Vulnerabilities (CVE)

Total 424170 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-26420 1 Inhandnetworks 2 Ir302, Ir302 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
An OS command injection vulnerability exists in the console infactory_port functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
CVE-2022-26419 1 Omron 1 Cx-position 2026-06-17 6.8 MEDIUM 7.8 HIGH
Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.
CVE-2022-26417 1 Omron 1 Cx-position 2026-06-17 6.8 MEDIUM 7.8 HIGH
Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code.
CVE-2022-26415 1 F5 11 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 8 more 2026-06-17 6.0 MEDIUM 7.7 HIGH
On F5 BIG-IP 16.1.x versions prior to 16.1.2.2, 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, 13.1.x versions prior to 13.1.5, and all versions of 12.1.x, when running in Appliance mode, an authenticated user assigned the Administrator role may be able to bypass Appliance mode restrictions, utilizing an undisclosed iControl REST endpoint. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CVE-2022-26414 1 Zyxel 64 Ax7501-b0, Ax7501-b0 Firmware, Dx5401-b0 and 61 more 2026-06-17 4.9 MEDIUM 6.0 MEDIUM
A potential buffer overflow vulnerability was identified in some internal functions of Zyxel VMG3312-T20A firmware version 5.30(ABFX.5)C0, which could be exploited by a local authenticated attacker to cause a denial of service.
CVE-2022-26413 1 Zyxel 64 Ax7501-b0, Ax7501-b0 Firmware, Dx5401-b0 and 61 more 2026-06-17 7.7 HIGH 8.0 HIGH
A command injection vulnerability in the CGI program of Zyxel VMG3312-T20A firmware version 5.30(ABFX.5)C0 could allow a local authenticated attacker to execute arbitrary OS commands on a vulnerable device via a LAN interface.
CVE-2022-26394 1 Baxter 8 Baxter Spectrum Iq 35700bax3, Baxter Spectrum Iq 35700bax3 Firmware, Sigma Spectrum 35700bax and 5 more 2026-06-17 N/A 5.5 MEDIUM
The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middle attack that modifies parameters making the network connection fail.
CVE-2022-26393 1 Baxter 8 Baxter Spectrum Iq 35700bax3, Baxter Spectrum Iq 35700bax3 Firmware, Sigma Spectrum 35700bax and 5 more 2026-06-17 N/A 5.0 MEDIUM
The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a Denial of Service (DoS) on the WBM.
CVE-2022-26392 1 Baxter 8 Baxter Spectrum Iq 35700bax3, Baxter Spectrum Iq 35700bax3 Firmware, Sigma Spectrum 35700bax and 5 more 2026-06-17 N/A 3.1 LOW
The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information.
CVE-2022-26390 1 Baxter 8 Baxter Spectrum Iq 35700bax3, Baxter Spectrum Iq 35700bax3 Firmware, Sigma Spectrum 35700bax and 5 more 2026-06-17 N/A 4.2 MEDIUM
The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive information.
CVE-2022-26389 2026-06-17 N/A 7.7 HIGH
An improper access control vulnerability may allow privilege escalation.This issue affects:  * ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior;  * ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior;  * ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior;  * ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.
CVE-2022-26388 2026-06-17 N/A 6.4 MEDIUM
A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.
CVE-2022-26387 1 Mozilla 3 Firefox, Firefox Esr, Thunderbird 2026-06-17 N/A 7.5 HIGH
When installing an add-on, Firefox verified the signature before prompting the user; but while the user was confirming the prompt, the underlying add-on file could have been modified and Firefox would not have noticed. This vulnerability affects Firefox < 98, Firefox ESR < 91.7, and Thunderbird < 91.7.
CVE-2022-26386 3 Apple, Linux, Mozilla 4 Macos, Linux Kernel, Firefox Esr and 1 more 2026-06-17 N/A 6.5 MEDIUM
Previously Firefox for macOS and Linux would download temporary files to a user-specific directory in <code>/tmp</code>, but this behavior was changed to download them to <code>/tmp</code> where they could be affected by other local users. This behavior was reverted to the original, user-specific directory. <br>*This bug only affects Firefox for macOS and Linux. Other operating systems are unaffected.*. This vulnerability affects Firefox ESR < 91.7 and Thunderbird < 91.7.
CVE-2022-26385 1 Mozilla 1 Firefox 2026-06-17 N/A 6.5 MEDIUM
In unusual circumstances, an individual thread may outlive the thread's manager during shutdown. This could have led to a use-after-free causing a potentially exploitable crash. This vulnerability affects Firefox < 98.
CVE-2022-26384 1 Mozilla 3 Firefox, Firefox Esr, Thunderbird 2026-06-17 N/A 9.6 CRITICAL
If an attacker could control the contents of an iframe sandboxed with <code>allow-popups</code> but not <code>allow-scripts</code>, they were able to craft a link that, when clicked, would lead to JavaScript execution in violation of the sandbox. This vulnerability affects Firefox < 98, Firefox ESR < 91.7, and Thunderbird < 91.7.
CVE-2022-26383 1 Mozilla 3 Firefox, Firefox Esr, Thunderbird 2026-06-17 N/A 4.3 MEDIUM
When resizing a popup after requesting fullscreen access, the popup would not display the fullscreen notification. This vulnerability affects Firefox < 98, Firefox ESR < 91.7, and Thunderbird < 91.7.
CVE-2022-26382 1 Mozilla 1 Firefox 2026-06-17 N/A 4.3 MEDIUM
While the text displayed in Autofill tooltips cannot be directly read by JavaScript, the text was rendered using page fonts. Side-channel attacks on the text by using specially crafted fonts could have lead to this text being inferred by the webpage. This vulnerability affects Firefox < 98.
CVE-2022-26381 1 Mozilla 3 Firefox, Firefox Esr, Thunderbird 2026-06-17 N/A 8.8 HIGH
An attacker could have caused a use-after-free by forcing a text reflow in an SVG object leading to a potentially exploitable crash. This vulnerability affects Firefox < 98, Firefox ESR < 91.7, and Thunderbird < 91.7.
CVE-2022-26380 1 Siemens 48 Scalance X302-7eec, Scalance X302-7eec Firmware, Scalance X304-2fe and 45 more 2026-06-17 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.