Vulnerabilities (CVE)

Filtered by CWE-912
Total 88 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-16204 1 Redlion 4 N-tron 702-w, N-tron 702-w Firmware, N-tron 702m12-w and 1 more 2026-06-17 10.0 HIGH 9.8 CRITICAL
The affected product is vulnerable due to an undocumented interface found on the device, which may allow an attacker to execute commands as root on the device on the N-Tron 702-W / 702M12-W (all versions).
CVE-2020-14487 1 Freemedsoftware 1 Openclinic Ga 2026-06-17 7.5 HIGH 9.4 CRITICAL
OpenClinic GA 5.09.02 contains a hidden default user account that may be accessed if an administrator has not expressly turned off this account, which may allow an attacker to login and execute arbitrary commands.
CVE-2020-12504 3 Korenix, Pepperl-fuchs, Westermo 58 Jetwave 2212g, Jetwave 2212g Firmware, Jetwave 2212s and 55 more 2026-06-17 7.5 HIGH 9.8 CRITICAL
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) and ICRL-M-8RJ45/4SFP-G-DIN, ICRL-M-16RJ45/4CP-G-DIN FW 1.2.3 and below has an active TFTP-Service.
CVE-2018-17919 1 Xiongmaitech 1 Xmeye P2p Cloud Server 2026-06-17 6.4 MEDIUM 6.5 MEDIUM
All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use an undocumented user account "default" with its default password to login to XMeye and access/view video streams.
CVE-2017-20084 1 Jung-group 2 Smart Visu Server, Smart Visu Server Firmware 2026-06-17 4.6 MEDIUM 5.3 MEDIUM
A vulnerability has been found in JUNG Smart Visu Server 1.0.804/1.0.830/1.0.832 and classified as critical. Affected by this vulnerability is an unknown functionality of the component KNX Group Address. The manipulation leads to backdoor. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.900 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2017-20083 1 Jung-group 2 Smart Visu Server, Smart Visu Server Firmware 2026-06-17 7.2 HIGH 5.3 MEDIUM
A vulnerability, which was classified as critical, was found in JUNG Smart Visu Server 1.0.804/1.0.830/1.0.832. Affected is an unknown function of the component SSH Server. The manipulation leads to backdoor. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.900 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2017-20082 1 Jung-group 2 Smart Visu Server, Smart Visu Server Firmware 2026-06-17 4.9 MEDIUM 5.5 MEDIUM
A vulnerability, which was classified as problematic, has been found in JUNG Smart Visu Server 1.0.804/1.0.830/1.0.832. This issue affects some unknown processing. The manipulation leads to backdoor. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.900 is able to address this issue. It is recommended to upgrade the affected component.
CVE-2011-10018 1 Mybb 1 Mybb 2026-06-16 N/A 9.8 CRITICAL
myBB version 1.6.4 was distributed with an unauthorized backdoor embedded in the source code. The backdoor allowed remote attackers to execute arbitrary PHP code by injecting payloads into a specially crafted collapsed cookie. This vulnerability was introduced during packaging and was not part of the intended application logic. Exploitation requires no authentication and results in full compromise of the web server under the context of the web application.