CVE-2019-10921 1 Siemens 2 Logo\!8 Bm, Logo\!8 Bm Firmware 2026-06-17 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known
CVE-2019-0072 1 Juniper 1 Sbr Carrier 2026-06-17 2.1 LOW 5.6 MEDIUM
An Unprotected Storage of Credentials vulnerability in the identity and access management certificate generation procedure allows a local attacker to gain access to confidential information. This issue affects: Juniper Networks SBR Carrier: 8.4.1 versions prior to 8.4.1R13; 8.5.0 versions prior to 8.5.0R4.
CVE-2019-0032 1 Juniper 2 Service Insight, Service Now 2026-06-17 2.1 LOW 7.8 HIGH
A password management issue exists where the Organization authentication username and password were stored in plaintext in log files. A locally authenticated attacker who is able to access these stored plaintext credentials can use them to login to the Organization. Affected products are: Juniper Networks Service Insight versions from 15.1R1, prior to 18.1R1. Service Now versions from 15.1R1, prior to 18.1R1.
CVE-2018-8851 1 Echelon 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more 2026-06-17 5.0 MEDIUM 9.8 CRITICAL
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.
CVE-2018-7515 1 Omron 1 Cx-supervisor 2026-06-17 4.6 MEDIUM 5.3 MEDIUM
In Omron CX-Supervisor Versions 3.30 and prior, access of uninitialized pointer vulnerabilities can be exploited when CX Supervisor indirectly calls an initialized pointer when parsing malformed packets.
CVE-2018-7510 1 Beaconmedaes 2 Scroll Medical Air Systems, Scroll Medical Air Systems Firmware 2026-06-17 5.0 MEDIUM 9.8 CRITICAL
In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication.
CVE-2018-25130 2026-06-17 N/A 6.2 MEDIUM
Beward Intercom 2.3.1 contains a credentials disclosure vulnerability that allows local attackers to access plain-text authentication credentials stored in an unencrypted database file. Attackers can read the BEWARD.INTERCOM.FDB file to extract usernames and passwords, enabling unauthorized access to IP cameras and door stations.
CVE-2017-9856 1 Sma 78 Sunny Boy 1.5, Sunny Boy 1.5 Firmware, Sunny Boy 2.5 and 75 more 2026-06-17 5.0 MEDIUM 3.4 LOW
An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
CVE-2017-7913 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2026-06-17 5.0 MEDIUM 9.8 CRITICAL
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.
CVE-2017-6049 1 3m 1 Detcon Sitewatch Gateway 2026-06-17 5.0 MEDIUM 7.5 HIGH
Detcon Sitewatch Gateway, all versions without cellular, an attacker can edit settings on the device using a specially crafted URL.
CVE-2017-16714 1 Iceqube 2 Thermal Management Center, Thermal Management Center Firmware 2026-06-17 5.0 MEDIUM 9.8 CRITICAL
In Ice Qube Thermal Management Center versions prior to version 4.13, passwords are stored in plaintext in a file that is accessible without authentication.