Total
125 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-41894 | 1 Home-assistant | 1 Home-assistant | 2026-06-17 | N/A | 5.3 MEDIUM |
| Home assistant is an open source home automation. The assessment verified that webhooks available in the webhook component are triggerable via the `*.ui.nabu.casa` URL without authentication, even when the webhook is marked as Only accessible from the local network. This issue is facilitated by the SniTun proxy, which sets the source address to 127.0.0.1 on all requests sent to the public URL and forwarded to the local Home Assistant. This issue has been addressed in version 2023.9.0 and all users are advised to upgrade. There are no known workarounds for this vulnerability. | |||||
| CVE-2023-31115 | 1 Samsung | 4 Exynos 5123, Exynos 5123 Firmware, Exynos 5300 and 1 more | 2026-06-17 | N/A | 7.5 HIGH |
| An issue was discovered in the Shannon RCS component in Samsung Exynos Modem 5123 and 5300. Incorrect resource transfer between spheres can cause changes to the activation mode of RCS via a crafted application. | |||||
| CVE-2023-31114 | 1 Samsung | 4 Exynos 5123, Exynos 5123 Firmware, Exynos 5300 and 1 more | 2026-06-17 | N/A | 9.1 CRITICAL |
| An issue was discovered in the Shannon RCS component in Samsung Exynos Modem 5123 and 5300. Incorrect resource transfer between spheres can cause unintended querying of the SIM status via a crafted application. | |||||
| CVE-2023-22950 | 1 Tigergraph | 1 Tigergraph | 2026-06-17 | N/A | 6.5 MEDIUM |
| An issue was discovered in TigerGraph Enterprise Free Edition 3.x. Data loading jobs in gsql_server, created by any user with designer permissions, can read sensitive data from arbitrary locations. | |||||
| CVE-2022-4446 | 1 Corebos | 1 Corebos | 2026-06-17 | N/A | 9.8 CRITICAL |
| PHP Remote File Inclusion in GitHub repository tsolucio/corebos prior to 8.0. | |||||
| CVE-2022-46173 | 1 Elrond | 1 Elrond Go | 2026-06-17 | N/A | 7.2 HIGH |
| Elrond-GO is a go implementation for the Elrond Network protocol. Versions prior to 1.3.50 are subject to a processing issue where nodes are affected when trying to process a cross-shard relayed transaction with a smart contract deploy transaction data. The problem was a bad correlation between the transaction caches and the processing component. If the above-mentioned transaction was sent with more gas than required, the smart contract result (SCR transaction) that should have returned the leftover gas, would have been wrongly added to a cache that the processing unit did not consider. The node stopped notarizing metachain blocks. The fix was actually to extend the SCR transaction search in all other caches if it wasn't found in the correct (expected) sharded-cache. There are no known workarounds at this time. This issue has been patched in version 1.3.50. | |||||
| CVE-2022-39225 | 1 Parseplatform | 1 Parse-server | 2026-06-17 | N/A | 4.3 MEDIUM |
| Parse Server is an open source backend that can be deployed to any infrastructure that can run Node.js. In versions prior to 4.10.15, or 5.0.0 and above prior to 5.2.6, a user can write to the session object of another user if the session object ID is known. For example, an attacker can assign the session object to their own user by writing to the `user` field and then read any custom fields of that session object. Note that assigning a session to another user does not usually change the privileges of either of the two users, and a user cannot assign their own session to another user. This issue is patched in version 4.10.15 and above, and 5.2.6 and above. To mitigate this issue in unpatched versions add a `beforeSave` trigger to the `_Session` class and prevent writing if the requesting user is different from the user in the session object. | |||||
| CVE-2022-35916 | 1 Openzeppelin | 2 Contracts, Contracts Upgradeable | 2026-06-17 | N/A | 5.3 MEDIUM |
| OpenZeppelin Contracts is a library for secure smart contract development. Contracts using the cross chain utilities for Arbitrum L2, `CrossChainEnabledArbitrumL2` or `LibArbitrumL2`, will classify direct interactions of externally owned accounts (EOAs) as cross chain calls, even though they are not started on L1. This issue has been patched in v4.7.2. Users are advised to upgrade. There are no known workarounds for this issue. | |||||
| CVE-2022-31233 | 1 Dell | 8 Evasa Provider Virtual Appliance, Powermax Os, Solutions Enabler and 5 more | 2026-06-17 | N/A | 6.3 MEDIUM |
| Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. | |||||
| CVE-2022-30236 | 1 Schneider-electric | 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more | 2026-06-17 | 6.4 MEDIUM | 8.2 HIGH |
| A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | |||||
| CVE-2022-20658 | 1 Cisco | 2 Unified Contact Center Express, Unified Contact Center Management Portal | 2026-06-17 | 8.5 HIGH | 9.6 CRITICAL |
| A vulnerability in the web-based management interface of Cisco Unified Contact Center Management Portal (Unified CCMP) and Cisco Unified Contact Center Domain Manager (Unified CCDM) could allow an authenticated, remote attacker to elevate their privileges to Administrator. This vulnerability is due to the lack of server-side validation of user permissions. An attacker could exploit this vulnerability by submitting a crafted HTTP request to a vulnerable system. A successful exploit could allow the attacker to create Administrator accounts. With these accounts, the attacker could access and modify telephony and user resources across all the Unified platforms that are associated to the vulnerable Cisco Unified CCMP. To successfully exploit this vulnerability, an attacker would need valid Advanced User credentials. | |||||
| CVE-2021-45891 | 1 Zauner | 1 Arc | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| An issue was discovered in Softwarebuero Zauner ARC 4.2.0.4., that allows attackers to escalate privileges within the application, since all permission checks are done client-side, not server-side. | |||||
| CVE-2021-34574 | 2 Helmholz, Mbconnectline | 4 Myrex24, Myrex24.virtual, Mbconnect24 and 1 more | 2026-06-17 | 4.0 MEDIUM | 4.3 MEDIUM |
| In MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server. | |||||
| CVE-2021-29960 | 1 Mozilla | 1 Firefox | 2026-06-17 | 4.3 MEDIUM | 4.3 MEDIUM |
| Firefox used to cache the last filename used for printing a file. When generating a filename for printing, Firefox usually suggests the web page title. The caching and suggestion techniques combined may have lead to the title of a website visited during private browsing mode being stored on disk. This vulnerability affects Firefox < 89. | |||||
| CVE-2021-25973 | 1 Publify Project | 1 Publify | 2026-06-17 | 6.4 MEDIUM | 6.5 MEDIUM |
| In Publify, 9.0.0.pre1 to 9.2.4 are vulnerable to Improper Access Control. “guest” role users can self-register even when the admin does not allow. This happens due to front-end restriction only. | |||||
| CVE-2021-24602 | 1 Hmplugin | 1 Hm Multiple Roles | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| The HM Multiple Roles WordPress plugin before 1.3 does not have any access control to prevent low privilege users to set themselves as admin via their profile page | |||||
| CVE-2021-22900 | 2 Ivanti, Pulsesecure | 2 Connect Secure, Pulse Connect Secure | 2026-06-17 | 6.5 MEDIUM | 7.2 HIGH |
| A vulnerability allowed multiple unrestricted uploads in Pulse Connect Secure before 9.1R11.4 that could lead to an authenticated administrator to perform a file write via a maliciously crafted archive upload in the administrator web interface. | |||||
| CVE-2021-22806 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior) | |||||
| CVE-2021-21531 | 1 Dell | 5 Powermax Os, Solutions Enabler, Solutions Enabler Virtual Appliance and 2 more | 2026-06-17 | 4.6 MEDIUM | 8.1 HIGH |
| Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions. | |||||
| CVE-2021-20411 | 2 Ibm, Linux | 2 Security Verify Information Queue, Linux Kernel | 2026-06-17 | 4.8 MEDIUM | 8.1 HIGH |
| IBM Security Verify Information Queue 1.0.6 and 1.0.7 could allow a user to impersonate another user on the system due to incorrectly updating the session identifier. IBM X-Force ID: 198191. | |||||