Total
413843 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-16235 | 1 Emerson | 1 Openenterprise Scada Server | 2026-06-17 | 2.1 LOW | 3.8 LOW |
| Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained. | |||||
| CVE-2020-16234 | 1 Fatek | 1 Winproladder | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code. | |||||
| CVE-2020-16233 | 1 Wibu | 1 Codemeter | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap. | |||||
| CVE-2020-16232 | 1 Yokogawa | 1 Widefield3 | 2026-06-17 | 7.5 HIGH | 2.8 LOW |
| In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file. | |||||
| CVE-2020-16231 | 1 Bachmann | 40 Cpc210, Cpc210 Firmware, Cs200 and 37 more | 2026-06-17 | 6.5 MEDIUM | 7.2 HIGH |
| The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. Affected controllers that are actively supported include MX207, MX213, MX220, MC206, MC212, MC220, and MH230 hardware controllers, and affected end-of-life controller include MC205, MC210, MH212, ME203, CS200, MP213, MP226, MPC240, MPC265, MPC270, MPC293, MPE270, and CPC210 hardware controllers. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticated person with physical access to the device reads and decrypts the password to conduct further attacks. | |||||
| CVE-2020-16230 | 1 Hms-networks | 4 Ewon Cosy, Ewon Cosy Firmware, Ewon Flexy and 1 more | 2026-06-17 | 2.1 LOW | 2.3 LOW |
| All version of Ewon Flexy and Cosy prior to 14.1 use wildcards such as (*) under which domains can request resources. An attacker with local access and high privileges could inject scripts into the Cross-origin Resource Sharing (CORS) configuration that could abuse this vulnerability, allowing the attacker to retrieve limited confidential information through sniffing. | |||||
| CVE-2020-16229 | 1 Advantech | 1 Webaccess\/hmi Designer | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash. | |||||
| CVE-2020-16228 | 1 Philips | 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more | 2026-06-17 | 5.2 MEDIUM | 6.4 MEDIUM |
| In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate. | |||||
| CVE-2020-16227 | 1 Deltaww | 1 Tpeditor | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Delta Electronics TPEditor Versions 1.97 and prior. An improper input validation may be exploited by processing a specially crafted project file not validated when the data is entered by a user. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. | |||||
| CVE-2020-16226 | 1 Mitsubishielectric | 186 Conveyor Tracking Application Apr-ntr12fh, Conveyor Tracking Application Apr-ntr20fh\(n\=1\,2\), Conveyor Tracking Application Apr-ntr3fh and 183 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. | |||||
| CVE-2020-16225 | 1 Deltaww | 1 Tpeditor | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Delta Electronics TPEditor Versions 1.97 and prior. A write-what-where condition may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. | |||||
| CVE-2020-16224 | 1 Philips | 1 Patient Information Center Ix | 2026-06-17 | 3.3 LOW | 6.5 MEDIUM |
| In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart. | |||||
| CVE-2020-16223 | 1 Deltaww | 1 Tpeditor | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Delta Electronics TPEditor Versions 1.97 and prior. A heap-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. | |||||
| CVE-2020-16222 | 1 Philips | 2 Patient Information Center Ix, Performancebridge Focal Point | 2026-06-17 | 5.8 MEDIUM | 8.8 HIGH |
| In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct. | |||||
| CVE-2020-16221 | 1 Deltaww | 1 Tpeditor | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Delta Electronics TPEditor Versions 1.97 and prior. A stack-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. | |||||
| CVE-2020-16220 | 1 Philips | 2 Patient Information Center Ix, Performancebridge Focal Point | 2026-06-17 | 3.3 LOW | 4.3 MEDIUM |
| In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling. | |||||
| CVE-2020-16219 | 1 Deltaww | 1 Tpeditor | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Delta Electronics TPEditor Versions 1.97 and prior. An out-of-bounds read may be exploited by processing specially crafted project files. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application. | |||||
| CVE-2020-16218 | 1 Philips | 1 Patient Information Center Ix | 2026-06-17 | 2.7 LOW | 3.5 LOW |
| In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application. | |||||
| CVE-2020-16217 | 1 Advantech | 1 Webaccess\/hmi Designer | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. A double free vulnerability caused by processing specially crafted project files may allow remote code execution, disclosure/modification of information, or cause the application to crash. | |||||
| CVE-2020-16216 | 1 Philips | 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more | 2026-06-17 | 6.1 MEDIUM | 6.5 MEDIUM |
| In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart. | |||||