Vulnerabilities (CVE)

Total 398899 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-12754 1 Asuswrt-merlin 29 Asuswrt-merlin, Rt-ac1200, Rt-ac3100 and 26 more 2026-06-17 6.5 MEDIUM 8.8 HIGH
Stack buffer overflow in httpd in Asuswrt-Merlin firmware 380.67_0RT-AC5300 and earlier for ASUS devices and ASUS firmware for ASUS RT-AC5300, RT_AC1900P, RT-AC68U, RT-AC68P, RT-AC88U, RT-AC66U, RT-AC66U_B1, RT-AC58U, RT-AC56U, RT-AC55U, RT-AC52U, RT-AC51U, RT-N18U, RT-N66U, RT-N56U, RT-AC3200, RT-AC3100, RT_AC1200GU, RT_AC1200G, RT-AC1200, RT-AC53, RT-N12HP, RT-N12HP_B1, RT-N12D1, RT-N12+, RT_N12+_PRO, RT-N16, and RT-N300 devices allows remote attackers to execute arbitrary code on the router by sending a crafted http GET request packet that includes a long delete_offline_client parameter in the url.
CVE-2017-12741 1 Siemens 76 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200p and 73 more 2026-06-17 7.8 HIGH 7.5 HIGH
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
CVE-2017-12740 1 Siemens 1 Logo\! Soft Comfort 2026-06-17 4.3 MEDIUM 5.9 MEDIUM
Siemens LOGO! Soft Comfort (All versions before V8.2) lacks integrity verification of software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a Man-in-the-Middle (MitM) attack.
CVE-2017-12739 1 Siemens 2 Sm-2556, Sm-2556 Firmware 2026-06-17 10.0 HIGH 9.8 CRITICAL
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device.
CVE-2017-12738 1 Siemens 2 Sm-2556, Sm-2556 Firmware 2026-06-17 4.3 MEDIUM 6.1 MEDIUM
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.
CVE-2017-12737 1 Siemens 2 Sm-2556, Sm-2556 Firmware 2026-06-17 5.0 MEDIUM 5.3 MEDIUM
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.
CVE-2017-12736 1 Siemens 15 Ruggedcom, Ruggedcom Ros, Ruggedcom Rsl910 and 12 more 2026-06-17 5.8 MEDIUM 8.8 HIGH
After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.
CVE-2017-12735 1 Siemens 2 Logo\!, Logo\! 8 Bm Firmware 2026-06-17 5.8 MEDIUM 7.4 HIGH
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic.
CVE-2017-12734 1 Siemens 2 Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware 2026-06-17 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.
CVE-2017-12733 1 Opwglobal 6 Sitesentinel Integra 100, Sitesentinel Integra 100 Firmware, Sitesentinel Integra 500 and 3 more 2026-06-17 7.5 HIGH 9.8 CRITICAL
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
CVE-2017-12732 1 Ge 1 Intelligent Platforms Proficy Hmi\/scada Cimplicity 2026-06-17 4.9 MEDIUM 6.8 MEDIUM
A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution.
CVE-2017-12731 1 Opwglobal 6 Sitesentinel Integra 100, Sitesentinel Integra 100 Firmware, Sitesentinel Integra 500 and 3 more 2026-06-17 7.5 HIGH 9.8 CRITICAL
A SQL Injection issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. The application is vulnerable to injection of malicious SQL queries via the input from the client.
CVE-2017-12730 1 Myscada 1 Mypro 2026-06-17 7.2 HIGH 7.8 HIGH
An Unquoted Search Path issue was discovered in mySCADA myPRO Versions 7.0.26 and prior. Application services utilize unquoted search path elements, which could allow an attacker to execute arbitrary code with elevated privileges.
CVE-2017-12729 1 Moxa 1 Softcms Lab View 2026-06-17 7.5 HIGH 9.8 CRITICAL
A SQL Injection issue was discovered in Moxa SoftCMS Live Viewer through 1.6. An improper neutralization of special elements used in an SQL command ('SQL Injection') vulnerability has been identified. Attackers can exploit this vulnerability to access SoftCMS without knowing the user's password.
CVE-2017-12728 1 Spidercontrol 1 Scada Webserver 2026-06-17 7.2 HIGH 7.8 HIGH
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services.
CVE-2017-12726 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2026-06-17 7.5 HIGH 7.3 HIGH
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.
CVE-2017-12725 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2026-06-17 6.8 MEDIUM 5.6 MEDIUM
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.
CVE-2017-12724 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2026-06-17 6.8 MEDIUM 8.1 HIGH
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.
CVE-2017-12723 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2026-06-17 4.3 MEDIUM 3.7 LOW
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
CVE-2017-12722 1 Smiths-medical 1 Medfusion 4000 Wireless Syringe Infusion Pump 2026-06-17 5.0 MEDIUM 5.3 MEDIUM
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.