Vulnerabilities (CVE)

Filtered by CWE-121
Total 3795 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2026-5154 1 Tenda 2 Ch22, Ch22 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda CH22 1.0.0.1/1.If. The impacted element is the function fromSetCfm of the file /goform/setcfm of the component Parameter Handler. The manipulation of the argument funcname leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
CVE-2026-5152 1 Tenda 2 Ch22, Ch22 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was detected in Tenda CH22 1.0.0.1. Impacted is the function formCreateFileName of the file /goform/createFileName. Performing a manipulation of the argument fileNameMit results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
CVE-2026-5046 1 Tenda 2 Fh1201, Fh1201 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A flaw has been found in Tenda FH1201 1.2.0.14(408). Affected is the function formWrlExtraSet of the file /goform/WrlExtraSet of the component Parameter Handler. Executing a manipulation of the argument GO can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
CVE-2026-5045 1 Tenda 2 Fh1201, Fh1201 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was detected in Tenda FH1201 1.2.0.14(408). This impacts the function WrlclientSet of the file /goform/WrlclientSet of the component Parameter Handler. Performing a manipulation of the argument GO results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
CVE-2026-5044 1 Belkin 2 F9k1122, F9k1122 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A security vulnerability has been detected in Belkin F9K1122 1.00.33. This affects the function formSetSystemSettings of the file /goform/formSetSystemSettings of the component Setting Handler. Such manipulation of the argument webpage leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5043 1 Belkin 2 F9k1122, F9k1122 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A weakness has been identified in Belkin F9K1122 1.00.33. The impacted element is the function formSetPassword of the file /goform/formSetPassword of the component Parameter Handler. This manipulation of the argument webpage causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5042 1 Belkin 2 F9k1122, F9k1122 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A security flaw has been discovered in Belkin F9K1122 1.00.33. The affected element is the function formCrossBandSwitch of the file /goform/formCrossBandSwitch of the component Parameter Handler. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-5037 2026-06-17 1.7 LOW 3.3 LOW
A vulnerability was determined in mxml up to 4.0.4. This issue affects the function index_sort of the file mxml-index.c of the component mxmlIndexNew. Executing a manipulation of the argument tempr can lead to stack-based buffer overflow. The attack is restricted to local execution. The exploit has been publicly disclosed and may be utilized. This patch is called 6e27354466092a1ac65601e01ce6708710bb9fa5. A patch should be applied to remediate this issue.
CVE-2026-5036 1 Tenda 2 4g06, 4g06 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda 4G06 04.06.01.29. This vulnerability affects the function fromDhcpListClient of the file /goform/DhcpListClient of the component Endpoint. Performing a manipulation of the argument page results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used.
CVE-2026-5024 1 Dlink 2 Dir-513, Dir-513 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in D-Link DIR-513 1.10. This issue affects the function formSetEmail of the file /goform/formSetEmail. Performing a manipulation of the argument curTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2026-5021 1 Tenda 2 F453, F453 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A flaw has been found in Tenda F453 1.0.0.3. This affects the function fromPPTPUserSetting of the file /goform/PPTPUserSetting of the component httpd. This manipulation of the argument delno causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.
CVE-2026-5004 1 Wavlink 2 Wl-wn579x3-c, Wl-wn579x3-c Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was determined in Wavlink WL-WN579X3-C 231124. This impacts the function sub_4019FC of the file /cgi-bin/firewall.cgi of the component UPNP Handler. Executing a manipulation of the argument UpnpEnabled can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-4975 1 Tenda 2 Ac15, Ac15 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC15 15.03.05.19. This affects the function formSetCfm of the file /goform/setcfm of the component POST Request Handler. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2026-4974 1 Tenda 2 Ac7, Ac7 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CVE-2026-4961 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
CVE-2026-4960 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was determined in Tenda AC6 15.03.05.16. Affected is the function fromWizardHandle of the file /goform/WizardHandle of the component POST Request Handler. Executing a manipulation of the argument WANT/WANS can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2026-4906 1 Tenda 2 Ac5, Ac5 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was determined in Tenda AC5 15.03.06.47. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Executing a manipulation of the argument WANT/WANS can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2026-4905 1 Tenda 2 Ac5, Ac5 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC5 15.03.06.47. Impacted is the function formWifiWpsOOB of the file /goform/WifiWpsOOB of the component POST Request Handler. Performing a manipulation of the argument index results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.
CVE-2026-4904 1 Tenda 2 Ac5, Ac5 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC5 15.03.06.47. This issue affects the function formSetCfm of the file /goform/setcfm of the component POST Request Handler. Such manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2026-4903 1 Tenda 2 Ac5, Ac5 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A flaw has been found in Tenda AC5 15.03.06.47. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. This manipulation of the argument PPPOEPassword causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used.