Vulnerabilities (CVE)

Total 419090 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-22293 1 Huawei 4 Campusinsight, Manageone, Taurus-al00a and 1 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
Some Huawei products have an inconsistent interpretation of HTTP requests vulnerability. Attackers can exploit this vulnerability to cause information leak. Affected product versions include: CampusInsight versions V100R019C10; ManageOne versions 6.5.1.1, 6.5.1.SPC100, 6.5.1.SPC200, 6.5.1RC1, 6.5.1RC2, 8.0.RC2. Affected product versions include: Taurus-AL00A versions 10.0.0.1(C00E1R1P1).
CVE-2021-22292 1 Huawei 2 Ecns280, Ecns280 Firmware 2026-06-17 7.8 HIGH 7.5 HIGH
There is a denial of service (DoS) vulnerability in eCNS280 versions V100R005C00, V100R005C10. Due to a design defect, remote unauthorized attackers send a large number of specific messages to affected devices, causing system resource exhaustion and web application DoS.
CVE-2021-22291 2026-06-17 N/A 8.0 HIGH
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in ABB EIBPORT V3 KNX, ABB EIBPORT V3 KNX GSM.This issue affects EIBPORT V3 KNX: before 3.9.2; EIBPORT V3 KNX GSM: before 3.9.2.
CVE-2021-22289 1 Br-automation 1 Studio 2026-06-17 N/A 8.3 HIGH
Improper Input Validation vulnerability in the project upload mechanism in B&R Automation Studio version >=4.0 may allow an unauthenticated network attacker to execute code.
CVE-2021-22288 1 Abb 4 Pni800, Pni800 Firmware, Spiet800 and 1 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
CVE-2021-22286 1 Abb 4 Pni800, Pni800 Firmware, Spiet800 and 1 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
CVE-2021-22285 1 Abb 4 Pni800, Pni800 Firmware, Spiet800 and 1 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive.
CVE-2021-22284 1 Abb 1 Opc Server For Ac 800m 2026-06-17 6.5 MEDIUM 8.4 HIGH
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.
CVE-2021-22283 1 Abb 38 Evd4, Evd4 Firmware, Rec615 and 35 more 2026-06-17 N/A 6.2 MEDIUM
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
CVE-2021-22282 1 Br-automation 1 Automation Studio 2026-06-17 N/A 8.3 HIGH
Improper Control of Generation of Code ('Code Injection') vulnerability in B&R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12.
CVE-2021-22281 1 Br-automation 1 Automation Studio 2026-06-17 N/A 6.3 MEDIUM
: Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12.
CVE-2021-22280 1 Br-automation 1 Automation Studio 2026-06-17 N/A 7.2 HIGH
Improper DLL loading algorithms in B&R Automation Studio versions >=4.0 and <4.12 may allow an authenticated local attacker to execute code in the context of the product.
CVE-2021-22279 1 Abb 2 Omnicore C30, Omnicore C30 Firmware 2026-06-17 9.3 HIGH 9.8 CRITICAL
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
CVE-2021-22278 2 Abb, Hitachienergy 2 Update Manager, Pcm600 2026-06-17 4.6 MEDIUM 6.7 MEDIUM
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.
CVE-2021-22277 1 Abb 4 800xa, Base Software, Compact Product Suite and 1 more 2026-06-17 7.8 HIGH 7.5 HIGH
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
CVE-2021-22276 1 Abb 10 System Access Point 127v, System Access Point 127v Firmware, System Access Point 2.0 and 7 more 2026-06-17 4.3 MEDIUM 6.1 MEDIUM
The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point.
CVE-2021-22275 1 Br-automation 1 Automation Runtime 2026-06-17 7.8 HIGH 8.6 HIGH
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service.
CVE-2021-22272 2 Abb, Busch-jaeger 2 Mybuildings, Mybusch-jaeger 2026-06-17 9.0 HIGH 6.5 MEDIUM
The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch
CVE-2021-22267 1 Hpe 2 Nonstop, Web Viewpoint 2026-06-17 4.3 MEDIUM 5.9 MEDIUM
Idelji Web ViewPoint Suite, as used in conjunction with HPE NonStop, allows a remote replay attack for T0320L01^ABP through T0320L01^ABZ, T0952L01^AAH through T0952L01^AAR, T0986L01 through T0986L01^AAF, T0665L01^AAP, and T0662L01^AAP (L) and T0320H01^ABO through T0320H01^ABY, T0952H01^AAG through T0952H01^AAQ, T0986H01 through T0986H01^AAE, T0665H01^AAO, and T0662H01^AAO (J and H).
CVE-2021-22264 1 Gitlab 1 Gitlab 2026-06-17 4.3 MEDIUM 6.8 MEDIUM
An issue has been discovered in GitLab affecting all versions starting from 13.8 before 14.0.9, all versions starting from 14.1 before 14.1.4, all versions starting from 14.2 before 14.2.2. Under specialized conditions, an invited group member may continue to have access to a project even after the invited group, which the member was part of, is deleted.