Total
402515 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-9658 | 1 Philips | 2 Intellivue Mx40, Intellivue Mx40 Firmware | 2026-06-17 | 6.1 MEDIUM | 6.5 MEDIUM |
| Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point. | |||||
| CVE-2017-9657 | 1 Philips | 2 Intellivue Mx40, Intellivue Mx40 Firmware | 2026-06-17 | 3.3 LOW | 6.5 MEDIUM |
| Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point. | |||||
| CVE-2017-9656 | 1 Philips | 1 Dosewise | 2026-06-17 | 6.5 MEDIUM | 9.1 CRITICAL |
| The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. | |||||
| CVE-2017-9655 | 1 Osisoft | 3 Pi Integrator For Business Analystics, Pi Integrator For Microsoft Azure, Pi Integrator For Sap Hana | 2026-06-17 | 3.5 LOW | 5.4 MEDIUM |
| A Cross-Site Scripting issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker may be able to upload a malicious script that attempts to redirect users to a malicious web site. | |||||
| CVE-2017-9654 | 1 Philips | 1 Dosewise | 2026-06-17 | 4.0 MEDIUM | 8.8 HIGH |
| The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N. | |||||
| CVE-2017-9653 | 1 Osisoft | 3 Pi Integrator For Business Analystics, Pi Integrator For Microsoft Azure, Pi Integrator For Sap Hana | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| An Improper Authorization issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker is able to gain privileged access to the system while unauthorized. | |||||
| CVE-2017-9650 | 2 Automatedlogic, Carrier | 3 I-vu, Sitescan Web, Automatedlogic Webctrl | 2026-06-17 | 4.6 MEDIUM | 7.8 HIGH |
| An Unrestricted Upload of File with Dangerous Type issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code. | |||||
| CVE-2017-9649 | 1 Mirion Technologies | 14 Dmc 3000, Dmc 3000 Firmware, Drm-1\/2 and 11 more | 2026-06-17 | 5.4 MEDIUM | 5.0 MEDIUM |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. | |||||
| CVE-2017-9648 | 1 Solarcontrols | 1 Wattconfig M | 2026-06-17 | 9.3 HIGH | 7.8 HIGH |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. | |||||
| CVE-2017-9647 | 1 Infineon | 1 S-gold 2 Pmb 8876 | 2026-06-17 | 7.2 HIGH | 6.6 MEDIUM |
| A Stack-Based Buffer Overflow issue was discovered in the Continental AG Infineon S-Gold 2 (PMB 8876) chipset on BMW several models produced between 2009-2010, Ford a limited number of P-HEV vehicles, Infiniti 2013 JX35, Infiniti 2014-2016 QX60, Infiniti 2014-2016 QX60 Hybrid, Infiniti 2014-2015 QX50, Infiniti 2014-2015 QX50 Hybrid, Infiniti 2013 M37/M56, Infiniti 2014-2016 Q70, Infiniti 2014-2016 Q70L, Infiniti 2015-2016 Q70 Hybrid, Infiniti 2013 QX56, Infiniti 2014-2016 QX 80, and Nissan 2011-2015 Leaf. An attacker with a physical connection to the TCU may exploit a buffer overflow condition that exists in the processing of AT commands. This may allow arbitrary code execution on the baseband radio processor of the TCU. | |||||
| CVE-2017-9646 | 1 Solarcontrols | 1 Heating Control Downloader | 2026-06-17 | 9.3 HIGH | 7.8 HIGH |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. | |||||
| CVE-2017-9645 | 1 Mirion | 16 Dmc 3000 Transmitter, Dmc 3000 Transmitter Firmware, Drm-1\/2 and 13 more | 2026-06-17 | 3.3 LOW | 6.5 MEDIUM |
| An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level. | |||||
| CVE-2017-9644 | 2 Automatedlogic, Carrier | 3 I-vu, Sitescan Web, Automatedlogic Webctrl | 2026-06-17 | 6.9 MEDIUM | 7.0 HIGH |
| An Unquoted Search Path or Element issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An unquoted search path vulnerability may allow a non-privileged local attacker to change files in the installation directory and execute arbitrary code with elevated privileges. | |||||
| CVE-2017-9641 | 1 Osisoft | 1 Pi Coresight | 2026-06-17 | 6.8 MEDIUM | 8.8 HIGH |
| PI Coresight 2016 R2 contains a cross-site request forgery vulnerability that may allow access to the PI system. OSIsoft recommends that users upgrade to PI Vision 2017 or greater to mitigate this vulnerability. | |||||
| CVE-2017-9640 | 2 Automatedlogic, Carrier | 3 I-vu, Sitescan Web, Automatedlogic Webctrl | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| A Path Traversal issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web prior to 6.5; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to overwrite files that are used to execute code. This vulnerability does not affect version 6.5 of the software. | |||||
| CVE-2017-9639 | 1 Fujielectric | 1 V-server | 2026-06-17 | 7.5 HIGH | 7.3 HIGH |
| An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution. | |||||
| CVE-2017-9638 | 1 Mitsubishielectric | 1 E-designer | 2026-06-17 | 10.0 HIGH | 9.8 CRITICAL |
| Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash. | |||||
| CVE-2017-9637 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2026-06-17 | 1.9 LOW | 4.1 MEDIUM |
| Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
| CVE-2017-9636 | 1 Mitsubishielectric | 1 E-designer | 2026-06-17 | 10.0 HIGH | 9.8 CRITICAL |
| Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash. | |||||
| CVE-2017-9635 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2026-06-17 | 1.9 LOW | 3.9 LOW |
| Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||