| CVE-2025-11324 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used. | |||||
| CVE-2025-11123 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used. | |||||
| CVE-2025-11122 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used. | |||||
| CVE-2025-11121 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. | |||||
| CVE-2025-11120 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited. | |||||
| CVE-2025-0528 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac18 and 3 more | 2026-06-17 | 8.3 HIGH | 7.2 HIGH |
| A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2024-57583 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function. | |||||
| CVE-2024-57582 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function. | |||||
| CVE-2024-57581 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | |||||
| CVE-2024-57580 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function. | |||||
| CVE-2024-57579 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function. | |||||
| CVE-2024-57578 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function. | |||||
| CVE-2024-57577 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 5.7 MEDIUM |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
| CVE-2024-57575 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | |||||
| CVE-2024-41630 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 7.6 HIGH |
| Stack-based buffer overflow vulnerability in Tenda AC18 V15.03.3.10_EN allows a remote attacker to execute arbitrary code via the ssid parameter at ip/goform/fast_setting_wifi_set. | |||||
| CVE-2024-34974 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 8.2 HIGH |
| Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter. | |||||
| CVE-2024-33835 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function. | |||||
| CVE-2024-33181 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter. | |||||
| CVE-2024-30891 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution. | |||||
| CVE-2024-2854 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||