Total
421267 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-31182 | 1 Easytor | 1 Easytor | 2026-06-17 | N/A | 8.1 HIGH |
| EasyTor Applications – Authorization Bypass - EasyTor Applications may allow authorization bypass via unspecified method. | |||||
| CVE-2023-31181 | 1 Wjjsoft | 1 Innokb | 2026-06-17 | N/A | 7.5 HIGH |
| WJJ Software - InnoKB Server, InnoKB/Console 2.2.1 - CWE-22: Path Traversal | |||||
| CVE-2023-31180 | 1 Wjjsoft | 1 Innokb | 2026-06-17 | N/A | 6.1 MEDIUM |
| WJJ Software - InnoKB Server, InnoKB/Console 2.2.1 - Reflected cross-site scripting (RXSS) through an unspecified request. | |||||
| CVE-2023-31179 | 1 Agilepoint | 1 Agilepoint Nx | 2026-06-17 | N/A | 6.5 MEDIUM |
| AgilePoint NX v8.0 SU2.2 & SU2.3 - Path traversal - Vulnerability allows path traversal and downloading files from the server, by an unspecified request. | |||||
| CVE-2023-31178 | 1 Agilepoint | 1 Agilepoint Nx | 2026-06-17 | N/A | 8.1 HIGH |
| AgilePoint NX v8.0 SU2.2 & SU2.3 – Arbitrary File Delete Vulnerability allows arbitrary file deletion, by an unspecified request. | |||||
| CVE-2023-31177 | 1 Selinc | 2 Sel-451, Sel-451 Firmware | 2026-06-17 | N/A | 4.3 MEDIUM |
| An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for more details. | |||||
| CVE-2023-31176 | 1 Selinc | 2 Sel-451, Sel-451 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details. | |||||
| CVE-2023-31175 | 1 Selinc | 1 Sel-5037 Sel Grid Configurator | 2026-06-17 | N/A | 8.8 HIGH |
| An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. | |||||
| CVE-2023-31174 | 1 Selinc | 1 Sel-5037 Sel Grid Configurator | 2026-06-17 | N/A | 7.4 HIGH |
| A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. | |||||
| CVE-2023-31173 | 2 Microsoft, Selinc | 2 Windows, Sel-5037 Sel Grid Configurator | 2026-06-17 | N/A | 7.7 HIGH |
| Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. | |||||
| CVE-2023-31172 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2026-06-17 | N/A | 5.9 MEDIUM |
| An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | |||||
| CVE-2023-31171 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2026-06-17 | N/A | 5.9 MEDIUM |
| An Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | |||||
| CVE-2023-31170 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2026-06-17 | N/A | 5.9 MEDIUM |
| An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | |||||
| CVE-2023-31169 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2026-06-17 | N/A | 4.8 MEDIUM |
| An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | |||||
| CVE-2023-31168 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2026-06-17 | N/A | 5.5 MEDIUM |
| An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | |||||
| CVE-2023-31167 | 2 Microsoft, Selinc | 2 Windows, Sel-5036 Acselerator Bay Screen Builder | 2026-06-17 | N/A | 5.0 MEDIUM |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details. This issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778. | |||||
| CVE-2023-31166 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2026-06-17 | N/A | 4.1 MEDIUM |
| An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
| CVE-2023-31165 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2026-06-17 | N/A | 4.3 MEDIUM |
| An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
| CVE-2023-31164 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2026-06-17 | N/A | 4.3 MEDIUM |
| An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
| CVE-2023-31163 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2026-06-17 | N/A | 4.3 MEDIUM |
| An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | |||||
