Total
3797 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-2705 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2704 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2703 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. | |||||
| CVE-2024-2558 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2547 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2546 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2490 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2489 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2488 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2487 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-2486 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability. | |||||
| CVE-2024-2485 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-29756 | 1 Google | 1 Android | 2026-06-17 | N/A | 9.8 CRITICAL |
| In afe_callback of q6afe.c, there is a possible out of bounds write due to a buffer overflow. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | |||||
| CVE-2024-29421 | 2026-06-17 | N/A | 6.2 MEDIUM | ||
| xmedcon 0.23.0 and fixed in v.0.24.0 is vulnerable to Buffer Overflow via libs/dicom/basic.c which allows an attacker to execute arbitrary code. | |||||
| CVE-2024-29164 | 1 Hdfgroup | 1 Hdf5 | 2026-06-17 | N/A | 9.8 CRITICAL |
| HDF5 through 1.14.3 contains a stack buffer overflow in H5R__decode_heap, resulting in the corruption of the instruction pointer and causing denial of service or potential code execution. | |||||
| CVE-2024-29061 | 1 Microsoft | 13 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 10 more | 2026-06-17 | N/A | 7.8 HIGH |
| Secure Boot Security Feature Bypass Vulnerability | |||||
| CVE-2024-29045 | 1 Microsoft | 3 Ole Db Driver For Sql Server, Sql Server 2019, Sql Server 2022 | 2026-06-17 | N/A | 7.5 HIGH |
| Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability | |||||
| CVE-2024-29012 | 1 Sonicwall | 22 Nsa 2700, Nsa 3700, Nsa 4700 and 19 more | 2026-06-17 | N/A | 7.5 HIGH |
| Stack-based buffer overflow vulnerability in the SonicOS HTTP server allows an authenticated remote attacker to cause Denial of Service (DoS) via sscanf function. | |||||
| CVE-2024-28934 | 1 Microsoft | 5 Odbc Driver For Sql Server, Sql Server 2019, Sql Server 2022 and 2 more | 2026-06-17 | N/A | 8.8 HIGH |
| Microsoft ODBC Driver for SQL Server Remote Code Execution Vulnerability | |||||