Vulnerabilities (CVE)

Total 422082 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-27995 1 Fortinet 1 Fortisoar 2026-06-17 N/A 7.2 HIGH
A improper neutralization of special elements used in a template engine vulnerability in Fortinet FortiSOAR 7.3.0 through 7.3.1 allows an authenticated, remote attacker to execute arbitrary code via a crafted payload.
CVE-2023-27993 1 Fortinet 1 Fortiadc 2026-06-17 N/A 6.0 MEDIUM
A relative path traversal [CWE-23] in Fortinet FortiADC version 7.2.0 and before 7.1.1 allows a privileged attacker to delete arbitrary directories from the underlying file system via crafted CLI commands.
CVE-2023-27992 1 Zyxel 6 Nas326, Nas326 Firmware, Nas540 and 3 more 2026-06-17 N/A 9.8 CRITICAL
The pre-authentication command injection vulnerability in the Zyxel NAS326 firmware versions prior to V5.21(AAZF.14)C0, NAS540 firmware versions prior to V5.21(AATB.11)C0, and NAS542 firmware versions prior to V5.21(ABAG.11)C0 could allow an unauthenticated attacker to execute some operating system (OS) commands remotely by sending a crafted HTTP request.
CVE-2023-27991 1 Zyxel 38 Atp100, Atp100 Firmware, Atp100w and 35 more 2026-06-17 N/A 8.8 HIGH
The post-authentication command injection vulnerability in the CLI command of Zyxel ATP series firmware versions 4.32 through 5.35, USG FLEX series firmware versions 4.50 through 5.35, USG FLEX 50(W) firmware versions 4.16 through 5.35, USG20(W)-VPN firmware versions 4.16 through 5.35, and VPN series firmware versions 4.30 through 5.35, which could allow an authenticated attacker to execute some OS commands remotely.
CVE-2023-27990 1 Zyxel 38 Atp100, Atp100 Firmware, Atp100w and 35 more 2026-06-17 N/A 4.8 MEDIUM
The cross-site scripting (XSS) vulnerability in Zyxel ATP series firmware versions 4.32 through 5.35, USG FLEX series firmware versions 4.50 through 5.35, USG FLEX 50(W) firmware versions 4.16 through 5.35, USG20(W)-VPN firmware versions 4.16 through 5.35, and VPN series firmware versions 4.30 through 5.35, which could allow an authenticated attacker with administrator privileges to store malicious scripts in a vulnerable device. A successful XSS attack could then result in the stored malicious scripts being executed when the user visits the Logs page of the GUI on the device.
CVE-2023-27989 1 Zyxel 8 Lte7480-m804, Lte7480-m804 Firmware, Lte7490-m904 and 5 more 2026-06-17 N/A 6.5 MEDIUM
A buffer overflow vulnerability in the CGI program of the Zyxel NR7101 firmware versions prior to V1.00(ABUV.8)C0 could allow a remote authenticated attacker to cause denial of service (DoS) conditions by sending a crafted HTTP request to a vulnerable device.
CVE-2023-27988 1 Zyxel 6 Nas326, Nas326 Firmware, Nas540 and 3 more 2026-06-17 N/A 7.2 HIGH
The post-authentication command injection vulnerability in the Zyxel NAS326 firmware versions prior to V5.21(AAZF.13)C0 could allow an authenticated attacker with administrator privileges to execute some operating system (OS) commands on an affected device remotely.
CVE-2023-27987 1 Apache 1 Linkis 2026-06-17 N/A 9.1 CRITICAL
In Apache Linkis <=1.3.1, due to the default token generated by Linkis Gateway deployment being too simple, it is easy for attackers to obtain the default token for the attack. Generation rules should add random values. We recommend users upgrade the version of Linkis to version 1.3.2 And modify the default token value. You can refer to Token authorization[1] https://linkis.apache.org/docs/latest/auth/token https://linkis.apache.org/docs/latest/auth/token
CVE-2023-27986 1 Gnu 1 Emacs 2026-06-17 N/A 7.8 HIGH
emacsclient-mail.desktop in Emacs 28.1 through 28.2 is vulnerable to Emacs Lisp code injections through a crafted mailto: URI with unescaped double-quote characters. It is fixed in 29.0.90.
CVE-2023-27985 1 Gnu 1 Emacs 2026-06-17 N/A 7.8 HIGH
emacsclient-mail.desktop in Emacs 28.1 through 28.2 is vulnerable to shell command injections through a crafted mailto: URI. This is related to lack of compliance with the Desktop Entry Specification. It is fixed in 29.0.90
CVE-2023-27984 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 7.8 HIGH
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27983 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 6.5 MEDIUM
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27982 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 8.8 HIGH
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27981 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 7.8 HIGH
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27980 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 8.8 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
CVE-2023-27979 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27978 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 7.8 HIGH
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27977 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2026-06-17 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27976 1 Schneider-electric 1 Ecostruxure Control Expert 2026-06-17 N/A 8.8 HIGH
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
CVE-2023-27975 1 Schneider-electric 2 Ecostruxure Control Expert, Ecostruxure Process Expert 2026-06-17 N/A 7.1 HIGH
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.