Vulnerabilities (CVE)

Filtered by CWE-306
Total 3286 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-44216 1 Sir 1 Gnuboard 2026-06-17 N/A 7.5 HIGH
Gnuboard 5.5.4 and 5.5.5 is vulnerable to Insecure Permissions. An attacker can change password of all users without knowing victim's original password.
CVE-2022-44013 1 Simmeth 1 Lieferantenmanager 2026-06-17 N/A 9.1 CRITICAL
An issue was discovered in Simmeth Lieferantenmanager before 5.6. An attacker can make various API calls without authentication because the password in a Credential Object is not checked.
CVE-2022-44001 1 Backclick 1 Backclick 2026-06-17 N/A 9.8 CRITICAL
An issue was discovered in BACKCLICK Professional 5.9.63. User authentication for accessing the CORBA back-end services can be bypassed.
CVE-2022-44000 1 Backclick 1 Backclick 2026-06-17 N/A 9.8 CRITICAL
An issue was discovered in BACKCLICK Professional 5.9.63. Due to an exposed internal communications interface, it is possible to execute arbitrary system commands on the server.
CVE-2022-43999 1 Backclick 1 Backclick 2026-06-17 N/A 9.8 CRITICAL
An issue was discovered in BACKCLICK Professional 5.9.63. Due to exposed CORBA management services, arbitrary system commands can be executed on the server.
CVE-2022-43990 1 Sick 2 Sim1012-0p0g200, Sim1012-0p0g200 Firmware 2026-06-17 N/A 7.3 HIGH
Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal).
CVE-2022-43989 1 Sick 4 Sim2000-2p04g10, Sim2000-2p04g10 Firmware, Sim2500-2p03g10 and 1 more 2026-06-17 N/A 7.3 HIGH
Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal).
CVE-2022-43976 1 Ge 2 Ms 3000, Ms 3000 Firmware 2026-06-17 N/A 9.8 CRITICAL
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
CVE-2022-43761 1 Br-automation 1 Industrial Automation Aprol 2026-06-17 N/A 9.4 CRITICAL
Missing authentication when creating and managing the B&R APROL database in versions < R 4.2-07 allows reading and changing the system configuration. 
CVE-2022-43555 1 Ivanti 1 Avalanche 2026-06-17 N/A 7.8 HIGH
Ivanti Avalanche Printer Device Service Missing Authentication Local Privilege Escalation Vulnerability
CVE-2022-43554 1 Ivanti 1 Avalanche 2026-06-17 N/A 7.8 HIGH
Ivanti Avalanche Smart Device Service Missing Authentication Local Privilege Escalation Vulnerability
CVE-2022-43110 2026-06-17 N/A 9.8 CRITICAL
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
CVE-2022-42982 1 Bund 1 Bkg Professional Ntripcaster 2026-06-17 N/A 7.5 HIGH
BKG Professional NtripCaster 2.0.39 allows querying information over the UDP protocol without authentication. The NTRIP sourcetable is typically quite long (tens of kBs) and can be requested with a packet of only 30 bytes. This presents a vector that can be used for UDP amplification attacks. Normally, only authenticated streaming data will be provided over UDP and not the sourcetable.
CVE-2022-42970 2 Microsoft, Schneider-electric 8 Windows 10, Windows 11, Windows 7 and 5 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
CVE-2022-42785 1 Wut 34 At-modem-emulator, At-modem-emulator Firmware, Com-server 20ma and 31 more 2026-06-17 N/A 9.8 CRITICAL
Multiple W&T products of the ComServer Series are prone to an authentication bypass. An unathenticated remote attacker, can log in without knowledge of the password by crafting a modified HTTP GET Request.
CVE-2022-42473 1 Fortinet 1 Fortisoar 2026-06-17 N/A 5.3 MEDIUM
A missing authentication for a critical function vulnerability in Fortinet FortiSOAR 6.4.0 - 6.4.4 and 7.0.0 - 7.0.3 and 7.2.0 allows an attacker to disclose information via logging into the database using a privileged account without a password.
CVE-2022-42277 1 Nvidia 2 Dgx Station A100, Dgx Station A100 Firmware 2026-06-17 N/A 7.5 HIGH
NVIDIA DGX Station contains a vulnerability in SBIOS in the SmiFlash, where a local user with elevated privileges can read, write and erase flash, which may lead to code execution, escalation of privileges, denial of service, and information disclosure. The scope of impact can extend to other components.
CVE-2022-42276 1 Nvidia 2 Dgx A100, Dgx A100 Firmware 2026-06-17 N/A 7.5 HIGH
NVIDIA DGX A100 contains a vulnerability in SBIOS in the SmiFlash, where a local user with elevated privileges can read, write and erase flash, which may lead to code execution, escalation of privileges, denial of service, and information disclosure. The scope of impact can extend to other components.
CVE-2022-42275 1 Nvidia 2 Bmc, Dgx A100 2026-06-17 N/A 7.7 HIGH
NVIDIA BMC IPMI handler allows an unauthenticated host to write to a host SPI flash bypassing secureboot protections. This may lead to a loss of integrity and denial of service.
CVE-2022-41776 1 Deltaww 1 Infrasuite Device Master 2026-06-17 N/A 7.5 HIGH
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.