Vulnerabilities (CVE)

Filtered by CWE-121
Total 4087 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-11048 1 Dlink 2 Di-8003, Di-8003 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-11047 1 Dlink 2 Di-8003, Di-8003 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10698 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10662 1 Tenda 2 Ac15, Ac15 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10661 1 Tenda 2 Ac15, Ac15 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10434 1 Tenda 2 Ac1206, Ac1206 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10351 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10283 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10282 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10281 1 Tenda 2 Rx9 Pro, Rx9 Pro Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10239 2026-06-17 N/A 7.2 HIGH
A security issue in the firmware image verification implementation at Supermicro MBD-X12DPG-OA6 . An attacker with administrator privileges can upload a specially crafted image, which can cause a stack overflow due to the unchecked fat->fsd.max_fld.
CVE-2024-10238 2026-06-17 N/A 7.2 HIGH
A security issue in the firmware image verification implementation at Supermicro MBD-X12DPG-OA6. An attacker can upload a specially crafted image that will cause a stack overflow is caused by not checking fld->used_bytes.
CVE-2024-10194 1 Wavlink 6 Wn530h4, Wn530h4 Firmware, Wn530hg4 and 3 more 2026-06-17 8.3 HIGH 8.8 HIGH
A vulnerability was found in WAVLINK WN530H4, WN530HG4 and WN572HG3 up to 20221028. It has been classified as critical. Affected is the function Goto_chidx of the file login.cgi of the component Front-End Authentication Page. The manipulation of the argument wlanUrl leads to stack-based buffer overflow. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-10130 1 Tenda 2 Ac8, Ac8 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-10123 1 Tenda 2 Ac8, Ac8 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0999 1 Totolink 2 N200re, N200re Firmware 2026-06-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Totolink N200RE 9.3.5u.6139_B20201216. It has been declared as critical. This vulnerability affects the function setParentalRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument eTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252268. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0998 1 Totolink 2 N200re, N200re Firmware 2026-06-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Totolink N200RE 9.3.5u.6139_B20201216. It has been classified as critical. This affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252267. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0997 1 Totolink 2 N200re, N200re Firmware 2026-06-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Totolink N200RE 9.3.5u.6139_B20201216 and classified as critical. Affected by this issue is the function setOpModeCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument pppoeUser leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252266 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0996 1 Tenda 2 I9, I9 Firmware 2026-06-17 8.3 HIGH 7.2 HIGH
A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0995 1 Tenda 2 W6, W6 Firmware 2026-06-17 8.3 HIGH 7.2 HIGH
A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.