Total
7822 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-27673 | 1 Amd | 1 Amd Link | 2026-06-17 | N/A | 7.5 HIGH |
| Insufficient access controls in the AMD Link Android app may potentially result in information disclosure. | |||||
| CVE-2022-27660 | 1 Tcl | 1 Linkhub Mesh Wifi Ac1200 | 2026-06-17 | N/A | 7.5 HIGH |
| A denial of service vulnerability exists in the confctl_set_guest_wlan functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability. | |||||
| CVE-2022-27635 | 3 Debian, Fedoraproject, Intel | 17 Debian Linux, Fedora, Killer and 14 more | 2026-06-17 | N/A | 8.2 HIGH |
| Improper access control for some Intel(R) PROSet/Wireless WiFi and Killer(TM) WiFi software may allow a privileged user to potentially enable escalation of privilege via local access. | |||||
| CVE-2022-27511 | 1 Citrix | 1 Application Delivery Management | 2026-06-17 | 7.8 HIGH | 8.1 HIGH |
| Corruption of the system by a remote, unauthenticated user. The impact of this can include the reset of the administrator password at the next device reboot, allowing an attacker with ssh access to connect with the default administrator credentials after the device has rebooted. | |||||
| CVE-2022-27185 | 1 Tcl | 1 Linkhub Mesh Wifi Ac1200 | 2026-06-17 | N/A | 7.5 HIGH |
| A denial of service vulnerability exists in the confctl_set_master_wlan functionality of TCL LinkHub Mesh Wifi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability. | |||||
| CVE-2022-27178 | 1 Tcl | 1 Linkhub Mesh Wifi Ac1200 | 2026-06-17 | N/A | 9.8 CRITICAL |
| A denial of service vulnerability exists in the confctl_set_wan_cfg functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability. | |||||
| CVE-2022-26926 | 1 Microsoft | 10 Windows 10, Windows 11, Windows 7 and 7 more | 2026-06-17 | 6.8 MEDIUM | 7.8 HIGH |
| Windows Address Book Remote Code Execution Vulnerability | |||||
| CVE-2022-26423 | 1 Aethon | 1 Tug Home Base Server | 2026-06-17 | N/A | 8.2 HIGH |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. | |||||
| CVE-2022-26389 | 2026-06-17 | N/A | 7.7 HIGH | ||
| An improper access control vulnerability may allow privilege escalation.This issue affects: * ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; * ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; * ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; * ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior. | |||||
| CVE-2022-26346 | 1 Tcl | 1 Linkhub Mesh Wifi Ac1200 | 2026-06-17 | N/A | 9.8 CRITICAL |
| A denial of service vulnerability exists in the ucloud_del_node functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability. | |||||
| CVE-2022-26317 | 1 Mendix | 1 Mendix | 2026-06-17 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system. | |||||
| CVE-2022-26313 | 1 Mendix | 1 Forgot Password | 2026-06-17 | 6.8 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1). In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts. | |||||
| CVE-2022-26308 | 1 Pandorafms | 1 Pandora Fms | 2026-06-17 | N/A | 3.7 LOW |
| Pandora FMS v7.0NG.760 and below allows an improper access control in Configuration (Credential store) where a user with the role of Operator (Write) could create, delete, view existing keys which are outside the intended role. | |||||
| CVE-2022-26091 | 1 Google | 1 Android | 2026-06-17 | 4.6 MEDIUM | 5.7 MEDIUM |
| Improper access control vulnerability in Knox Manage prior to SMR Apr-2022 Release 1 allows that physical attackers can bypass Knox Manage using a function key of hardware keyboard. | |||||
| CVE-2022-25932 | 1 Inhandnetworks | 2 Inrouter302, Inrouter302 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| The firmware of InHand Networks InRouter302 V3.5.45 introduces fixes for TALOS-2022-1472 and TALOS-2022-1474. The fixes are incomplete. An attacker can still perform, respectively, a privilege escalation and an information disclosure vulnerability. | |||||
| CVE-2022-25831 | 1 Google | 1 Android | 2026-06-17 | 1.9 LOW | 2.0 LOW |
| Improper access control vulnerability in S Secure prior to SMR Apr-2022 Release 1 allows physical attackers to access secured data in certain conditions. | |||||
| CVE-2022-25824 | 1 Samsung | 1 Bixby Touch | 2026-06-17 | 2.1 LOW | 4.0 MEDIUM |
| Improper access control vulnerability in BixbyTouch prior to version 2.2.00.6 in China models allows untrusted applications to load arbitrary URL and local files in webview. | |||||
| CVE-2022-25755 | 1 Siemens | 48 Scalance X302-7eec, Scalance X302-7eec Firmware, Scalance X304-2fe and 45 more | 2026-06-17 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances. | |||||
| CVE-2022-25679 | 1 Qualcomm | 134 Aqt1000, Aqt1000 Firmware, Qca6390 and 131 more | 2026-06-17 | N/A | 6.2 MEDIUM |
| Denial of service in video due to improper access control in broadcast receivers in Snapdragon Compute, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Wearables | |||||
| CVE-2022-25650 | 1 Mendix | 1 Mendix | 2026-06-17 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.27), Mendix Applications using Mendix 8 (All versions < V8.18.14), Mendix Applications using Mendix 9 (All versions < V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field. | |||||
