CVE-2014-2380 1 Invensys 1 Wonderware Information Server 2026-06-17 7.8 HIGH N/A
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file.
CVE-2014-2379 1 Sensysnetworks 4 Trafficdot, Vds, Vsn240-f and 1 more 2026-06-17 4.3 MEDIUM N/A
Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not use encryption, which allows remote attackers to interfere with traffic control by replaying transmissions on a wireless network.
CVE-2014-2378 1 Sensysnetworks 4 Trafficdot, Vds, Vsn240-f and 1 more 2026-06-17 6.5 MEDIUM N/A
Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not verify the integrity of downloaded updates, which allows remote attackers to execute arbitrary code via a Trojan horse update.
CVE-2014-2377 1 Ecava 1 Integraxor 2026-06-17 5.0 MEDIUM N/A
Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to discover full pathnames via an application tag.
CVE-2014-2376 1 Ecava 1 Integraxor 2026-06-17 7.5 HIGH N/A
SQL injection vulnerability in Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
CVE-2014-2375 1 Ecava 1 Integraxor 2026-06-17 8.3 HIGH N/A
Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to read or write to arbitrary files, and obtain sensitive information or cause a denial of service (disk consumption), via the CSV export feature.
CVE-2014-2374 1 Accuenergy 2 Acuvim Ii, Axm-net 2026-06-17 7.5 HIGH N/A
The AXN-NET Ethernet module accessory 3.04 for the Accuenergy Acuvim II allows remote attackers to discover passwords and modify settings via vectors involving JavaScript.
CVE-2014-2373 1 Accuenergy 2 Acuvim Ii, Axm-net 2026-06-17 7.5 HIGH N/A
The AXN-NET Ethernet module accessory 3.04 for the Accuenergy Acuvim II allows remote attackers to discover passwords and modify settings via vectors involving JavaScript.
CVE-2014-2370 1 Omron 6 Ns10 Hmi Terminal, Ns12 Hmi Terminal, Ns15 Hmi Terminal and 3 more 2026-06-17 4.0 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
CVE-2014-2369 1 Omron 6 Ns10 Hmi Terminal, Ns12 Hmi Terminal, Ns15 Hmi Terminal and 3 more 2026-06-17 4.6 MEDIUM N/A
Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.
CVE-2014-2368 1 Advantech 1 Advantech Webaccess 2026-06-17 7.5 HIGH N/A
The BrowseFolder method in the bwocxrun ActiveX control in Advantech WebAccess before 7.2 allows remote attackers to read arbitrary files via a crafted call.
CVE-2014-2367 1 Advantech 1 Advantech Webaccess 2026-06-17 7.5 HIGH N/A
The ChkCookie subroutine in an ActiveX control in broadweb/include/gChkCook.asp in Advantech WebAccess before 7.2 allows remote attackers to read arbitrary files via a crafted call.
CVE-2014-2366 1 Advantech 1 Advantech Webaccess 2026-06-17 9.0 HIGH N/A
upAdminPg.asp in Advantech WebAccess before 7.2 allows remote authenticated users to discover credentials by reading HTML source code.
CVE-2014-2365 1 Advantech 1 Advantech Webaccess 2026-06-17 6.5 MEDIUM N/A
Unspecified vulnerability in Advantech WebAccess before 7.2 allows remote authenticated users to create or delete arbitrary files via unknown vectors.
CVE-2014-2364 1 Advantech 1 Advantech Webaccess 2026-06-17 7.5 HIGH N/A
Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx.
CVE-2014-2363 1 Morpho 1 Itemiser 3 2026-06-17 10.0 HIGH N/A
Morpho Itemiser 3 8.17 has hardcoded administrative credentials, which makes it easier for remote attackers to obtain access via a login request.
CVE-2014-2362 1 Oleumtech 2 Sensor Wireless I\/o Module, Wio Dh2 Wireless Gateway 2026-06-17 7.8 HIGH N/A
OleumTech WIO DH2 Wireless Gateway and Sensor Wireless I/O Modules rely exclusively on a time value for entropy in key generation, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by predicting the time of project creation.
CVE-2014-2361 1 Oleumtech 2 Sensor Wireless I\/o Module, Wio Dh2 Wireless Gateway 2026-06-17 7.2 HIGH N/A
OleumTech WIO DH2 Wireless Gateway and Sensor Wireless I/O Modules, when BreeZ is used, do not require authentication for reading the site security key, which allows physically proximate attackers to spoof communication by obtaining this key after use of direct hardware access or manual-setup mode.
CVE-2014-2360 1 Oleumtech 2 Sensor Wireless I\/o Module, Wio Dh2 Wireless Gateway 2026-06-17 5.0 MEDIUM N/A
OleumTech WIO DH2 Wireless Gateway and Sensor Wireless I/O Modules allow remote attackers to execute arbitrary code via packets that report a high battery voltage.
CVE-2014-2359 1 Oleumtech 4 Ad1, Ad1 Firmware, Ft1 and 1 more 2026-06-17 4.3 MEDIUM 5.9 MEDIUM
OleumTech Wireless Sensor Network devices allow remote attackers to obtain sensitive information about sensor nodes or spoof devices by reading cleartext protocol data.