024-5557 | 1 Schneider-electric | 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more | 2026-06-17 | N/A | 4.5 MEDIUM |
| CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause exposure of SNMP credentials when an attacker has access to the controller logs. | |||||
| CVE-2024-5313 | 1 Schneider-electric | 2 Evlink Home, Evlink Home Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface. | |||||
| CVE-2024-5056 | 1 Schneider-electric | 6 Bmxnoe0100, Bmxnoe0100 Firmware, Bmxnoe0110 and 3 more | 2026-06-17 | N/A | 6.5 MEDIUM |
| CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem. | |||||
| CVE-2024-37040 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2026-06-17 | N/A | 5.4 MEDIUM |
| CWE-120: Buffer Copy without Checking Size of Input (‘Classic Buffer Overflow’) vulnerability exists that could allow a user with access to the device’s web interface to cause a fault on the device when sending a malformed HTTP request. | |||||
| CVE-2024-37039 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2026-06-17 | N/A | 5.9 MEDIUM |
| CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request. | |||||
| CVE-2024-37038 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2026-06-17 | N/A | 7.5 HIGH |
| CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests. | |||||