Vulnerabilities (CVE)

Total 395959 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2011-4897 1 Tor 1 Tor 2026-06-16 4.3 MEDIUM N/A
Tor before 0.2.2.25-alpha, when configured as a relay without the Nickname configuration option, uses the local hostname as the Nickname value, which allows remote attackers to obtain potentially sensitive information by reading this value.
CVE-2011-4896 1 Tor 1 Tor 2026-06-16 4.3 MEDIUM N/A
Tor before 0.2.2.24-alpha continues to use a reachable bridge that was previously configured but is not currently configured, which might allow remote attackers to obtain sensitive information about clients in opportunistic circumstances by monitoring network traffic to the bridge port.
CVE-2011-4895 1 Tor 1 Tor 2026-06-16 4.3 MEDIUM N/A
Tor before 0.2.2.34, when configured as a bridge, sets up circuits through a process different from the process used by a client, which makes it easier for remote attackers to enumerate bridges by observing circuit building.
CVE-2011-4894 1 Tor 1 Tor 2026-06-16 4.3 MEDIUM N/A
Tor before 0.2.2.34, when configured as a bridge, uses direct DirPort access instead of a Tor TLS connection for a directory fetch, which makes it easier for remote attackers to enumerate bridges by observing DirPort connections.
CVE-2011-4890 1 Ibm 1 Soliddb 2026-06-16 4.0 MEDIUM N/A
The server in IBM solidDB 6.5 before FP9 and 7.0 before FP1 allows remote authenticated users to cause a denial of service (daemon crash) via a SELECT statement with a ROWNUM condition involving a subquery.
CVE-2011-4889 1 Ibm 1 Websphere Application Server 2026-06-16 7.5 HIGH 9.8 CRITICAL
The javax.naming.directory.AttributeInUseException class in the Virtual Member Manager in IBM WebSphere Application Server (WAS) 6.1 before 6.1.0.43, 7.0 before 7.0.0.21, and 8.0 before 8.0.0.2 does not properly update passwords on a configuration using Tivoli Directory Server, which might allow remote attackers to gain access to an application by leveraging knowledge of an old password. IBM X-Force ID: 72581.
CVE-2011-4887 1 Imperva 1 Securesphere Web Application Firewall 2026-06-16 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the Violations Table in the management GUI in the MX Management Server in Imperva SecureSphere Web Application Firewall (WAF) 9.0 allows remote attackers to inject arbitrary web script or HTML via the username field.
CVE-2011-4885 1 Php 1 Php 2026-06-16 5.0 MEDIUM N/A
PHP before 5.3.9 computes hash values for form parameters without restricting the ability to trigger hash collisions predictably, which allows remote attackers to cause a denial of service (CPU consumption) by sending many crafted parameters.
CVE-2011-4883 1 Atvise 1 Webmi2ads 2026-06-16 5.0 MEDIUM N/A
The web server in Certec atvise webMI2ADS (aka webMI) before 2.0.2 does not properly validate values in HTTP requests, which allows remote attackers to cause a denial of service (resource consumption) via a crafted request.
CVE-2011-4882 1 Atvise 1 Webmi2ads 2026-06-16 5.0 MEDIUM N/A
The web server in Certec atvise webMI2ADS (aka webMI) before 2.0.2 allows remote attackers to cause a denial of service (application exit) via an unspecified command in an HTTP request.
CVE-2011-4881 1 Atvise 1 Webmi2ads 2026-06-16 5.0 MEDIUM N/A
The web server in Certec atvise webMI2ADS (aka webMI) before 2.0.2 does not properly check return values from functions, which allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted HTTP request.
CVE-2011-4880 1 Atvise 1 Webmi2ads 2026-06-16 5.0 MEDIUM N/A
Directory traversal vulnerability in the web server in Certec atvise webMI2ADS (aka webMI) before 2.0.2 allows remote attackers to read arbitrary files via a crafted HTTP request.
CVE-2011-4879 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2026-06-16 8.5 HIGH N/A
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
CVE-2011-4878 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2026-06-16 7.8 HIGH N/A
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
CVE-2011-4877 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2026-06-16 7.1 HIGH N/A
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
CVE-2011-4876 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2026-06-16 9.3 HIGH N/A
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
CVE-2011-4875 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2026-06-16 9.3 HIGH N/A
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
CVE-2011-4874 1 Microsys 1 Promotic 2026-06-16 7.9 HIGH N/A
Use-after-free vulnerability in MICROSYS PROMOTIC before 8.1.7 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service (data corruption and application crash) via a crafted project (aka .pra) file.
CVE-2011-4873 1 Atvise 1 Atvise 2026-06-16 5.0 MEDIUM N/A
Unspecified vulnerability in the server in Certec EDV atvise before 2.1 allows remote attackers to cause a denial of service (daemon crash) via crafted requests to TCP port 4840.
CVE-2011-4872 1 Htc 9 Desire Hd, Desire S, Droid Incredible and 6 more 2026-06-16 2.6 LOW N/A
Multiple HTC Android devices including Desire HD FRG83D and GRI40, Glacier FRG83, Droid Incredible FRF91, Thunderbolt 4G FRG83D, Sensation Z710e GRI40, Sensation 4G GRI40, Desire S GRI40, EVO 3D GRI40, and EVO 4G GRI40 allow remote attackers to obtain 802.1X Wi-Fi credentials and SSID via a crafted application that uses the android.permission.ACCESS_WIFI_STATE permission to call the toString method on the WifiConfiguration class.