Vulnerabilities (CVE)

Filtered by CWE-312
Total 859 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-4537 1 Ruoyi 1 Ruoyi-vue 2026-06-17 2.6 LOW 3.1 LOW
A vulnerability was found in yangzongzhuan RuoYi-Vue up to 3.8.9 and classified as problematic. Affected by this issue is some unknown functionality of the file ruoyi-ui/jsencrypt.js and ruoyi-ui/login.vue of the component Password Handler. The manipulation leads to cleartext storage of sensitive information in a cookie. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-4394 2026-06-17 N/A 6.8 MEDIUM
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2025-4053 2026-06-17 N/A N/A
The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building. This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks.
CVE-2025-49728 1 Microsoft 1 Pc Manager 2026-06-17 N/A 4.0 MEDIUM
Cleartext storage of sensitive information in Microsoft PC Manager allows an unauthorized attacker to bypass a security feature locally.
CVE-2025-48463 1 Advantech 6 Wise-4010lan, Wise-4010lan Firmware, Wise-4050lan and 3 more 2026-06-17 N/A 3.1 LOW
Successful exploitation of the vulnerability could allow an attacker to intercept data and conduct session hijacking on the exposed data as the vulnerable product uses unencrypted HTTP communication, potentially leading to unauthorised access or data tampering.
CVE-2025-48428 2026-06-17 N/A 6.7 MEDIUM
Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site. This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior.
CVE-2025-47824 1 Flocksafety 1 License Plate Reader Firmware 2026-06-17 N/A 2.0 LOW
Flock Safety LPR (License Plate Reader) devices with firmware through 2.2 have cleartext storage of code.
CVE-2025-47820 1 Flocksafety 1 Gunshot Detection Firmware 2026-06-17 N/A 2.0 LOW
Flock Safety Gunshot Detection devices before 1.3 have cleartext storage of code.
CVE-2025-46820 2026-06-17 N/A 7.1 HIGH
phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue.
CVE-2025-46634 1 Tenda 2 Rx2 Pro, Rx2 Pro Firmware 2026-06-17 N/A 8.2 HIGH
Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an unauthenticated attacker to authenticate to the web management portal by collecting credentials from observed/collected traffic. It implements encryption, but not until after the user has transmitted the hash of their password in cleartext. The hash can be replayed to authenticate.
CVE-2025-46633 1 Tenda 2 Rx2 Pro, Rx2 Pro Firmware 2026-06-17 N/A 8.2 HIGH
Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 allows an attacker to decrypt traffic between the client and server by collecting the symmetric AES key from collected and/or observed traffic. The AES key in sent in cleartext in response to successful authentication. The IV is always EU5H62G9ICGRNI43.
CVE-2025-45001 1 Numan 1 React-native-keys 2026-06-17 N/A 7.5 HIGH
react-native-keys 0.7.11 is vulnerable to sensitive information disclosure (remote) as encryption cipher and Base64 chunks are stored as plaintext in the compiled native binary. Attackers can extract these secrets using basic static analysis tools.
CVE-2025-44614 1 Tinxy 2 Wifi Lock Controller V1 Rf, Wifi Lock Controller V1 Rf Firmware 2026-06-17 N/A 7.5 HIGH
Tinxy WiFi Lock Controller v1 RF was discovered to store users' sensitive information, including credentials and mobile phone numbers, in plaintext.
CVE-2025-41647 2026-06-17 N/A 5.5 MEDIUM
A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
CVE-2025-41458 2026-06-17 N/A 5.5 MEDIUM
Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct access to the app’s filesystem.
CVE-2025-40753 2026-06-17 N/A 6.2 MEDIUM
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-40752 2026-06-17 N/A 6.2 MEDIUM
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-3784 2026-06-17 N/A 5.5 MEDIUM
Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information.
CVE-2025-3442 2026-06-17 N/A N/A
This vulnerability exists in TP-Link Tapo H200 V1 IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device.
CVE-2025-3395 1 Abb 1 Automation Builder 2026-06-17 N/A 7.1 HIGH
Incorrect Permission Assignment for Critical Resource, Cleartext Storage of Sensitive Information vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.