Vulnerabilities (CVE)

Total 420464 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-31352 1 Juniper 1 Session And Resource Control 2026-06-17 5.0 MEDIUM 5.3 MEDIUM
An Information Exposure vulnerability in Juniper Networks SRC Series devices configured for NETCONF over SSH permits the negotiation of weak ciphers, which could allow a remote attacker to obtain sensitive information. A remote attacker with read and write access to network data could exploit this vulnerability to display plaintext bits from a block of ciphertext and obtain sensitive information. This issue affects all Juniper Networks SRC Series versions prior to 4.13.0-R6.
CVE-2021-31351 1 Juniper 18 Junos, Mx10, Mx10000 and 15 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions in packet processing on the MS-MPC/MS-MIC utilized by Juniper Networks Junos OS allows a malicious attacker to send a specific packet, triggering the MS-MPC/MS-MIC to reset, causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects specific versions of Juniper Networks Junos OS on MX Series: 17.3R3-S11; 17.4R2-S13; 17.4R3 prior to 17.4R3-S5; 18.1R3-S12; 18.2R2-S8, 18.2R3-S7, 18.2R3-S8; 18.3R3-S4; 18.4R3-S7; 19.1R3-S4, 19.1R3-S5; 19.2R1-S6; 19.3R3-S2; 19.4R2-S4, 19.4R2-S5; 19.4R3-S2; 20.1R2-S1; 20.2R2-S2, 20.2R2-S3, 20.2R3; 20.3R2, 20.3R2-S1; 20.4R1, 20.4R1-S1, 20.4R2; 21.1R1; This issue does not affect any version of Juniper Networks Junos OS prior to 15.1X49-D240;
CVE-2021-31350 1 Juniper 2 Junos, Junos Os Evolved 2026-06-17 9.0 HIGH 7.5 HIGH
An Improper Privilege Management vulnerability in the gRPC framework, used by the Juniper Extension Toolkit (JET) API on Juniper Networks Junos OS and Junos OS Evolved, allows a network-based, low-privileged authenticated attacker to perform operations as root, leading to complete compromise of the targeted system. The issue is caused by the JET service daemon (jsd) process authenticating the user, then passing configuration operations directly to the management daemon (mgd) process, which runs as root. This issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R1-S8, 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R2-S3, 19.1R3-S5; 19.2 versions prior to 19.2R1-S7, 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S3; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2-S1, 20.3R3; 20.4 versions prior to 20.4R2. This issue does not affect Juniper Networks Junos OS versions prior to 18.4R1. Juniper Networks Junos OS Evolved: All versions prior to 20.4R2-EVO; 21.1-EVO versions prior to 21.1R2-EVO.
CVE-2021-31349 1 Juniper 2 128 Technology Session Smart Router, 128 Technology Session Smart Router Firmware 2026-06-17 7.5 HIGH 9.8 CRITICAL
The usage of an internal HTTP header created an authentication bypass vulnerability (CWE-287), allowing an attacker to view internal files, change settings, manipulate services and execute arbitrary code. This issue affects all Juniper Networks 128 Technology Session Smart Router versions prior to 4.5.11, and all versions of 5.0 up to and including 5.0.1.
CVE-2021-31348 2 Debian, Ezxml Project 2 Debian Linux, Ezxml 2026-06-17 4.3 MEDIUM 6.5 MEDIUM
An issue was discovered in libezxml.a in ezXML 0.8.6. The function ezxml_parse_str() performs incorrect memory handling while parsing crafted XML files (out-of-bounds read after a certain strcspn failure).
CVE-2021-31347 2 Debian, Ezxml Project 2 Debian Linux, Ezxml 2026-06-17 4.3 MEDIUM 6.5 MEDIUM
An issue was discovered in libezxml.a in ezXML 0.8.6. The function ezxml_parse_str() performs incorrect memory handling while parsing crafted XML files (writing outside a memory region created by mmap).
CVE-2021-31346 1 Siemens 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more 2026-06-17 6.4 MEDIUM 8.2 HIGH
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
CVE-2021-31345 1 Siemens 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more 2026-06-17 6.4 MEDIUM 7.5 HIGH
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
CVE-2021-31344 1 Siemens 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more 2026-06-17 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)
CVE-2021-31343 1 Siemens 4 Solid Edge Se2020, Solid Edge Se2020 Firmware, Solid Edge Se2021 and 1 more 2026-06-17 6.8 MEDIUM 8.8 HIGH
The jutil.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocation structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-31342 1 Siemens 4 Solid Edge Se2020, Solid Edge Se2020 Firmware, Solid Edge Se2021 and 1 more 2026-06-17 6.8 MEDIUM 8.8 HIGH
The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-31341 1 Mendix 1 Database Replication 2026-06-17 4.0 MEDIUM 4.3 MEDIUM
Uploading a table mapping using a manipulated XML file results in an exception that could expose information about the application-server and the used XML-framework on the Mendix Database Replication Module (All versions prior to v7.0.1).
CVE-2021-31340 1 Siemens 50 Simatic Reader Rf610r Cmiit, Simatic Reader Rf610r Cmiit Firmware, Simatic Reader Rf610r Etsi and 47 more 2026-06-17 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.
CVE-2021-31339 1 Mendix 1 Excel Importer 2026-06-17 4.0 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in Mendix Excel Importer Module (All versions < V9.0.3). Uploading a manipulated XML File results in an exception that could expose information about the Application-Server and the used XML-Framework.
CVE-2021-31338 1 Siemens 1 Sinema Remote Connect 2026-06-17 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device.
CVE-2021-31337 1 Siemens 6 Sinamics Sl150, Sinamics Sl150 Firmware, Sinamics Sm150 and 3 more 2026-06-17 6.8 MEDIUM 9.8 CRITICAL
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
CVE-2021-31330 1 Reviewboard 1 Review Board 2026-06-17 3.5 LOW 5.4 MEDIUM
A Cross-Site Scripting (XSS) vulnerability exists within Review Board versions 3.0.20 and 4.0 RC1 and earlier. An authenticated attacker may inject malicious Javascript code when using Markdown editing within the application which remains persistent.
CVE-2021-31329 1 Remoteclinic 1 Remote Clinic 2026-06-17 3.5 LOW 5.4 MEDIUM
Cross Site Scripting (XSS) in Remote Clinic v2.0 via the "Chat" and "Personal Address" field on staff/register.php
CVE-2021-31327 1 Remoteclinic 1 Remote Clinic 2026-06-17 3.5 LOW 5.4 MEDIUM
Stored XSS in Remote Clinic v2.0 in /medicines due to Medicine Name Field.
CVE-2021-31326 1 Dlink 2 Dir-816, Dir-816 Firmware 2026-06-17 9.0 HIGH 9.8 CRITICAL
D-Link DIR-816 A2 1.10 B05 allows unauthenticated attackers to arbitrarily reset the device via a crafted tokenid parameter to /goform/form2Reboot.cgi.