Total
221 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-50948 | 1 Ibm | 1 Storage Fusion Hci | 2026-06-17 | N/A | 6.5 MEDIUM |
| IBM Storage Fusion HCI 2.1.0 through 2.6.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 275671. | |||||
| CVE-2023-49963 | 2026-06-17 | N/A | 8.8 HIGH | ||
| DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control. | |||||
| CVE-2023-46685 | 1 Level1 | 2 Wbr-6013, Wbr-6013 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| A hard-coded password vulnerability exists in the telnetd functionality of LevelOne WBR-6013 RER4_A_v3411b_2T2R_LEV_09_170623. A set of specially crafted network packets can lead to arbitrary command execution. | |||||
| CVE-2023-41713 | 1 Sonicwall | 61 Nsa2700, Nsa3700, Nsa4700 and 58 more | 2026-06-17 | N/A | 7.5 HIGH |
| SonicOS Use of Hard-coded Password vulnerability in the 'dynHandleBuyToolbar' demo function. | |||||
| CVE-2023-41030 | 1 Juplink | 2 Rx4-1500, Rx4-1500 Firmware | 2026-06-17 | 5.8 MEDIUM | 6.3 MEDIUM |
| Hard-coded credentials in Juplink RX4-1500 versions V1.0.2 through V1.0.5 allow unauthenticated attackers to log in to the web interface or telnet service as the 'user' user. | |||||
| CVE-2023-3237 | 1 Otcms | 1 Otcms | 2026-06-17 | 5.8 MEDIUM | 6.3 MEDIUM |
| A vulnerability classified as critical was found in OTCMS up to 6.62. This vulnerability affects unknown code. The manipulation of the argument username/password with the input admin leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-231508. | |||||
| CVE-2023-37231 | 1 Loftware | 1 Spectrum | 2026-06-17 | N/A | 9.8 CRITICAL |
| Loftware Spectrum before 4.6 HF14 uses a Hard-coded Password. | |||||
| CVE-2023-32145 | 1 Dlink | 4 Dap-1360, Dap-1360 Firmware, Dap-2020 and 1 more | 2026-06-17 | N/A | 8.8 HIGH |
| D-Link DAP-1360 Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DAP-1360 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of login requests to the web-based user interface. The firmware contains hard-coded default credentials. An attacker can leverage this vulnerability to bypass authentication on the system. . Was ZDI-CAN-18455. | |||||
| CVE-2023-2799 | 1 Cnoa Oa Project | 1 Cnoa Oa | 2026-06-17 | 5.8 MEDIUM | 6.3 MEDIUM |
| A vulnerability, which was classified as problematic, has been found in cnoa OA up to 5.1.1.5. Affected by this issue is some unknown functionality of the file /index.php?app=main&func=passport&action=login. The manipulation leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-229376. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2023-2645 | 1 Usr | 2 Usr-g806, Usr-g806 Firmware | 2026-06-17 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability, which was classified as critical, was found in USR USR-G806 1.0.41. Affected is an unknown function of the component Web Management Page. The manipulation of the argument username/password with the input root leads to use of hard-coded password. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. VDB-228774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2023-2061 | 1 Mitsubishielectric | 8 Fx5-enet\/ip, Fx5-enet\/ip Firmware, Rj71eip91 and 5 more | 2026-06-17 | N/A | 6.2 MEDIUM |
| Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP. | |||||
| CVE-2023-29103 | 1 Siemens | 4 6gk1411-1ac00, 6gk1411-1ac00 Firmware, 6gk1411-5ac00 and 1 more | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data. | |||||
| CVE-2023-28895 | 1 Preh | 2 Mib3, Mib3 Firmware | 2026-06-17 | N/A | 3.5 LOW |
| The password for access to the debugging console of the PoWer Controller chip (PWC) of the MIB3 infotainment is hard-coded in the firmware. The console allows attackers with physical access to the MIB3 unit to gain full control over the PWC chip. Vulnerability found on Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022. | |||||
| CVE-2023-23771 | 1 Motorola | 2 Mbts Base Radio, Mbts Base Radio Firmware | 2026-06-17 | N/A | 8.4 HIGH |
| Motorola MBTS Base Radio accepts hard-coded backdoor password. The Motorola MBTS Base Radio Man Machine Interface (MMI), allowing for service technicians to diagnose and configure the device, accepts a hard-coded backdoor password that cannot be changed or disabled. | |||||
| CVE-2023-23770 | 1 Motorola | 2 Mbts Site Controller, Mbts Site Controller Firmware | 2026-06-17 | N/A | 9.4 CRITICAL |
| Motorola MBTS Site Controller accepts hard-coded backdoor password. The Motorola MBTS Site Controller Man Machine Interface (MMI), allowing for service technicians to diagnose and configure the device, accepts a hard-coded backdoor password that cannot be changed or disabled. | |||||
| CVE-2023-1944 | 1 Kubernetes | 1 Minikube | 2026-06-17 | N/A | 8.4 HIGH |
| This vulnerability enables ssh access to minikube container using a default password. | |||||
| CVE-2023-0808 | 3 Bosswerk, Deyeinverter, Revolt-power | 6 Inverter, Inverter Firmware, Inverter and 3 more | 2026-06-17 | 3.7 LOW | 3.9 LOW |
| A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability. | |||||
| CVE-2022-45444 | 1 Sewio | 1 Real-time Location System Studio | 2026-06-17 | N/A | 10.0 CRITICAL |
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access. | |||||
| CVE-2022-41653 | 1 Daikinlatam | 2 Svmpc1, Svmpc2 | 2026-06-17 | N/A | 9.8 CRITICAL |
| Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system. | |||||
| CVE-2022-30271 | 1 Motorola | 2 Ace1000, Ace1000 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default. | |||||
