Total
48 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-25668 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function. | |||||
| CVE-2025-25667 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info. | |||||
| CVE-2025-25664 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function. | |||||
| CVE-2025-25663 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. | |||||
| CVE-2025-25510 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function. | |||||
| CVE-2025-1853 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-12618 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-0528 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac18 and 3 more | 2026-06-17 | 8.3 HIGH | 7.2 HIGH |
| A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2024-57704 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. | |||||
| CVE-2024-57703 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. | |||||
| CVE-2024-4066 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-4065 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-4064 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-46652 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. | |||||
| CVE-2024-11745 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2024-10280 | 1 Tenda | 20 Ac10, Ac10 Firmware, Ac10u and 17 more | 2026-06-17 | 6.8 MEDIUM | 6.5 MEDIUM |
| A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2024-10130 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-10123 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2023-4744 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability. | |||||
| CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. | |||||