Total
424869 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-33205 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 9.9 CRITICAL |
| Four OS command injection vulnerabilities exists in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability focuses on the unsafe use of the `wpapsk_hex` HTTP parameter to construct an OS Command at offset `0x19b0ac` of the `/root/hpgw` binary included in firmware 6.9Z. | |||||
| CVE-2022-33204 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 9.9 CRITICAL |
| Four OS command injection vulnerabilities exists in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability focuses on the unsafe use of the `ssid_hex` HTTP parameter to construct an OS Command at offset `0x19afc0` of the `/root/hpgw` binary included in firmware 6.9Z. | |||||
| CVE-2022-33203 | 1 F5 | 2 Big-ip Access Policy Manager, Big-ip Ssl Orchestrator | 2026-06-17 | N/A | 7.5 HIGH |
| In BIG-IP Versions 16.1.x before 16.1.3, 15.1.x before 15.1.6.1, and 14.1.x before 14.1.5, when a BIG-IP APM access policy with Service Connect agent is configured on a virtual server, undisclosed requests can cause an increase in memory resource utilization. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated. | |||||
| CVE-2022-33202 | 1 Softcreate | 1 L2blocker | 2026-06-17 | 4.8 MEDIUM | 8.1 HIGH |
| Authentication bypass vulnerability in the setup screen of L2Blocker(on-premise) Ver4.8.5 and earlier and L2Blocker(Cloud) Ver4.8.5 and earlier allows an adjacent attacker to perform an unauthorized login and obtain the stored information or cause a malfunction of the device by using alternative paths or channels for Sensor. | |||||
| CVE-2022-33201 | 1 Mailerlite | 1 Mailerlite Signup Forms | 2026-06-17 | N/A | 6.3 MEDIUM |
| Cross-Site Request Forgery (CSRF) vulnerability in MailerLite – Signup forms (official) plugin <= 1.5.7 at WordPress allows an attacker to change the API key. | |||||
| CVE-2022-33198 | 1 Oxilab | 1 Accordions | 2026-06-17 | N/A | 9.8 CRITICAL |
| Unauthenticated WordPress Options Change vulnerability in Biplob Adhikari's Accordions plugin <= 2.0.2 at WordPress. | |||||
| CVE-2022-33196 | 1 Intel | 272 Xeon D-1513n, Xeon D-1513n Firmware, Xeon D-1518 and 269 more | 2026-06-17 | N/A | 7.2 HIGH |
| Incorrect default permissions in some memory controller configurations for some Intel(R) Xeon(R) Processors when using Intel(R) Software Guard Extensions which may allow a privileged user to potentially enable escalation of privilege via local access. | |||||
| CVE-2022-33195 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 10.0 CRITICAL |
| Four OS command injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A XCMD can lead to arbitrary command execution. An attacker can send a sequence of malicious commands to trigger these vulnerabilities.This vulnerability focuses on the unsafe use of the `WL_DefaultKeyID` in the function located at offset `0x1c7d28` of firmware 6.9Z, and even more specifically on the command execution occuring at offset `0x1c7fac`. | |||||
| CVE-2022-33194 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 10.0 CRITICAL |
| Four OS command injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A XCMD can lead to arbitrary command execution. An attacker can send a sequence of malicious commands to trigger these vulnerabilities.This vulnerability focuses on the unsafe use of the `WL_Key` and `WL_DefaultKeyID` configuration values in the function located at offset `0x1c7d28` of firmware 6.9Z , and even more specifically on the command execution occuring at offset `0x1c7f6c`. | |||||
| CVE-2022-33193 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 10.0 CRITICAL |
| Four OS command injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A XCMD can lead to arbitrary command execution. An attacker can send a sequence of malicious commands to trigger these vulnerabilities.This vulnerability specifically focuses on the unsafe use of the `WL_WPAPSK` configuration value in the function located at offset `0x1c7d28` of firmware 6.9Z. | |||||
| CVE-2022-33192 | 1 Goabode | 1 Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 10.0 CRITICAL |
| Four OS command injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A XCMD can lead to arbitrary command execution. An attacker can send a sequence of malicious commands to trigger these vulnerabilities.This vulnerability specifically focuses on the unsafe use of the `WL_SSID` and `WL_SSID_HEX` configuration values in the function at offset `0x1c7d28` of firmware 6.9Z. | |||||
| CVE-2022-33191 | 1 Testimonials Project | 1 Testimonials | 2026-06-17 | N/A | 4.1 MEDIUM |
| Authenticated (contributor or higher user role) Stored Cross-Site Scripting (XSS) vulnerability in Chinmoy Paul's Testimonials plugin <= 3.0.1 at WordPress. | |||||
| CVE-2022-33190 | 1 Intel | 1 System Usage Report | 2026-06-17 | N/A | 7.1 HIGH |
| Improper input validation in the Intel(R) SUR software before version 2.4.8902 may allow an authenticated user to potentially enable escalation of privilege via local access. | |||||
| CVE-2022-33189 | 1 Goabode | 2 Iota All-in-one Security Kit, Iota All-in-one Security Kit Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| An OS command injection vulnerability exists in the XCMD setAlexa functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. A specially-crafted XCMD can lead to arbitrary command execution. An attacker can send a malicious XML payload to trigger this vulnerability. | |||||
| CVE-2022-33187 | 1 Broadcom | 1 Brocade Sannav | 2026-06-17 | N/A | 5.5 MEDIUM |
| Brocade SANnav before v2.2.1 logs usernames and encoded passwords in debug-enabled logs. The vulnerability could allow an attacker with admin privilege to read sensitive information. | |||||
| CVE-2022-33185 | 1 Broadcom | 1 Fabric Operating System | 2026-06-17 | N/A | 7.8 HIGH |
| Several commands in Brocade Fabric OS before Brocade Fabric OS v.9.0.1e, and v9.1.0 use unsafe string functions to process user input. Authenticated local attackers could abuse these vulnerabilities to exploit stack-based buffer overflows, allowing arbitrary code execution as the root user account. | |||||
| CVE-2022-33184 | 1 Broadcom | 1 Fabric Operating System | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability in fab_seg.c.h libraries of all Brocade Fabric OS versions before Brocade Fabric OS v9.1.1, v9.0.1e, v8.2.3c, v8.2.0_cbn5, 7.4.2j could allow local authenticated attackers to exploit stack-based buffer overflows and execute arbitrary code as the root user account. | |||||
| CVE-2022-33183 | 1 Broadcom | 1 Fabric Operating System | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability in Brocade Fabric OS CLI before Brocade Fabric OS v9.1.0, 9.0.1e, 8.2.3c, 8.2.0cbn5, 7.4.2.j could allow a remote authenticated attacker to perform stack buffer overflow using in “firmwaredownload” and “diagshow” commands. | |||||
| CVE-2022-33182 | 1 Broadcom | 1 Fabric Operating System | 2026-06-17 | N/A | 7.8 HIGH |
| A privilege escalation vulnerability in Brocade Fabric OS CLI before Brocade Fabric OS v9.1.0, 9.0.1e, 8.2.3c, 8.2.0cbn5, could allow a local authenticated user to escalate its privilege to root using switch commands “supportlink”, “firmwaredownload”, “portcfgupload, license, and “fosexec”. | |||||
| CVE-2022-33181 | 1 Broadcom | 1 Fabric Operating System | 2026-06-17 | N/A | 5.5 MEDIUM |
| An information disclosure vulnerability in Brocade Fabric OS CLI before Brocade Fabric OS v9.1.0, 9.0.1e, 8.2.3c, 8.2.0cbn5, 7.4.2.j could allow a local authenticated attacker to read sensitive files using switch commands “configshow” and “supportlink”. | |||||
